Plasma Nitric Oxide Consumption Is Elevated and Associated With Adverse Outcomes in Critically Ill Patients

被引:4
|
作者
Dony, Christina A. [1 ]
Illipparambil, Lijo C. [1 ]
Maeda, Tetsuro [1 ]
Mroczek, Susan K. [1 ]
Rovitelli, Amy [1 ]
Wexler, Orren [1 ]
Malnoske, Michelle [2 ]
Bice, Tristan [1 ]
Fe, Alex Z. [1 ]
Storms, Casey R. [1 ]
Zhang, Jimmy [3 ]
Schultz, Rebecca D. [4 ]
Pietropaoli, Anthony P. [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Med, Div Pulm & Crit Care Med, Rochester, NY 14642 USA
[2] Arnot Hlth, Dept Med, Elmira, NY USA
[3] Mt Sinai Hosp, Div Pulm Crit Care & Sleep Med, New York, NY USA
[4] Univ Rochester, Med Ctr, Dept Resp Care, Div Pulm & Crit Care Med, Rochester, NY USA
基金
美国国家卫生研究院;
关键词
erythrocytes; hemoglobin; nitric oxide; septic shock; CELL-FREE HEMOGLOBIN; ORGAN FAILURE; SEPSIS; ARGININE; DIMETHYLARGININE; BIOAVAILABILITY; CERULOPLASMIN; REDUCTION; THERAPIES; MORTALITY;
D O I
10.1097/CCM.0000000000006006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
OBJECTIVES:Impaired nitric oxide (NO) bioavailability may contribute to microvascular dysfunction in sepsis. Excessive plasma NO consumption has been attributed to scavenging by circulating cell-free hemoglobin. This may be a mechanism for NO deficiency in sepsis and critical illness. We hypothesized that plasma NO consumption is high in critically ill patients, particularly those with sepsis, acute respiratory distress syndrome (ARDS), shock, and in hospital nonsurvivors. We further hypothesized that plasma NO consumption is correlated with plasma cell-free hemoglobin concentration.DESIGN:Retrospective cohort study.SETTING:Adult ICUs of an academic medical center.PATIENTS AND SUBJECTS:Three hundred sixty-two critically ill patients and 46 healthy control subjects.INTERVENTIONS:None.MEASUREMENTS AND MAIN RESULTS:Plasma NO consumption was measured using reductive chemiluminescence and cell-free hemoglobin was measured with a colorimetric assay. Mean (95% CI) plasma NO consumption (mu M) was higher in critically ill patients versus healthy control subjects (3.9 [3.7-4.1] vs 2.1 [1.8-2.5]), septic versus nonseptic patients (4.1 [3.8-4.3] vs 3.6 [3.3-3.8]), ARDS versus non-ARDS patients (4.4 [4.0-4.9] vs 3.7 [3.6-3.9]), shock vs nonshock patients (4.4 [4.0-4.8] vs 3.6 [3.4-3.8]), and hospital nonsurvivors versus survivors (5.3 [4.4-6.4] vs 3.7 [3.6-3.9]). These relationships remained significant in multivariable analyses. Plasma cell-free hemoglobin was weakly correlated with plasma NO consumption.CONCLUSIONS:Plasma NO consumption is elevated in critically ill patients and independently associated with sepsis, ARDS, shock, and hospital death. These data suggest that excessive intravascular NO scavenging characterizes sepsis and adverse outcomes of critical illness.
引用
收藏
页码:1706 / 1715
页数:10
相关论文
共 50 条
  • [1] Adverse Outcomes Associated With Fresh Frozen Plasma Transfusion In Critically Ill Patients
    Kaufman, M. A.
    Yin, S.
    Walley, K. R.
    Russell, J. A.
    Boyd, J. H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [2] Hypoxia-Inducible Factor-1: A Bridge Between Plasma Nitric Oxide and Adverse Outcomes in Critically Ill Patients
    Ruan, Hang
    Li, Shu-sheng
    Ran, Xiao
    CRITICAL CARE MEDICINE, 2024, 52 (04) : e211 - e212
  • [3] Nitric oxide production in critically ill patients
    Wong, HR
    Carcillo, JA
    Burckart, G
    Kaplan, SS
    ARCHIVES OF DISEASE IN CHILDHOOD, 1996, 74 (06) : 482 - 489
  • [4] Nitric oxide: Clinical applications in critically ill patients
    Redaelli, Simone
    Magliocca, Aurora
    Malhotra, Rajeev
    Ristagno, Giuseppe
    Citerio, Giuseppe
    Bellani, Giacomo
    Berra, Lorenzo
    Rezoagli, Emanuele
    NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 2022, 121 : 20 - 33
  • [5] POSTOPERATIVE HYPOTENSION IN THE CRITICALLY ILL IS ASSOCIATED WITH ADVERSE CLINICAL OUTCOMES
    Smischney, Nathan
    Shaw, Andrew
    Stapelfeldt, Wolf
    Boero, Isabel
    Chen, Qinyu
    Stevens, Mitali
    Khanna, Ashish
    CRITICAL CARE MEDICINE, 2020, 48
  • [6] Bacterial DNA plasma levels are elevated in the plasma of critically ill patients
    Lehmann, LE
    Klaschik, S
    Raadts, AD
    Schroeder, S
    von Spiegel, T
    Putensen, C
    Hoeft, A
    St Yber, F
    CRITICAL CARE MEDICINE, 2000, 28 (12) : A83 - A83
  • [7] TRANSFER OF CRITICALLY ILL PATIENTS WITH INHALED NITRIC-OXIDE
    GOLDMAN, AP
    TASKER, RC
    COOK, P
    MACRAE, DJ
    ARCHIVES OF DISEASE IN CHILDHOOD, 1995, 73 (05) : 480 - 480
  • [8] Decreased gastric nitric oxide in critically ill patients.
    Boivin, MA
    Fiack, C
    Harkins, M
    Iwamoto, GK
    JOURNAL OF INVESTIGATIVE MEDICINE, 2003, 51 : S128 - S129
  • [9] Indices of nitric oxide synthesis and outcome in critically ill patients
    Mackenzie, IM
    Garrard, CS
    Young, JD
    ANAESTHESIA, 2001, 56 (04) : 326 - 330
  • [10] ELEVATED LEVELS OF PLASMA HYPOXANTHINE AND XANTHINE IN CRITICALLY ILL PATIENTS
    GRUM, CM
    DANTZKER, DR
    FOX, IH
    SIMON, RH
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1983, 127 (04): : 99 - 99