A sensitive electrochemical nanosensor based on iron oxide nanoparticles and multiwalled carbon nanotubes for simultaneous determination of benzoquinone and catechol in groundwater

被引:8
|
作者
Sawczuk, Raquel B. S. [1 ,2 ]
Pinheiro, Helilma A. [3 ]
Santos, Jose Ribamar N. [3 ]
Alves, Ismael C. B. [3 ]
Viegas, Helmara D. C. [4 ]
Lacerda, Cristina A. [4 ]
Sousa, Janyeid Karla C. [5 ]
Marques, Edmar P. [4 ]
Marques, Aldalea L. B. [1 ,2 ]
机构
[1] Fed Univ Maranhao UFMA, Dept Chem Technol, Nucl Studies Petr & Energy NEPE, LPQA, Sao Luis, Maranhao, Brazil
[2] Fed Univ Maranhao UFMA, Dept Chem Technol, LAPQAP, Sao Luis, Maranhao, Brazil
[3] Fed Univ Maranhao UFMA, Dept Chem Technol, Postgrad Program Biodivers & Biotechnol BIONORTE, Sao Luis, Maranhao, Brazil
[4] State Univ Maranhao UEMA, Chem Dept, Sao Luis, Maranhao, Brazil
[5] Univ Fed Maranhao, Dept Sci & Technol, Sao Luis, Maranhao, Brazil
关键词
Benzene derivatives; iron oxide nanoparticles; carbon nanotubes; underground water; glassy carbon electrode; PASTE ELECTRODE; GRAPHENE OXIDE; HYDROQUINONE; WATER; SENSOR; SURFACTANT; FABRICATION; PHENOL; ANODE; FILM;
D O I
10.1080/03067319.2021.1882446
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Benzoquinone (BQ, 1,4-dihydroxybenzene) and catechol (CC, 1,2-dihydroxybenzene) are considered as emerging microcontaminants due to their persistent toxicity for plants and animals. Therefore, it is of great importance to monitor these contaminants in groundwater. This work proposes a novel sensor based on a multiwalled carbon nanotubes functionalised with carbonyls, and iron oxide nanoparticles (MWCNT-COOH/Fe2O3) for simultaneous determination of BQ and CC. The nanomaterials were characterised by Infrared Spectroscopy (FT-IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and Cyclic Voltammetry (CV). The electrochemical determination of BQ and CC has been studied using differential pulse voltammetry (DPV) technique on glassy carbon electrode (GCE) modified with MWCNT-COOH/Fe2O3 nanocomposite (MWCNT-COOH/Fe2O3/GCE). The developed new method under optimised experimental conditions was applied successfully for the simultaneous determination of BQ and CC in spiked underground water sample, pH 5.0 (Britton Robson - BR buffer). For DPV measurements, the following parameters were used after optimisation: E-initial = 0.0 V, E-final = 0.40 V; scan rate = 0.01 V s(-1) and pulse amplitude = 0.07 V. The linearity range of both analytes BQ and CC was 8-100 mu mol L-1 with limits of detection (DLs) of 3.46 mu mol L-1 and 1.52 mu mol L-1, respectively. Good average results of recovery (n = 3) were obtained in spiked environmental samples for BQ (sample 1: 98.16%; sample 2: 100.55%) and CC (sample 1: 97.44%; sample 2: 97.84%), with precision (relative standard deviation) of 4.5% and 5.6%, respectively.
引用
收藏
页码:1733 / 1750
页数:18
相关论文
共 50 条
  • [1] An electrochemical sensor based on titanium oxide–carbon nanotubes nanocomposite for simultaneous determination of hydroquinone and catechol
    Zuchao Meng
    Hongfang Zhang
    Jianbin Zheng
    Research on Chemical Intermediates, 2015, 41 : 3135 - 3146
  • [2] An electrochemical sensor based on titanium oxide-carbon nanotubes nanocomposite for simultaneous determination of hydroquinone and catechol
    Meng, Zuchao
    Zhang, Hongfang
    Zheng, Jianbin
    RESEARCH ON CHEMICAL INTERMEDIATES, 2015, 41 (05) : 3135 - 3146
  • [3] Highly Sensitive Carbon Based Sensors Using Zinc Oxide Nanoparticles Immobilized Multiwalled Carbon Nanotubes for Simultaneous Determination of Desvenlafaxine Succinate and Clonazepam
    Rizk, Mohamed
    Taha, Elham Anwer
    Abou El-Alamin, Maha Mahmoud
    Hendawy, Hassan A. M.
    Sayed, Yasmine Mohamed
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (07) : H333 - H341
  • [4] Electrochemical Sensor Design Based on Silver Nanoparticles Modified Multiwalled Carbon Nanotubes Paste Electrode for the Sensitive Determination of Mepivacaine
    Demir, Ersin
    Silah, Hulya
    Erkmen, Cem
    Uslu, Bengi
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2023, 26 (15) : 2644 - 2655
  • [5] Decoration of Covalent Polyoxometalate-Organic Frameworks with Pt Nanoparticles and Multiwalled Carbon Nanotubes for Simultaneous Electrochemical Detection of Hydroquinone and Catechol
    Li, Na
    Huang, Jing-Ru
    Zhang, Hong-Yue
    Cui, Min
    Sun, Bao
    Zhang, Cong
    Zhao, Hai-Yan
    ACS APPLIED NANO MATERIALS, 2024, 7 (02) : 1960 - 1969
  • [6] Electrochemical Determination of Catechol Using Functionalized Multiwalled Carbon Nanotubes modified Screen Printed Carbon Electrode
    Rao, Mettu Mallikarjuna
    Settu, Ramki
    Chen, Shen-Ming
    Alagarsamy, Periyalagan
    Chen, Tse-Wei
    Hong, In-Seok
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (06): : 6126 - 6134
  • [7] Electrochemical sensor for simultaneous determination of trifluoperazine and dopamine in human serum based on graphene oxide-carbon nanotubes/iron-nickel nanoparticles
    Ahmed, Yousef M.
    Eldin, Mahmoud A.
    Galal, Ahmed
    Atta, Nada F.
    RSC ADVANCES, 2023, 13 (36) : 25209 - 25217
  • [8] An Ultrasensitive Electrochemical Sensor Based on Multiwalled Carbon Nanotube@Reduced Graphene Oxide Nanoribbon Composite for Simultaneous Determination of Hydroquinone, Catechol and Resorcinol
    Yang, Siyi
    Yang, Mei
    Liu, Qingyan
    Wang, Xiaojing
    Fa, Huanbao
    Wang, Yongzhong
    Hou, Changjun
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) : B547 - B553
  • [9] Simultaneous electrochemical determination of dopamine and paracetamol on multiwalled carbon nanotubes/graphene oxide nanocomposite-modified glassy carbon electrode
    Cheemalapati, Srikanth
    Palanisamy, Selvakumar
    Mani, Veerappan
    Chen, Shen-Ming
    TALANTA, 2013, 117 : 297 - 304
  • [10] Development of an electrochemical sensor for the determination of glycerol based on glassy carbon electrodes modified with a copper oxide nanoparticles/multiwalled carbon nanotubes/pectin composite
    Javier Arevalo, Fernando
    Osuna-Sanchez, Yolanda
    Sandoval-Cortes, Jose
    Di Tocco, Aylen
    Marcelo Granero, Adrian
    Noel Robledo, Sebastian
    Alicia Zon, Maria
    Roberto Vettorazzi, Nelio
    Luis Martinez, Jose
    Patricia Segura, Elda
    Ilina, Anna
    Fernandez, Hector
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 244 : 949 - 957