Do Patient-Reported Outcomes Reflect Objective Measures of Function? Implications for Total Knee Arthroplasty

被引:3
|
作者
Hill, Brandon G. [1 ]
Ba, Shivesh Shah [2 ]
Moschetti, Wayne E. [1 ,2 ]
Schilling, Peter L. [1 ,2 ]
机构
[1] Dartmouth Hitchcock Med Ctr, 1 Med Ctr Dr, Lebanon, NH USA
[2] Geisel Sch Med, Dartmouth, NS, Canada
来源
JOURNAL OF ARTHROPLASTY | 2023年 / 38卷 / 07期
关键词
patient reported outcomes; standardized functional tests; functional outcomes; knee osteoarthritis; total knee arthroplasty; osteoarthritis initiative; ASSESS PHYSICAL FUNCTION; PERFORMANCE-BASED TESTS; TOTAL HIP; GAIT ANALYSIS; OSTEOARTHRITIS; PARAMETERS; PEOPLE;
D O I
10.1016/j.arth.2023.04.049
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patient-reported outcomes (PROs) are used in research, clinical practice, and by federal reimbursement models to assess outcomes for patients who have knee osteoarthritis (OA) and total knee arthroplasty (TKA). We examined a large cohort of patients to determine if commonly used PROs reflect observed evaluation as measured by standardized functional tests (SFTs). Methods: We used data from the Osteoarthritis Initiative, a 10-year observational study of knee osteoarthritis patients. Two cohorts were examined: 1) participants who received TKA (n = 281) and 2) participants who have native OA (n = 4,687). The PROs included Western Ontario and McMaster Osteoarthritis Index (WOMAC), Knee Injury and Osteoarthritis Outcome Score (KOOS), 12-Item Short Form Health Survey (SF-12), and Intermittent and Constant Pain Score (ICOAP). The SFTs included 20 m and 400 meter (m) walks and chair stand pace. Repeated measures correlation coefficients were used to determine the relationship between PROs and SFTs. Results: The PROs and SFTs were not strongly correlated in either cohort. The magnitude of the repeated measures correlation (rrm) between KOOS, WOMAC, SF-12, and ICOAP scores and SFT measurements in native knee OA patients ranged as follows: 400 m walk pace (0.08 to 0.20), chair stand pace (0.05 to 0.12), and 20 m pace (0.02 to 0.21), all with P <.05. In the TKA cohort, values ranged as follows: 400 M walk pace (0.00 to 0.29), chair stand time (0.02 to 0.23), and 20 M pace (0.03 to 0.30). Due to the smaller cohort size, the majority, but not all had P values < .05. Conclusion: There is not a strong association between PROs and SFTs among patients who have knee OA or among patients who received a TKA. Therefore, PROs should not be used as a simple proxy for observed evaluation of physical function. Rather, PROs and SFTs are complementary and should be used in combination for a more nuanced and complete characterization of outcome. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:S162 / +
页数:10
相关论文
共 50 条
  • [1] Patient-Reported Outcomes for Function and Pain in Total Knee Arthroplasty Patients
    Buus, Amanda A. O.
    Udsen, Flemming W.
    Laugesen, Britt
    El-Galaly, Anders
    Laursen, Mogens
    Hejlesen, Ole K.
    NURSING RESEARCH, 2022, 71 (05) : E39 - E47
  • [2] Implementation of Patient-reported Outcome Measures in Total Knee Arthroplasty
    Ayers, David C.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2017, 25 : S48 - S50
  • [3] Impact of Age on Patient-Reported Outcome Measures in Total Knee Arthroplasty
    Townsend, Luke A.
    Roubion, Ryan C.
    Bourgeois, Devin M.
    Leonardi, Claudia
    Fox, Rabun S.
    Dasa, Vinod
    Pollock, Grant R.
    JOURNAL OF KNEE SURGERY, 2018, 31 (06) : 580 - 584
  • [4] Early patient-reported outcomes versus objective function after total hip and knee arthroplasty A PROSPECTIVE COHORT STUDY
    Luna, I. E.
    Kehlet, H.
    Peterson, B.
    Wede, H. R.
    Hoevsgaard, S. J.
    Aasvang, E. K.
    BONE & JOINT JOURNAL, 2017, 99B (09): : 1167 - 1175
  • [5] Do Medial Pivot Kinematics Correlate With Patient-Reported Outcomes After Total Knee Arthroplasty?
    Warth, Lucian C.
    Ishmael, Marshall K.
    Deckard, Evan R.
    Ziemba-Davis, Mary
    Meneghini, R. Michael
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2411 - 2416
  • [6] Total Knee Arthroplasty Kinematics Predict Patient-Reported Outcome Measures: Implications for Clinical Kinematic Examinations
    Banks, Scott A.
    Catani, Fabio
    Deckard, Evan R.
    Mahoney, Ormonde M.
    Matsuda, Shuichi
    Meneghini, Robert M.
    Victor, Jan M. K.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (08): : S228 - S233
  • [7] Comparison of Responsiveness of Patient-Reported Outcome Measures After Total Knee Arthroplasty
    Vogel, Nicole
    Kaelin, Raphael
    Rychen, Thomas
    Wendelspiess, Severin
    Muller-Gerbl, Magdalena
    Arnold, Markus P.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (06): : 1487 - 1495.e2
  • [8] EVALUATING THE PERFORMANCE OF THREE ELECTRONIC PATIENT-REPORTED OUTCOMES (EPRO) MEASURES IN TOTAL KNEE ARTHROPLASTY (TKA)
    Palsgrove, A.
    VALUE IN HEALTH, 2019, 22 : S239 - S239
  • [9] Patient-reported outcome measures after total knee arthroplasty A SYSTEMATIC REVIEW
    Ramkumar, P. N.
    Harris, J. D.
    Noble, P. C.
    BONE & JOINT RESEARCH, 2015, 4 (07): : 120 - 127
  • [10] Impact of total knee arthroplasty for hemophilic arthropathy on patient-reported outcome measures
    Aydogdu, S.
    Kavakli, K.
    Bakan, O. M.
    Sahin, F.
    Bicer, E. K.
    Balkan, C.
    HAEMOPHILIA, 2019, 25 : 16 - 17