Economic cost analysis of air-cooling process using different numbers of Peltier modules; Experimental case study

被引:6
|
作者
Shi, Lumin [1 ,2 ]
Abed, Azher M. [3 ]
Fayed, Mohamed [4 ]
Abdulghani, Zuhair R. [5 ]
Anqi, Ali E. [6 ]
Khadimallah, Mohamed Amine [7 ]
Moria, Hazim [5 ]
Wae-hayee, Makatar [8 ]
机构
[1] Lishui Univ, Business Sch, Lishui 323000, Zhejiang, Peoples R China
[2] Philippine Christian Univ, Manila 0900, Philippines
[3] Al Mustaqbal Univ Coll, Air Conditioning & Refrigerat Tech Engn Dept, Babylon 51001, Iraq
[4] Amer Univ Middle East, Coll Engn & Technol, Egaila, Kuwait
[5] Yanbu Ind Coll, Dept Mech Engn Technol, Yanbu Al Sinaiyah City 41912, Saudi Arabia
[6] King Khalid Univ, Coll Engn, Dept Mech Engn, Abha 61421, Saudi Arabia
[7] Prince Sattam Bin Abdulaziz Univ, Coll Engn Al Kharj, Dept Civil Engn, Al Kharj 11942, Saudi Arabia
[8] Prince Songkla Univ, Fac Engn, Dept Mech & Mechatron Engn, Hat Yai 90110, Songkhla, Thailand
关键词
Cost economic; SPECO; Thermoelectric; Peltier; Cooler; Air cooler; Experimental; THERMOELECTRIC COOLER; GENERATION; SYSTEM; TEMPERATURE; OPERATION; HYBRID;
D O I
10.1016/j.csite.2022.102627
中图分类号
O414.1 [热力学];
学科分类号
摘要
Generally speaking, a Peltier module obtains a high value of COP only for a small range of applied DC voltage. Indeed, increment of DC voltage sharply reduces its COP. Hence, to get a high total COP for a large-scale commercial Peltier air cooler (for example input power of 1000 W) each individual Peltier module should work with a small input DC voltage. This means, a greater number of Peltier modules should be employed in a real cooler to reduce the allocate DC voltage for any individual Peltier module. However, this means higher capital, maintenance, operating and maybe final cooling cost. Hence, a size related cost economic analysis is required for cooling process using Peltier module which is experimentally presented in this research. Three Peltier air coolers with different sizes (but in the same range of total input power) are investigated from efficiency and economic cost viewpoints. Findings show that despite the higher capital and maintenance cost for case "c" (6 TEM), it still provides cheaper cooling compared to the other cases. However, it is noted that case "b" (4 modules) provides 100% lower cooling cost compared to the case "a" (2 modules) while case "c" (6 modules) provides only 35% lower cooling cost compared to the case "b". This means, although increasing module number enhances the total COP of the cooler (for a given input power) and reduces the cooling cost, further increment of module number will finally augment the cooling cost of the cooler. Hence, an optimized number of modules can be selected for a large-scale cooling by simultaneous multi economic and cooling optimization. The quantitative and qualitative findings of this research can be useful for future marketing, and commercialization purposes of large-scale air-cooling process using Peltier module.
引用
收藏
页数:10
相关论文
共 38 条
  • [1] Numerical Analysis and Experimental Study on Temperature Field of Brake Disc during the Air-Cooling Process
    Zhang, Shizhen
    Wang, Weirui
    Jin, Liang
    Jiang, Wei
    MANUFACTURING PROCESS TECHNOLOGY, PTS 1-5, 2011, 189-193 : 2009 - 2012
  • [2] Forced convection air-cooling of a commercial electronic chassis: An experimental and computational case study
    Argento, CW
    Joshi, YK
    Osterman, MD
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART A, 1996, 19 (02): : 248 - 257
  • [3] Economic-effectiveness experimental case study for instant cooling of drinking-water using Peltier module
    Shi, Lumin
    Eldin, Sayed M.
    Abdulghani, Zuhair R.
    Ali, Elimam
    Guo, Wei
    Anqi, Ali E.
    Alkhamis, Nawaf
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 42
  • [4] Experimental comparative study on using different cooling techniques with photovoltaic modules
    Mohammed Alktranee
    Péter Bencs
    Journal of Thermal Analysis and Calorimetry, 2023, 148 : 3805 - 3817
  • [5] Experimental comparative study on using different cooling techniques with photovoltaic modules
    Alktranee, Mohammed
    Bencs, Peter
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (09) : 3805 - 3817
  • [6] A novel experimental case study on optimization of Peltier air cooler using Taguchi method
    Abdulghani, Zuhair R.
    RESULTS IN ENGINEERING, 2022, 16
  • [7] An experimental study of the enhancement of air-cooling limits for telecom/datacom heat sinks applications using an impinging air jet
    Sansoucy, E
    Oosthuizen, PH
    Refai-Ahmed, G
    ITHERM 2004, VOL 1, 2004, : 150 - 156
  • [8] Experimental study of air evaporative cooling process using microporous membranes
    Englart, Sebastian
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY SYSTEMS AND ENVIRONMENTAL ENGINEERING (ASEE17), 2017, 22
  • [9] Experimental study and analysis on hysteretic behavior of steel-concrete hybrid air-cooling structure with steel braces
    Du N.-J.
    Bai G.-L.
    Liu L.
    Zhao X.-G.
    Du, Ning-Jun (405737993@qq.com), 1600, Tsinghua University (34): : 205 - 215
  • [10] The economic value of green roofs: A case study using different cost-benefit analysis approaches
    Hekrle, Marek
    Liberalesso, Tiago
    Machac, Jan
    Silva, Cristina Matos
    JOURNAL OF CLEANER PRODUCTION, 2023, 413