Oxygen therapy in intensive care

被引:1
|
作者
Gottlieb, Jens [1 ,2 ]
机构
[1] Hannover Med Sch, Klin Pneumol, Hannover, Germany
[2] Deutsch Zentrum Lungenforsch DZL, Biomed Res End Stage & Obstruct Lung Dis BREATH, Hannover, Germany
关键词
Sauerstofftherapie; High-Flow-Sauerstoff; Pulsoxymetrie; Hypoxamie; Hyperoxamie; oxygen inhalation therapy; hypoxia; respiratory rate; pulse oximetry; positive-pressure respiration; high-flow oxygen; PULSE OXIMETRY; MULTICENTER; MORTALITY; UNIT;
D O I
10.1055/a-1940-0553
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Was ist neu? Pulsoxymetrie und Blutgasanalysen Die Pulsoxymetrie hat eine hohe Sensitivitat, aber nur eine geringe Spezifitat zur Erfassung von Hypoxamien. Arterielle Blutgasanalysen sind der Goldstandard zur uberwachung einer O (2) -Therapie. Venose Blutgasanalysen sollten zur O (2) -Steuerung nicht zum Einsatz kommen. Zielwerte der O (2) -Therapie Der Zielbereich der akuten O (2) -Therapie fur beatmete Patienten und nicht beatmete Patienten ohne Hyperkapnie-Risiko soll bei einer pulsoxymetrisch gemessenen Sauerstoffsattigung (SpO (2) ) zwischen 92% und 96% liegen. Indikationen einer hochdosierten O (2) -Therapie ohne Zielbereich sind in der Intensivmedizin die Kohlenmonoxidvergiftung und Patienten mit schwerer Atemnot, wenn keine SpO (2) ableitbar ist. Eine Hyperoxamie, d.h. SpO (2) -Werte uber 96%, hat in randomisierten Studien an uberwiegend beatmeten Intensivpatienten das uberleben nicht verbessert. Unter einer Hyperoxamie bei nicht beatmeten Patienten mit Hyperkapnie-Risiko (z.B. Patienten mit chronisch-obstruktiver Lungenerkrankung) besteht bei jedem dritten Patienten das Risiko eines zunehmenden Kohlendioxidanstiegs. Deswegen soll bei diesen Patienten eine Ziel-SpO (2) von 88-92% angestrebt werden. O (2) -Zielbereiche an extrakorporalen Verfahren Es gibt keine randomisierten Studien, die andere SpO (2) -Zielbereiche fur Patienten an extrakorporalen Verfahren empfehlen. Diese Patienten sollen immer mit arteriellen Blutgasen - bei peripherer VA-ECMO am rechten Arm und hinter dem Oxygenator - uberwacht werden. High-Flow-Sauerstoff-Therapie beim akuten hyperkapnischen Atemversagen Die High-Flow-Sauerstoff-Therapie (HFNC) war in einer Metaanalyse uberwiegend bei Patienten mit akuter Hypoxamie (Typ-I-Atemversagen) gegenuber konventionellem O (2) nicht mit einer reduzierten Krankenhaussterblichkeit assoziiert, allerdings wurde die Intubationsrate reduziert. Auch beim moderaten hyperkapnischen Atemversagen (Typ II) ist die HFNC mit hohen Flussraten der nicht invasiven Beatmung (NIV) nicht unterlegen. Abstract Pulse oximetry and blood gas analyses Pulse oximetry has high sensitivity but low specificity for detecting hypoxemia. Arterial blood gas analyses are the gold standard for monitoring O2 therapy. Venous blood gas analyses should not be used in this setting. Target values of O2 therapy The target range of acute O2 therapy for ventilated patients and nonventilated patients not at risk of hypercapnia should be between 92% and 96% for oxygen saturation (SpO2) measured by pulse oximetry. Indications for high-dose O2 therapy without a target range in critical care include carbon monoxide poisoning and patients with severe respiratory distress when SpO2 cannot be derived. Hyperoxemia, i.e., SpO2 values above 96%, has not improved survival in randomized trials of predominantly ventilated ICU patients. Under hyperoxemia in nonventilated patients at risk of hypercapnia (e.g., patients with chronic obstructive pulmonary disease), one in three patients is at risk of increasing carbon dioxide. Therefore, a target SpO2 of 88-92% should be aimed for in these patients. O2 target ranges on extracorporeal procedures There are no randomized studies recommending other SpO2 target ranges for patients on extracorporeal procedures. These patients should always be monitored with arterial blood gases-in the case of peripheral VA-ECMO on the right arm and downstream of the oxygenator. High-flow oxygen therapy for acute hypercapnic respiratory failure High-flow oxygen therapy (HFNC) was not associated with reduced in-hospital mortality compared with conventional O2 in a meta-analysis of predominantly patients with acute hypoxemia (type I respiratory failure), although intubation rates were reduced. Also, in acute hypercapnic respiratory failure (type II), HFNC with high flow rates is not inferior to noninvasive ventilation (NIV).
引用
收藏
页码:759 / 766
页数:8
相关论文
共 50 条
  • [1] Oxygen Therapy in Emergency and Intensive Care Medicine
    Grensemann, Joern
    Wachs, Christian
    Kluge, Stefan
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2021, 146 (02) : 108 - 120
  • [2] High flow oxygen therapy in intensive care and anaesthesiology
    Maciejewski, Dariusz
    ANAESTHESIOLOGY INTENSIVE THERAPY, 2019, 51 (01) : 41 - 50
  • [3] The controversies surrounding oxygen therapy in neonatal intensive care units
    Sinha, SK
    Tin, W
    CURRENT OPINION IN PEDIATRICS, 2003, 15 (02) : 161 - 165
  • [4] INTENSIVE CARE - INTENSIVE THERAPY
    不详
    BRITISH JOURNAL OF ANAESTHESIA, 1968, 40 (01) : 1 - &
  • [5] Attitudes of Dutch intensive care unit clinicians towards oxygen therapy
    Grim, C. C. A.
    Cornet, A. D.
    Kroner, A.
    Meinders, A-J.
    Brouwers, A. J. B. W.
    Reidinga, A. C.
    van Westerloo, D. J.
    Bergmans, D. C. J. J.
    Gommers, D.
    Versluis, D.
    Weller, D.
    Boerma, E. Christiaan
    van Driel, E.
    de Jonge, E.
    Schoonderbeek, F. J.
    Helmerhorst, H. J. F.
    Jongsma-van Netten, H. G.
    Weenink, J.
    Woittiez, K. J.
    Simons, K. S.
    van Welie, L.
    Petjak, M.
    Sigtermans, M. J.
    van der Woude, M.
    Cremer, O. L.
    Bijlstra, P.
    van der Heiden, P.
    So, R. K. L.
    Vink, R.
    Jansen, T.
    de Ruijter, W.
    NETHERLANDS JOURNAL OF MEDICINE, 2020, 78 (04): : 167 - 174
  • [6] High-flow nasal oxygen therapy in intensive care and anaesthesia
    Renda, T.
    Corrado, A.
    Iskandar, G.
    Pelaia, G.
    Abdalla, K.
    Navalesi, P.
    BRITISH JOURNAL OF ANAESTHESIA, 2018, 120 (01) : 18 - 27
  • [7] Low-flow oxygen therapy in intensive care: An observational study
    Eastwood, Glenn M.
    O'Connell, Bev
    Considine, Julie
    AUSTRALIAN CRITICAL CARE, 2011, 24 (04) : 269 - 278
  • [8] HOME OXYGEN-THERAPY FOLLOWING NEONATAL INTENSIVE-CARE
    GREENOUGH, A
    HIRD, MF
    GAMSU, HR
    EARLY HUMAN DEVELOPMENT, 1991, 26 (01) : 29 - 35
  • [9] Ventilation and oxygen therapy Intensive care studies from 2018-2019
    Dietrich, M.
    Reuss, C. J.
    Beynon, C.
    Hecker, A.
    Jungk, C.
    Michalski, D.
    Nusshag, C.
    Schmidt, K.
    Bernhard, M.
    Brenner, T.
    Weigand, M. A.
    ANAESTHESIST, 2019, 68 (11): : 770 - 776
  • [10] HOME OXYGEN THERAPY UTILIZATION IN A NEWBORN INTENSIVE CARE UNIT POPULATION AT ELEVATION
    Rodriguez, D.
    Aragon, A.
    Gross, J.
    Reddish, J.
    Maxwell, J. R.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2025, 73 (01) : 200 - 200