A comparison of Atrial Fibrillation Detection Strategies After Ischemic Stroke-A Retrospective Study

被引:1
|
作者
Salehin, Salman [1 ,6 ]
Muhammad, Saleh [2 ]
Rasmussen, Peter [1 ]
Mai, Steven [1 ]
Safder, Zaid [1 ]
Hasan, Syed M. [2 ]
Ghani, Hafiz A. [3 ]
Zhang, Yuanyi [4 ]
Salehin, Shahran [5 ]
Kuo, Yong -Fang [4 ]
Chatila, Khaled [2 ]
Khalife, Wissam [2 ]
Sewani, Asif [2 ]
机构
[1] Univ Texas Med Branch, Dept Internal Med, Galveston, TX USA
[2] Univ Texas Med Branch, Dept Cardiol, Galveston, TX USA
[3] Univ Texas Med Branch, Dept Pathol, Galveston, TX USA
[4] Univ Texas Med Branch, Dept Biostat, Galveston, TX USA
[5] Holy Family Red Crescent Med Coll Hosp, Sch Med, Dhaka, Bangladesh
[6] Univ Texas Med Branch, Dept Internal Med, 301 Univ Blvd, Galveston, TX 77555 USA
关键词
GUIDELINES; MANAGEMENT; RECURRENCE; CARE;
D O I
10.1016/j.cpcardiol.2022.101515
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective of this retrospective study was to determine if long-term continuous cardiac monitoring with Implantable loop recorder (ILR) in patients with Cryptogenic strokes or TIA is superior at detecting Atrial Fibrillation (AF) than 30-day Event Monitor (EM) and 48-hour Holter Monitor (HM). Further-more, we aimed to deduce if uncovering AF leads to lower risk of future ischemic strokes, or reduction in mortality. In 20%-30% cases, the cause of stroke remained unexplained after diagnostic workup which has led to coining of the term, Cryptogenic Stroke (CS). Undiagnosed AF is a prime suspect in CS, but guidelines do not recommend initiation of anticoagulation unless AF has formally been detected. IRB approved retrospective study included patients with at least 1 episode of ischemic stroke or TIA with-out identifiable cause and was monitored with either HM, EM or ILR to diagnose any undiscovered AF. All patients (n = 531) had at least 1 year, and up to 3 years, of follow-up after device placement. Chi-Squared anal-ysis and Multivariable logistic regression demonstrated no statistically significant difference among 3 devices for detection of AF within 1 month of index stroke but a significant difference in AF detection was observed at 6, 12 and 24 months. Cox proportional hazard model showed device type had no significant impact on sec-ondary outcomes: Subsequent ischemic stroke or TIA, Initiation of anticoagulation, Mortality and Incidence of major bleeding. Despite the superiority of AF detec-tion by ILR, it is not superior to HM or EM in lowering the risk of subsequent stroke or TIA, or in reducing mortality. (Curr Probl Cardiol 2023;48:101515.)
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Comment on: "A comparison of Atrial Fibrillation Detection Strategies After lschemic Stroke-A Retrospective Study"
    Rafiq, Youmna
    Imran, Laiba
    Ansari, Zobia
    CURRENT PROBLEMS IN CARDIOLOGY, 2023, 48 (12)
  • [2] A Comparison of Atrial Fibrillation Detection Strategies After Ischemic Stroke- A Retrospective Study
    Salehin, Salman
    Saleh, Mohammed
    Rasmussen, Peter
    Mai, Steven
    Safder, Zaid
    Hasan, Syed
    Chatila, Khaled
    Khalife, Wissam
    Sewani, Asif
    CIRCULATION, 2022, 146
  • [3] Delayed Detection of Atrial Fibrillation after Ischemic Stroke
    Kamel, Hooman
    Lees, Kennedy R.
    Lyden, Patrick D.
    Teal, Philip A.
    Shuaib, Ashfaq
    Ali, Myzoon
    Johnston, S. Claiborne
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2009, 18 (06): : 453 - 457
  • [4] Atrial Fibrillation Detection and Ischemic Stroke Recurrence in Cryptogenic Stroke: A Retrospective, Multicenter, Observational Study
    Todo, Kenichi
    Okazaki, Shuhei
    Doijiri, Ryosuke
    Yamazaki, Hidekazu
    Sonoda, Kazutaka
    Koge, Junpei
    Iwata, Tomonori
    Ueno, Yuji
    Yamagami, Hiroshi
    Kimura, Naoto
    Morimoto, Masafumi
    Kondo, Daisuke
    Koga, Masatoshi
    Nagata, Eiichiro
    Miyamoto, Nobukazu
    Kimura, Yoko
    Gon, Yasufumi
    Sasaki, Tsutomu
    Mochizuki, Hideki
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2024, 13 (03):
  • [5] Delayed Detection Of Atrial Fibrillation After Ischemic Stroke Or Transient Ischemic Attack
    Zurru, Maria C.
    Brescacin, Laura
    Alonzo, Claudia
    Villarroel, Victor
    Orzuza, Gabriela
    Camera, Luis
    Waisman, Gabriel
    Cristiano, Edgardo
    STROKE, 2013, 44 (02)
  • [6] Telemetric Monitoring for the Detection of Atrial Fibrillation after Acute Ischemic Stroke
    Sposato, Luciano A.
    Jauregui, Agustin
    Calle, Analia
    Pontello, Noelia
    Klin, Pablo
    Zamora, Rafael
    Klein, Francisco
    STROKE, 2009, 40 (04) : E239 - E239
  • [7] Telemetric Monitoring for the Detection of Atrial Fibrillation after Acute Ischemic Stroke
    Jauregui, Agustin
    Ferrua, Marisol
    Pontello, Noelia
    Klin, Pablo
    Zamora, Rafael
    Klein, Francisco
    Sposato, Luciano A.
    NEUROLOGY, 2009, 72 (11) : A47 - A47
  • [8] Expert opinion paper on atrial fibrillation detection after ischemic stroke
    Haeusler, Karl Georg
    Groeschel, Klaus
    Koehrmann, Martin
    Anker, Stefan D.
    Brachmann, Johannes
    Boehm, Michael
    Diener, Hans-Christoph
    Doehner, Wolfram
    Endres, Matthias
    Gerloff, Christian
    Huttner, Hagen B.
    Kaps, Manfred
    Kirchhof, Paulus
    Nabavi, Darius Guenther
    Nolte, Christian H.
    Pfeilschifter, Waltraud
    Pieske, Burkert
    Poli, Sven
    Schaebitz, Wolf Ruediger
    Thomalla, Goetz
    Veltkamp, Roland
    Steiner, Thorsten
    Laufs, Ulrich
    Roether, Joachim
    Wachter, Rolf
    Schnabel, Renate
    CLINICAL RESEARCH IN CARDIOLOGY, 2018, 107 (10) : 871 - 880
  • [9] Expert opinion paper on atrial fibrillation detection after ischemic stroke
    Karl Georg Haeusler
    Klaus Gröschel
    Martin Köhrmann
    Stefan D. Anker
    Johannes Brachmann
    Michael Böhm
    Hans-Christoph Diener
    Wolfram Doehner
    Matthias Endres
    Christian Gerloff
    Hagen B. Huttner
    Manfred Kaps
    Paulus Kirchhof
    Darius Günther Nabavi
    Christian H. Nolte
    Waltraud Pfeilschifter
    Burkert Pieske
    Sven Poli
    Wolf Rüdiger Schäbitz
    Götz Thomalla
    Roland Veltkamp
    Thorsten Steiner
    Ulrich Laufs
    Joachim Röther
    Rolf Wachter
    Renate Schnabel
    Clinical Research in Cardiology, 2018, 107 : 871 - 880
  • [10] COST COMPARISON OF AMBULATORY MONITORING STRATEGIES FOR THE DETECTION OF ATRIAL FIBRILLATION AFTER EMBOLIC STROKE OF UNKNOWN SOURCE AND CRYPTOGENIC TRANSIENT ISCHEMIC ATTACK
    Klinkhammer, Brent
    Simons, Grant R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 193 - 193