Evaluation of partial pressure CO2 change in the dialyzer blood inlet during hemodialysis as a measure of vascular access recirculation

被引:0
|
作者
Rotondi, Silverio [1 ,2 ]
Perrotta, Adolfo [2 ]
Pintus, Giovanni [1 ]
Capasso, Laura [2 ]
Pasquali, Marzia [3 ]
Farcomeni, Alessio [4 ]
Paoloni, Emanuela [2 ]
Mazzaferro, Sandro [1 ,2 ,3 ]
Tartaglione, Lida [3 ]
机构
[1] Sapienza Univ Rome, Dept Translat & Precis Med, Rome, Italy
[2] Polo Pontino Sapienza Univ Rome, ICOT Hosp, Nephrol & Dialysis Unit, Rome, Italy
[3] Univ Policlin Umberto I Hosp, Dept Internal Med & Med Special, Nephrol Unit, Rome, Italy
[4] Univ Roma Tor Vergata, Dept Econ & Finance, Rome, Italy
关键词
hemodialysis; pCO(2); recirCO2lation test; vascular access recirculation; CLINICAL-PRACTICE GUIDELINE;
D O I
10.1111/hdi.13109
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Vascular access recirculation during hemodialysis is associated with reduced effectiveness and worse survival outcomes. To evaluate recirculation, an increase in pCO(2) in the blood of the arterial line during hemodialysis (threshold of 4.5 mmHg) was proposed. The blood returning from the dialyzer in the venous line has significantly higher pCO2, so in the presence of recirculation, pCO2 in the arterial blood line may increase (Delta pCO(2)) during hemodialysis sessions. The aim of our study was to evaluate Delta pCO(2) as a diagnostic tool for vascular access recirculation in chronic hemodialysis patients. Methods: We evaluated vascular access recirculation with Delta pCO(2) and compared it with the results of a urea recirculation test, which is the gold standard. Delta pCO(2) was obtained from the difference in pCO(2) in the arterial line at baseline (pCO(2)T1) and after 5 min of hemodialysis (pCO(2)T.2). Delta pCO(2) = pCO(2)T2-pCO(2)T1. Findings: In 70 hemodialysis patients (mean age: 70.52 +/- 13.97 years; hemodialysis vintage of 41.36 +/- 34.54, KT/V 1.4 +/- 0.3), Delta pCO(2) was 4 +/- 4 mmHg, and urea recirculation was 7% +/- 9%. Vascular access recirculation was identified using both methods in 17 of 70 patients, who showed a Delta pCO(2) of 10 +/- 5 mmHg and urea recirculation of 20% +/- 9%; time in months of hemodialysis was the only difference between vascular access recirculation and non-vascular access recirculation patients (22 +/- 19 vs. 46 +/- 36, p: 0.05). In the non-vascular access recirculation group, the average Delta pCO(2) was 1.9 +/- 2 (p: 0.001), and the urea recirculation % was 2.8 +/- 3 (p: 0.001). The Delta pCO(2) correlated with the urea recirculation % (R: 0.728; p < 0.001). Discussion: Delta pCO(2) in the arterial blood line during hemodialysis is an effective and reliable diagnostic tool for identifying recirculation of the vascular access but not its magnitude. The Delta pCO(2) test application is simple and economical and does not require special equipment.
引用
收藏
页码:370 / 377
页数:8
相关论文
共 50 条
  • [1] HYPOVENTILATION AND HYPOXEMIA DURING HEMODIALYSIS - REFLEX RESPONSE TO REMOVAL OF CO2 ACROSS DIALYZER
    SHERLOCK, J
    LEDWITH, J
    LETTERI, J
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1977, 23 : 406 - 410
  • [2] CO2 QUINHYDRONE ELECTRODE, A NEW METHOD TO MEASURE PARTIAL CO2 PRESSURE IN GASES AND LIQUIDS
    VANKEMPE.LH
    DEURENBE.HP
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1971, 324 (01): : 80 - &
  • [3] VOLUNTARY HYPERVENTILATION AND PARTIAL CO2 PRESSURE IN ARTERIAL BLOOD
    VIOLA, AR
    ABBATE, EH
    DELRIO, P
    MARCHISSIO, ML
    MEDICINA-BUENOS AIRES, 1976, 36 (06) : 555 - 555
  • [4] Two-operator glucose infusion test (GIT2) for vascular access recirculation measurement during hemodialysis
    Bosticardo, Gian Mario
    Morellini, Veronica
    Schillaci, Enrico
    Battisti, Marco
    Norza, Massimo
    Detoma, Paolo
    Forneris, Giacomo
    Filiberti, Oliviero
    Bajardi, Pietro
    JOURNAL OF VASCULAR ACCESS, 2010, 11 (01): : 38 - 40
  • [5] CO2-QUINHYDRONE ELECTRODE - NEW METHOD TO MEASURE PARTIAL CO2 PRESSURE IN GASES AND LIQUIDS
    VANKEMPEN, LH
    DEURENBERG, H
    KREUZER, F
    RESPIRATION PHYSIOLOGY, 1972, 14 (03): : 366 - +
  • [6] BLOOD OSMOLALITY DURING INVIVO CHANGES OF CO2 PRESSURE
    BONING, D
    VAAS, U
    BRAUMANN, KM
    JOURNAL OF APPLIED PHYSIOLOGY, 1983, 54 (01) : 123 - 129
  • [7] OBSERVATIONS ON PARTIAL-PRESSURE OF CO2 IN CAROTID ARTERIAL BLOOD IN CATS
    CARRUTHERS, B
    PONTE, J
    PURVES, MJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1978, 284 (NOV): : P166 - P167
  • [8] Cerebral blood flow as measured by MRI during changes in end-tidal CO2 partial pressure
    Cara, DM
    Girling, KJ
    Morgan, PS
    Moody, AR
    Mahajan, RP
    BRITISH JOURNAL OF ANAESTHESIA, 2001, 86 (02) : 306P - 306P
  • [9] Evaluation of CO2 solubility in potential aqueous amine-based solvents at low CO2 partial pressure
    Singh, Prachi
    Brilman, D. W. F.
    Groeneveld, Michiel J.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (01) : 61 - 68
  • [10] SEROUS EFFUSIONS OF TUBERCULOSIS IN ANIMAL AND MAN - MEASURE OFPH, O2 AND CO2 PARTIAL PRESSURE
    MOLINE, J
    HAMELINP.A
    COMPTES RENDUS DES SEANCES DE LA SOCIETE DE BIOLOGIE ET DE SES FILIALES, 1970, 164 (07): : 1616 - &