Energy Performance Comparison of a Chiller Plant Using the Conventional Staging and the Co-Design Approach in the Early Design Phase of Hotel Buildings

被引:2
|
作者
Torres, Yamile Diaz [1 ]
Gullo, Paride [2 ]
Herrera, Hernan Hernandez [3 ]
del Toro, Migdalia Torres [4 ]
Calvo, Roy Reyes [5 ]
Ortega, Jorge Ivan Silva [6 ]
Sarduy, Julio Gomez [5 ]
机构
[1] Inst Super Politecn Tecnol & Ciencias ISPTEC, Dept Engn & Tecnol, Ave Luanda Sul,POB 583, Luanda, Angola
[2] Univ Southern Denmark SDU, Dept Mech & Elect Engn, DK-6400 Sonderborg, Denmark
[3] Univ Simon Bolivar, Fac Engn, Barranquilla 080005, Colombia
[4] Inst Super Politecn Alvorecer Juventude ISPAJ, Dept Engn & Ciencias Exactas, Urbanicao Nova Vida,Rua 45 Kilamba Kiaxi,POB 583, Luanda, Angola
[5] Univ Carlos Rafael Rodriguez, Studies Ctr Energy & Environm, Cienfuegos 55100, Cuba
[6] Univ Costa, Dept Energy, Barranquilla 080005, Colombia
关键词
chiller plant; co-design; traditional staging; optimal chiller loading; optimal chiller sequencing; ROBUST OPTIMAL-DESIGN; COOLING LOAD UNCERTAINTY; WATER-SYSTEM; OPTIMIZATION; OPERATION; SIMULATION; MODEL;
D O I
10.3390/en16093782
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As part of the design process of a chiller plant, one of the final stages is the energy testing of the system in relation to future operating conditions. Recent studies have suggested establishing robust solutions, but a conservative approach still prevails at this stage. However, the results of some recent studies suggest the application of a new co-design (control-design) approach. The present research involves a comparative analysis between the use of conventional staging and the co-design approach in the design phase of a chiller plant. This paper analyzes the energy consumption estimations of six different chiller plant combinations for a Cuban hotel. For the conservative approach using on/off traditional staging, the results suggest that the best option would be the adoption of a chiller plant featuring a symmetrical configuration. However, the outcomes related to the co-design approach suggest that the best option would be an asymmetrical configuration. The energy savings results were equal to 24.8% and the resulting coefficient of performance (COP) was 59.7% greater than that of the symmetrical configuration. This research lays firm foundations for the correct choice and design of a suitable chiller plant configuration for a selected hotel, allowing for significant energy savings in the tourism sector.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Control co-design of commercial building chiller plant using Bayesian optimization
    Bhattacharya, Arnab
    Vasisht, Soumya
    Adetola, Veronica
    Huang, Sen
    Sharma, Himanshu
    Vrabie, Draguna L.
    ENERGY AND BUILDINGS, 2021, 246
  • [2] The integrated care performance assessment tool: a co-design approach
    Dates, Mariana
    Tedeschi, Micol
    Lennox-Chhugani, Niamh
    INTERNATIONAL JOURNAL OF INTEGRATED CARE, 2019, 19
  • [3] Automated Design of CRLH Structures using Co-Design Synthesis Computational Approach
    Siragusa, R.
    Nguyen, H. V.
    Perret, E.
    Lemaitre-Auger, P.
    Tedjini, S.
    Caloz, C.
    APMC: 2009 ASIA PACIFIC MICROWAVE CONFERENCE, VOLS 1-5, 2009, : 830 - +
  • [4] A Gradient-based Approach for Optimal Plant Controller Co-Design
    Wang, Yuh-Shyang
    Wang, Yebin
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 3249 - 3254
  • [5] THE COMPARISON OF THE ENERGY PERFORMANCE OF HOTEL BUILDINGS USING PROMETHEE DECISION-MAKING METHOD
    Vujosevic, Milica L.
    Popovic, Milena J.
    THERMAL SCIENCE, 2016, 20 (01): : 197 - 208
  • [6] Co-design of a wave energy converter using constrained predictive control
    O'Sullivan, Adrian C. M.
    Lightbody, Gordon
    RENEWABLE ENERGY, 2017, 102 : 142 - 156
  • [7] In-situ co-design of Mobile Games using Design Thinking's resources approach
    Challiol, Cecilia
    Borrelli, Franco M.
    Goin Plexevi, Francisco
    Rouaux Servat, Candela M.
    Mendiburu, Facundo, I
    Gomez-Torres, Estevan
    Gordillo, Silvia E.
    ENFOQUE UTE, 2020, 11 (01): : 1 - 14
  • [8] A Co-Design Approach for Hardware Optimizations in Multicore Architectures using MCAPI
    da Rosa, T. Raupp
    Lemaire, R.
    Clermidy, F.
    2015 NINTH INTERNATIONAL WORKSHOP ON INTERCONNECTION NETWORK ARCHITECTURES: ON-CHIP, MULTI-CHIP (INA-OCMC), 2015, : 17 - 20
  • [9] PHEV powertrain co-design with vehicle performance considerations using MDSDO
    Azad, Saeed
    Behtash, Mohammad
    Houshmand, Arian
    Alexander-Ramos, Michael J.
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2019, 60 (03) : 1155 - 1169
  • [10] PHEV powertrain co-design with vehicle performance considerations using MDSDO
    Saeed Azad
    Mohammad Behtash
    Arian Houshmand
    Michael J. Alexander-Ramos
    Structural and Multidisciplinary Optimization, 2019, 60 : 1155 - 1169