Measurement of gas holdup characteristics in two-phase column flotation by electrical capacitance volume tomography

被引:1
|
作者
Nugraha, Harisma [1 ,3 ]
Haryono, Didied [2 ,3 ]
Harjanto, Sri [1 ]
Huda, Mahfudz Al [3 ]
Taruno, Warsito P. [3 ]
机构
[1] Univ Indonesia, Dept Met & Mat Engn, Depok 16424, Indonesia
[2] Univ Sultan Ageng Tirtayasa, Dept Met Engn, Serang 42435, Indonesia
[3] CTECH Labs Edwar Technol, Ctr Nondestruct Testing & Proc Imaging, Tangerang 15235, Indonesia
关键词
ECVT; non-invasive; non-intrusive measurement; column flotation; flow pattern; two-phase system; RESISTANCE TOMOGRAPHY; BUBBLE-SIZE; DISPERSION; FLOW;
D O I
10.1088/1402-4896/ad008a
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Electrical capacitance volume tomography measured the gas holdup in two-phase column flotation. The purpose was to characterize gas holdup and understand its relation to flow patterns as a function of the types and doses of frothers. Experiments were conducted using laboratory-scale column flotation cells with dimensions of 5 x125 cm. The superficial gas velocities in the experiment were 0.5-4 cm s-1 with an interval of 0.5 cm/s. Methyl isobutyl carbinol (MIBC) and Oreprep F-583-OZ (Oreprep) were used as frothers at 5-40 ppm doses. The results showed that the difference between the lowest and highest gas holdup in the bubbly flow regime was similar to 0.07, and the transition from the bubbly to churn-turbulent flow occurred at a superficial gas velocity of 2 c m /s .
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Electrical Capacitance Volume Tomography Validation of Column Flotation Process with Gas Injection Variation
    Harjanto, Sri
    Haryono, Didied
    Faisal, Hermansyah Emir
    Daniah, Kholis
    Nugraha, Harisma
    Al Huda, Mahfudz
    Taruno, Warsito P.
    ENGINEERING JOURNAL-THAILAND, 2018, 22 (01): : 215 - 227
  • [2] The measurement of gas solid two-phase flow parameters based on electrical capacitance tomography technology
    Tian H.
    Zhou Y.
    Yang T.
    Zhao Y.
    International Journal of Networking and Virtual Organisations, 2019, 20 (01): : 1 - 13
  • [3] Column Flotation Monitoring Based on Electrical Capacitance Volume Tomography: A Preliminary Study
    Haryono, Didied
    Harjanto, Sri
    Nugraha, Harisma
    Al Huda, Mahfudz
    Taruno, Warsito Purwo
    PROCEEDINGS OF THE 1ST INTERNATIONAL PROCESS METALLURGY CONFERENCE (IPMC 2016), 2017, 1805
  • [4] Voidage measurement of oil-gas two-phase flow using electrical capacitance tomography technique
    Wang, Wei-Wei
    Wang, Bao-Liang
    Huang, Zhi-Yao
    Li, Hai-Qing
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 2006, 20 (04): : 515 - 519
  • [5] MEASUREMENT OF RADIAL GAS HOLDUP PROFILES IN A FLOTATION COLUMN
    XU, MQ
    FINCH, JA
    HULS, BJ
    INTERNATIONAL JOURNAL OF MINERAL PROCESSING, 1992, 36 (3-4) : 229 - 244
  • [6] The investigation of gas holdup distribution in a two-phase bubble column using ultrasonic computed tomography
    Supardan, Muhammad Dani
    Masuda, Yoshifumi
    Maezawa, Akinori
    Uchida, Shigeo
    CHEMICAL ENGINEERING JOURNAL, 2007, 130 (2-3) : 125 - 133
  • [7] Two-phase Flow Parameters Measurement and Image Reconstruction for Electrical Capacitance Tomography
    Chen Yu
    Zhang Lifeng
    Chen Deyun
    2008 INTERNATIONAL WORKSHOP ON EDUCATION TECHNOLOGY AND TRAINING AND 2008 INTERNATIONAL WORKSHOP ON GEOSCIENCE AND REMOTE SENSING, VOL 2, PROCEEDINGS,, 2009, : 680 - 684
  • [8] Application of electrical capacitance tomography to the void fraction measurement of two-phase flow
    Huang, ZY
    Wang, BL
    Li, HQ
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 341 - 345
  • [9] Application of electrical capacitance tomography to the void fraction measurement of two-phase flow
    Huang, ZY
    Wang, BL
    Li, HQ
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2003, 52 (01) : 7 - 12
  • [10] Gas holdup characteristics in a flotation column with different solids
    Bhunia, Kamalendu
    Kundu, Gautam
    Mukherjee, Dibyendu
    SEPARATION SCIENCE AND TECHNOLOGY, 2017, 52 (07) : 1298 - 1309