Comparison of a high-definition three-dimensional digital camera system with a conventional state-of-the-art operation microscope for microsurgical anastomoses

被引:1
|
作者
Fichter, Andreas M. [1 ]
Wolff, Constantin T. [1 ]
Grabenhorst, Alex [1 ]
Koss, Leonard H. [1 ,2 ]
von Bomhard, Achim [1 ]
Nieberler, Markus [1 ]
Wolff, Klaus-Dietrich [1 ]
Ritschl, Lucas M. [1 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Oral & Maxillofacial Surg, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[2] Univ Cologne, Dept Oral & Maxillofacial Surg, Kerpener Str 62, D-50937 Cologne, Germany
关键词
D O I
10.1038/s41598-023-37530-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Since its clinical implementation, microvascular surgery has depended on the continuous improvement of magnification tools. One of the more recent developments is a high-definition three-dimensional (3D) digital system (exoscope), which provides an alternative to the state-of-the-art operating microscopes. This study aimed to evaluate the advantages and disadvantages of this technology and compare it with its predecessor. The study included 14 surgeons with varying levels of experience, none of which had used a 3D optical system previously. Six of these surgeons performed five arterial and five venous anastomoses in the chicken thigh model with both the VITOM 3D exoscope-guided system and the Pentero operating microscope. These anastomoses were then evaluated for their quality and anastomosis time. The participants and the other eight surgeons, who had used the digital 3D camera system for microsurgical training exercises and vascular sutures, answered a questionnaire. The anastomosis time and number of complications were lower with the conventional microscope. Participants rated the image quality with the conventional microscope as higher, whereas the field of view and ergonomics were favorable in the digital 3D camera system. Exoscopes are optics suitable for performing simple microvascular procedures and are superior to classical microscopes ergonomically. Thus far, they are inferior to classical microscopes in terms of image quality and 3D imaging.
引用
收藏
页数:10
相关论文
共 25 条
  • [1] Comparison of a high-definition three-dimensional digital camera system with a conventional state-of-the-art operation microscope for microsurgical anastomoses
    Andreas M. Fichter
    Constantin T. Wolff
    Alex Grabenhorst
    Leonard H. Koss
    Achim von Bomhard
    Markus Nieberler
    Klaus-Dietrich Wolff
    Lucas M. Ritschl
    Scientific Reports, 13
  • [2] Design and calibration of a new high-definition three-dimensional laparoscopic system
    Tang, Jia
    Wang, Li-qiang
    Yuan, Bo
    Jiang, Hong
    Zhu, Qi-ming
    FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2015, 16 (01) : 79 - 84
  • [3] Comparison of two-dimensional high-definition, ultra high-definition and three-dimensional endovision systems: an ex-vivo randomised study
    Bhattacharjee, Hemanga K.
    Chaliyadan, Shafneed
    Mishra, Ashwani K.
    Agarwal, Harshit
    Suhani, Suhani
    Joshi, Mohit
    Parshad, Rajinder
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (09): : 5328 - 5337
  • [4] Comparison of two-dimensional high-definition, ultra high-definition and three-dimensional endovision systems: an ex-vivo randomised study
    Hemanga K. Bhattacharjee
    Shafneed Chaliyadan
    Ashwani K. Mishra
    Harshit Agarwal
    Suhani Suhani
    Mohit Joshi
    Rajinder Parshad
    Surgical Endoscopy, 2021, 35 : 5328 - 5337
  • [5] Three-Dimensional Printing and Digital Flow in Human Medicine: A Review and State-of-the-Art
    Salazar-Gamarra, Rodrigo
    Contreras-Pulache, Hans
    Cruz-Gonzales, Gloria
    Binasco, Salvatore
    Cruz-Gonzales, William
    Moya-Salazar, Jeel
    APPLIED SYSTEM INNOVATION, 2022, 5 (06)
  • [6] New technique: Design and calibration of a new high-definition three-dimensional laparoscopic system
    Tang, Jia
    Wang, Li-qiang
    Yuan, Bo
    Jiang, Hong
    Zhu, Qi-ming
    Frontiers of Information Technology and Electronic Engineering, 2015, 16 (01): : 79 - 84
  • [7] Cadaveric hands-on workshop using a three-dimensional high-definition television system
    Okudera, H
    Goel, A
    Kyoshima, K
    Kobayashi, S
    SKULL BASE SURGERY, 1996, 6 (03): : 191 - 192
  • [8] New technique: Design and calibration of a new high-definition three-dimensional laparoscopic system
    Jia Tang
    Li-qiang Wang
    Bo Yuan
    Hong Jiang
    Qi-ming Zhu
    Frontiers of Information Technology & Electronic Engineering, 2015, 16 (1) : 79 - 84
  • [9] Full high-definition real-time depth estimation for three-dimensional video system
    Li, Hejian
    An, Ping
    Zhang, Zhaoyang
    OPTICAL ENGINEERING, 2014, 53 (09)
  • [10] Three-Dimensional Vascular Indices Calculated Using Conventional Power Doppler and High-Definition Flow Imaging Are There Differences?
    Luis Alcazar, Juan
    Kudla, Marek J.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (05) : 761 - 766