The effect of subscapularis repair in reverse total shoulder arthroplasty depends on the design of the implant: a comparative study with a minimum 2-year follow-up

被引:0
|
作者
Mocini, Fabrizio [1 ]
Cerciello, Simone [1 ,2 ]
Corona, Katia [3 ]
Morris, Brent J. [4 ]
Saturnino, Luca [1 ]
Giordano, Matthew C. [1 ]
机构
[1] Casa Cura Villa Betania, Rome, Italy
[2] Catholic Univ, A Gemelli Univ Hosp Fdn IRCCS, Rome, Italy
[3] Univ Molise, Dept Med & Hlth Sci Vincenzo Tiberio, Campobasso, Italy
[4] Baptist Hlth Med Grp Orthoped & Sports Med, Lexington, KY USA
关键词
Reverse shoulder arthroplasty; Subscapularis repair; Medialized design; Lateralized design; Neck-shaft angle; Scapular notching; OUTCOMES; CUFF; COMPLICATIONS; PROSTHESIS; REOPERATIONS; DISLOCATION; ARTHRITIS; REVISIONS;
D O I
10.1007/s00402-023-05025-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionThe role of the subscapularis (Ssc) tendon does not yet have a well-defined role in RSA. The purpose of the present study was to evaluate if the repair of the Ssc in RSA improves overall clinical and radiographic results and if it has the same results using a medialized design humeral stem compared to a lateralized design.MethodsEighty-four consecutive patients undergoing RSA were retrospectively analyzed. Nine patients were lost at FU. Two implants with similar glenosphere design and different stem design (medialized and lateralized) were used. The Ssc was repaired in case of good quality of the fibers and reducibility without tension intraoperatively. Patients were divided into four groups for data analysis depending on whether they had received a medialized or lateralized design and Ssc repair or not. Patients were reviewed at an average follow-up of 40.8 & PLUSMN; 13.1 months. Clinical outcome measures included Active range of motion (ROM), strength, visual analog scale (VAS), Constant-Murley score (CMS), and the American Shoulder and Elbow Surgeons score (ASES). Radiographic evaluation at final follow-up was performed to assess scapular notching, stress shielding, and radiolucent lines.ResultsNo statistically significant clinical differences (p > 0.05) emerged between Lat/Ssc+ and Lat/Ssc-. Conversely, the patients belonging to the Med/Ssc- group reported statistically worse (p < 0.05) results than the Med/Ssc + group in terms of VAS, ASES and CMS. Statistically worse (p < .05) results in the Med/Ssc- group than in the Med/Ssc + were found also in active ROM achieved in FE, ABD, ER1 and ER2, and in the strength obtained in FE, ABD and ER2. Scapular notching was reported in 3 shoulders (15.7%) in Lat/Ssc+ group and in 7 shoulders (50%) in Lat/Ssc- group, while it was reported in 4 shoulders (14.2%) in Med/Ssc + group and in 6 shoulders (42.8%) in Med/Ssc- group. Stress shielding was observed in 6 cases in Lat/Ssc+ group (31.6%), in 8 cases in Lat/Ssc- group (57.1%), in 3 cases (10.7%) in Med/Ssc + group and 4 cases in Med/Ssc- group (28.6%).ConclusionsPatients undergoing RSA show clinical improvements at mid-term follow-up with a low rate of complications, regardless of the use of a medialized or a lateralized humeral stem design. Ssc repair is associated with better functional outcomes in the cohort of medialized stem, while it did not yield significant differences in the cohort of lateralized stem.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 50 条
  • [1] The effect of subscapularis repair in reverse total shoulder arthroplasty depends on the design of the implant: a comparative study with a minimum 2-year follow-up
    Fabrizio Mocini
    Simone Cerciello
    Katia Corona
    Brent J. Morris
    Luca Saturnino
    Matthew C. Giordano
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 41 - 49
  • [2] The radiographic and clinical outcomes of stemless reverse total shoulder arthroplasty: a minimum 2-year follow-up study
    Choi, Chang-Hyuk
    Choi, Ji Hoon
    Che, Sug Hun
    Kim, Jun-Young
    CLINICS IN SHOULDER AND ELBOW, 2024, 27 (04): : 428 - 436
  • [3] Comparative study of total shoulder arthroplasty versus total shoulder surface replacement for glenohumeral osteoarthritis with minimum 2-year follow-up
    Kooistra, Bauke W.
    Willems, W. Jaap
    Lemmens, Eelke
    Hartel, Bas P.
    van den Bekerom, Michel P. J.
    van Deurzen, Derek F. P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (03) : 430 - 436
  • [4] Results of total shoulder arthroplasty with a monoblock porous tantalum glenoid component: a prospective minimum 2-year follow-up study
    Budge, Matthew D.
    Nolan, Elizabeth M.
    Heisey, Meredith H.
    Baker, Kevin
    Wiater, J. Michael
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (04) : 535 - 541
  • [5] Minimum two-year follow-up of a reverse total shoulder arthroplasty using a wedged baseplate
    Parker, Simon J. M.
    Bell, Simon N.
    Wiemer, Feoline
    Coghlan, Jennifer A.
    Clitherow, Harry D.
    Rayment, Helen M.
    SHOULDER & ELBOW, 2024,
  • [6] Neck shaft angle in reverse shoulder arthroplasty: 135 vs. 145 degrees at minimum 2-year follow-up
    Neyton, Lionel
    Nigues, Ana
    McBride, Andrew P.
    de Sanctis, Edoardo Giovannetti
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (07) : 1486 - 1493
  • [7] Outcomes of Meniscal Repair Minimum of 2-Year Follow-Up
    Tuckman, David V.
    Bravman, Jonathan T.
    Lee, Susan S.
    Rosen, Jeffrey E.
    Sherman, Orrin H.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2006, 63 (3-4): : 100 - 104
  • [8] Arthroscopic treatment of multidirectional shoulder instability with minimum 270° labral repair:: Minimum 2-year follow-up
    Alpert, Joshua M.
    Verma, Nikhil
    Wysocki, Robert
    Yanke, Adam B.
    Romeo, Anthony A.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (06): : 704 - 711
  • [9] Electrothermal arthroscopic shoulder capsulorrhaphy - A minimum 2-year follow-up
    Hawkins, Richard J.
    Krishnan, Sumant G.
    Karas, Spero G.
    Noonan, Thomas J.
    Horan, Marilee P.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (09): : 1484 - 1488
  • [10] Clinical Outcomes Following Revision Total Knee Arthroplasty: Minimum 2-Year Follow-up
    Quinn, Jonathan
    Jones, Peter
    Randle, Ray
    CLINICS IN ORTHOPEDIC SURGERY, 2022, 14 (01) : 69 - 75