Titanium modular stems in total hip arthroplasty due to developmental dysplasia: a registry comparison with single-taper implants

被引:4
|
作者
Castagnini, Francesco [1 ]
Cosentino, Monica [2 ]
Bordini, Barbara [2 ]
Montalti, Maurizio [1 ]
Biondi, Federico [1 ]
Faldini, Cesare [3 ,4 ]
Traina, Francesco [1 ,4 ]
机构
[1] IRCCS Ist Ortoped Rizzoli, Orthopaed Traumatol & Prosthet Surg & Revis Hip &, Via Pupilli 1, I-40136 Bologna, Italy
[2] IRCCS Ist Ortoped Rizzoli, Med Technol Lab, Bologna, Italy
[3] IRCCS Ist Ortoped Rizzoli, Orthopaed & Traumatol Clin 1, Bologna, Italy
[4] Univ Bologna, Bologna, Italy
关键词
Aseptic loosening; corrosion; dislocation; dual taper; exchangeable neck; failure; SUBTROCHANTERIC SHORTENING OSTEOTOMY; FEMORAL-NECK; REPLACEMENT; COMPONENT;
D O I
10.1177/11207000221124115
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: The routine use of proximal femoral modularity was discouraged in total hip arthroplasties (THAs). However, titanium dual-taper (DT) implants may provide some advantages over single-taper (ST) stems in cases of complex deformity. A registry study comparing ST and DT stems in dysplasia was designed, aiming to assess: (1) survival rates at long-term; (2) reasons for revision; (3) the profile of failed implants. Methods: The arthroplasty registry RIPO was investigated for cementless THAs performed for dysplasia since 2000. ST implants were compared to titanium-on-titanium DT stems. Demographics and implant features were collected. Survival rates and reasons for revision were compared. The profile of DT stem failures in dysplasia was defined. Results: 6429 implants were included in the study, 3642 ST and 2787 DT. The demographic and implant features of the 2 cohorts were not comparable. The DT cohort achieved higher survival rates at long-term (93.9% vs. 91.6%, p = 0.018). DT implants showed a higher rate of implant breakage (0.6%, p = 0.011) and a lower rate of aseptic loosening (p = 0.005). There were no differences in terms of revisions for dislocation. No metallosis occurred. There were more revisions in DT implants in males <65 years, with a 28-mm head size or smaller. Conclusions: Modularity did not result in lower survival rates in dysplastic patients and may even reduce the rate of aseptic loosening in comparison to ST stems. The rate of implant breakage is not negligible. Younger males are not good candidates for titanium DT stems.
引用
收藏
页码:916 / 924
页数:9
相关论文
共 50 条
  • [1] Single-taper conical tapered stem in total hip arthroplasty for developmental dysplasia of the hip: A long-term evaluation
    Castagnini, Francesco
    Bordini, Barbara
    Cosentino, Monica
    Basile, Tommaso
    Giardina, Federico
    Traina, Francesco
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (07)
  • [2] Single-Taper Conical Tapered Stem in Total Hip Arthroplasty for Primary Osteoarthritis: A Comparative Long-Term Registry Evaluation
    Castagnini, Francesco
    Bordini, Barbara
    Cosentino, Monica
    Gorgone, Mara
    Minerba, Andrea
    Rotini, Marco
    Diquattro, Emanuele
    Traina, Francesco
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (19)
  • [3] Total hip arthroplasty with modular stem for Crowe I and II developmental dysplasia of the hip
    Xiangpeng Kong
    Yunming Sun
    Minzhi Yang
    Yonggang Zhou
    Jiying Chen
    Wei Chai
    Yan Wang
    Journal of Orthopaedic Surgery and Research, 14
  • [4] Subsidence of a Single-Taper Femoral Stem in Primary Total Hip Arthroplasty: Characterization, Associated Factors, and Sequelae
    Bornes, Troy D.
    Radomski, Lenny R.
    Bonello, John-Peter
    Mortensen-Truscott, Lukas
    Safir, Oleg A.
    Gross, Allan E.
    Kuzyk, Paul R. T.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07): : S174 - S178
  • [5] Role and results of tapered fluted modular titanium stems in revision total hip arthroplasty
    Munro, J. T.
    Garbuz, D. S.
    Masri, B. A.
    Duncan, C. P.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11): : 58 - 60
  • [6] Effect of a modular neck hip prosthesis on anteversion and hip rotation in total hip arthroplasty for developmental dysplasia of the hip
    Nakahara, Ema
    Uemura, Keisuke
    Ando, Wataru
    Hamada, Hidetoshi
    Takao, Masaki
    Sugano, Nobuhiko
    JOURNAL OF ARTIFICIAL ORGANS, 2020, 23 (03) : 255 - 261
  • [7] Effect of a modular neck hip prosthesis on anteversion and hip rotation in total hip arthroplasty for developmental dysplasia of the hip
    Ema Nakahara
    Keisuke Uemura
    Wataru Ando
    Hidetoshi Hamada
    Masaki Takao
    Nobuhiko Sugano
    Journal of Artificial Organs, 2020, 23 : 255 - 261
  • [8] Cementless Modular Total Hip Arthroplasty with Subtrochanteric Shortening Osteotomy for Hips with Developmental Dysplasia
    Takao, Masaki
    Ohzono, Kenji
    Nishii, Takashi
    Miki, Hidenobu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (06): : 548 - 555
  • [9] Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty
    Gustafson, J. A.
    Pourzal, R.
    Levine, B. R.
    Jacobs, J. J.
    Lundberg, H. J.
    BONE & JOINT JOURNAL, 2020, 102B (07): : 33 - 40
  • [10] Comparison of two tapered fluted modular titanium (TFMT) stems used in revision hip arthroplasty from a single center
    Pawar, Rajesh
    Yap, Rye
    Blow, Jody
    Garabadi, Mohanrao
    Rowsell, Mark
    Minhas, Hasnat
    Antapur, Prasad
    JOURNAL OF ORTHOPAEDICS, 2022, 34 : 196 - 200