Accurate Preoperative Evaluation of the Location of Esophagogastric Junction Adenocarcinoma Using Positron Emission Tomography-Computed Tomography

被引:0
|
作者
Wada, Noriko [1 ,2 ]
Kurokawa, Yukinori [1 ,4 ]
Takahashi, Tsuyoshi [1 ]
Saito, Takuro [1 ]
Yamamoto, Kazuyoshi [1 ]
Yamashita, Kotaro [1 ]
Tanaka, Koji [1 ]
Makino, Tomoki [1 ]
Nakajima, Kiyokazu [1 ]
Tatsumi, Mitsuaki [3 ]
Eguchi, Hidetoshi [1 ]
Doki, Yuichiro [1 ]
机构
[1] Osaka Univ, Dept Gastroenterol Surg, Grad Sch Med, Osaka, Japan
[2] Ikeda City Hosp, Dept Surg, Osaka, Japan
[3] Osaka Univ, Dept Radiol, Grad Sch Med, Osaka, Japan
[4] Osaka Univ, Dept Gastroenterol Surg, Grad Sch Med, 2-2 Yamadaoka, Suita, Osaka 5650871, Japan
关键词
esophagogastric junction; gastroesophageal junction; Siewert classification; SUV max; positron emission tomography; METABOLIC TUMOR VOLUME; FDG-PET; PREDICTION; CANCER; CHEMOTHERAPY; SURVIVAL; CHEMORADIOTHERAPY; ESOPHAGUS; CARCINOMA; DIAGNOSIS;
D O I
10.1177/00031348231183120
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The surgical procedure for esophagogastric junction (EGJ) adenocarcinoma usually depends on the location of its epicenter or proximal margin, but accurate evaluation of these positions is often difficult. The usefulness of positron emission tomography-computed tomography (PET-CT) for this purpose is unknown. Methods Between June 2005 and February 2015, we enrolled 30 patients with cT2-4 EGJ adenocarcinoma (Siewert type I/II) who underwent surgical resection. We ascertained the sensitivity and specificity of preoperative PET-CT for identifying the primary tumor and regional lymph node metastasis, and compared PET-CT and pathological findings in terms of the distance from the EGJ to the tumor epicenter or proximal tumor margin. Results PET-CT detected the primary tumor with a sensitivity of 97% (29/30), and detected lymph node metastasis with a sensitivity and specificity of 22% (4/18) and 100% (8/8), respectively. No significant association was observed between the maximal standardized uptake value and histological type, tumor size, or pT status. Regarding the accuracy of evaluating tumor location, the median differences between PET-CT and pathological measurements were .6 cm for the tumor epicenter and .5 cm for the proximal margin from the EGJ. PET-CT and pathological findings showed agreement regarding Siewert classification type (I or II) and lengths of esophageal involvement exceeding 4 cm or 2 cm in 77% (10/13), 85% (11/13), and 85% (11/13) of cases, respectively. Discussion PET-CT had high sensitivity for primary EGJ adenocarcinoma. It may effectively locate the tumor epicenter and proximal margin and thus help clinicians determine the optimal surgical procedure.
引用
收藏
页码:6005 / 6012
页数:8
相关论文
共 50 条
  • [1] Therapy Response Evaluation with Positron Emission Tomography-Computed Tomography
    Segall, George M.
    SEMINARS IN ULTRASOUND CT AND MRI, 2010, 31 (06) : 490 - 495
  • [2] Positron Emission Tomography-Computed Tomography in Liver Imaging
    Sharma, Bhuey
    Martin, Axel
    Zerizer, Lmene
    SEMINARS IN ULTRASOUND CT AND MRI, 2013, 34 (01) : 66 - 80
  • [3] Detection of Occult Melanoma by Preoperative Positron Emission Tomography-Computed Tomography and Intraoperative Ultrasonography
    Shoo, Brenda A.
    Kangelaris, Gerald
    Callen, Peter W.
    Kashani-Sabet, Mohammed
    Leong, Stanley P. L.
    JOURNAL OF CUTANEOUS MEDICINE AND SURGERY, 2010, 14 (03) : 130 - 135
  • [4] Role for positron emission tomography-computed tomography in melioidosis
    Ayub, Irfan Ismail
    Thangaswamy, Dhanasekar
    Krishna, Vidya
    Sridharan, Kopula Sathyamoorthy
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2021, 36 (03): : 354 - 356
  • [5] Prospective analysis of accuracy of positron emission tomography, computed tomography, and endoscopic ultrasonography in staging of adenocarcinoma of the esophagus and the esophagogastric junction
    Räsänen, JV
    Sihvo, EIT
    Knuuti, MJ
    Minn, HRI
    Luostarinen, MES
    Laippala, P
    Viljanen, T
    Salo, JA
    ANNALS OF SURGICAL ONCOLOGY, 2003, 10 (08) : 954 - 960
  • [6] Prospective Analysis of Accuracy of Positron Emission Tomography, Computed Tomography, and Endoscopic Ultrasonography in Staging of Adenocarcinoma of the Esophagus and the Esophagogastric Junction
    Jari V. Räsänen
    Eero I. T. Sihvo
    M. Juhani Knuuti
    Heikki R. I. Minn
    Markku E. S. Luostarinen
    Pekka Laippala
    Tapio Viljanen
    Jarmo A. Salo
    Annals of Surgical Oncology, 2003, 10 : 954 - 960
  • [7] Positron emission tomography-computed tomography on predicting the efficacy of targeted therapy for lung adenocarcinoma
    Rong, Xiaoxiang
    Cai, Xiaoli
    Li, Rong
    Chen, Jinzhang
    Wang, Quanshi
    You, Changxuan
    Wu, Wenyun
    Liu, Chuanxin
    Zhang, Junyi
    Luo, Rongcheng
    THORACIC CANCER, 2014, 5 (04) : 297 - 303
  • [8] Positron emission tomography-computed tomography evaluation for recurrent differentiated thyroid carcinoma
    Makeieff, M.
    Burcia, V.
    Raingeard, I.
    Eberle, M. C.
    Cartier, C.
    Garrel, R.
    Crampette, L.
    Guerrier, B.
    EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2012, 129 (05) : 251 - 256
  • [9] Positron Emission Tomography-Computed Tomography in the Evaluation of Fever of Unknown Origin: Correspondence
    Sookaromdee, Pathum
    Wiwanitkit, Viroj
    WORLD JOURNAL OF NUCLEAR MEDICINE, 2022, 21 (04) : 345 - 345
  • [10] Preoperative fluorodeoxyglucose positron emission tomography-computed tomography in papillary thyroid cancer: A futile exercise
    Garg, Pankaj Kumar
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2014, 42 (01) : 243 - 244