Experimental and numerical investigation of transient starting of pre-evacuated exhaust diffuser in high altitude ground test

被引:6
|
作者
Afkhami, Sina [1 ]
Fouladi, Nematollah [2 ]
Fard, Mahmoud Pasandideh [1 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Aerosp Engn, Mashhad, Iran
[2] Space Transportat Res Inst, Tehran, Iran
关键词
High altitude test facility; Second throat exhaust diffuser; Pre-evacuation; Thrust optimized parabolic nozzle; Transient starting; PERFORMANCE;
D O I
10.1016/j.ast.2023.108111
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
This paper deals with numerical and experimental investigation of exhaust diffuser transient starting in a high-altitude ground test of a thrust optimized parabolic (TOP) nozzle. The experimental investigation has focused on cold gas flow inside TOP nozzle and second throat exhaust diffuser (STED), performed to examine flow unsteadiness at the starting phase. In order to identify physical phenomena during STED starting, unsteady numerical simulations have also been carried out. Two major parameters including nozzle pressure slope and pre-evacuated regions along the diffuser have been examined. The results indicate elimination of the cap shock separation or restricted shock separation (RSS) pattern during the transient starting at high nozzle pressure slope with pre-evacuation. Also, considerable reduction in the starting time is achieved, so that it causes more desirable instantaneous starting of the diffuser in some conditions. However, at average and lower nozzle pressure slopes, RSS pattern still develops inside the nozzle. Investigation of the effect of pre-evacuation spaces along the diffuser on the course of evacuation development indicates that the larger the pre-evacuation space along the diffuser, the more desirable is the STED operation quality, whereby the starting time decreases considerably. It is shown that with a given nozzle pressure slop, enlarging the pre-evacuation area from the diffuser inlet to the middle of the second throat results in a 25% reduction in diffuser starting time, and the further increase of the pre-evacuation area to the end section of the diffuser leads to instantaneous starting of the diffuser. Furthermore, we found that initial pre-evacuation pressure value has less effect on the diffuser starting process, so that for a given nozzle pressure slop and a pre-evacuation area by reducing this parameter five times, the starting time is reduced by only 3.75%.(c) 2023 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:16
相关论文
共 32 条
  • [1] Starting transient analysis of second throat exhaust diffuser in high-altitude test of a thrust optimized parabolic nozzle
    Fouladi, Nematollah
    Afkhami, Sina
    Pasandideh Fard, Mahmoud
    PHYSICS OF FLUIDS, 2023, 35 (06)
  • [2] Studies on the starting transient of a straight cylindrical supersonic exhaust diffuser: Effects of diffuser length and pre-evacuation state
    Park, Byung Hoon
    Lee, Ji Hyung
    Yoon, Woongsup
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2008, 29 (05) : 1369 - 1379
  • [3] STEAM TURBINE AXIAL EXHAUST DIFFUSER INVESTIGATION USING A TEST RIG AND ITS NUMERICAL MODEL
    Kalista, Robert
    Mrozek, Lukas
    Slama, Vaclav
    Sedlak, Kamil
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 6, 2019,
  • [4] Flow dynamics at the minimum starting condition of a supersonic diffuser to simulate a rocket's high altitude performance on the ground
    Yeom, Hyo-Won
    Yoon, Sangkyu
    Sung, Hong-Gye
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2009, 23 (01) : 254 - 261
  • [5] Flow dynamics at the minimum starting condition of a supersonic diffuser to simulate a rocket’s high altitude performance on the ground
    Hyo-Won Yeom
    Sangkyu Yoon
    Hong-Gye Sung
    Journal of Mechanical Science and Technology, 2009, 23 : 254 - 261
  • [6] Numerical and experimental investigation on the diffuser optimization of a reactor coolant pump with orthogonal test approach
    Long Yun
    Zhu Rongsheng
    Wang Dezhong
    Yin Junlian
    Li Tianbin
    Journal of Mechanical Science and Technology, 2016, 30 : 4941 - 4948
  • [7] Numerical and experimental investigation on the diffuser optimization of a reactor coolant pump with orthogonal test approach
    Long Yun
    Zhu Rongsheng
    Wang Dezhong
    Yin Junlian
    Li Tianbin
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (11) : 4941 - 4948
  • [8] Experimental and numerical investigation on steady and transient flow in the flat-walled micro-diffuser/nozzle
    He, Xiuhua
    Lin, Nan
    Xu, Wei
    Uzoejinwa, B. B.
    Deng, Zhidang
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2018, 24 (04): : 1853 - 1861
  • [9] Experimental and numerical investigation on steady and transient flow in the flat-walled micro-diffuser/nozzle
    Xiuhua He
    Nan Lin
    Wei Xu
    B. B. Uzoejinwa
    Zhidang Deng
    Microsystem Technologies, 2018, 24 : 1853 - 1861
  • [10] Ground Test Investigation of Temperature Distribution in Four Parallel High-Altitude Engines
    Qin, Wenbo
    Cheng, Huier
    Li, Peng
    JOURNAL OF PROPULSION AND POWER, 2009, 25 (03) : 753 - 759