Development and Calibration of an Indigenous Spectroscopic System for Radiation Portal Monitor Application

被引:0
|
作者
Fnu, Akanchha [1 ]
Bhadouria, Vikesh Singh [1 ]
Pandey, Arun Kumar [1 ]
Wahi, Pankaj [2 ]
Sinha, Niraj [2 ]
Munshi, Prabhat [1 ]
机构
[1] Indian Inst Technol Kanpur, Nucl Engn & Technol Programme, Kanpur 208016, Uttar Pradesh, India
[2] Indian Inst Technol Kanpur, Dept Mech Engn, Kanpur 208016, Uttar Pradesh, India
关键词
special nuclear materials; radiation portal monitors; gamma radiation; nuclear security; SCINTILLATORS;
D O I
10.1115/1.4056464
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The growing terrorism threat based on the use of special nuclear materials (SNMs), which includes highly enriched uranium (HEU), weapons-grade plutonium (WGPu), or high-activity radiological sources has reinforced the need for improved population protection mechanisms. The motivation for the development of a radiation portal monitor is the need for inspecting cargo at various entry points of the country. This inspection process requires scanning many containers for the presence of SNMs such as Uranium, Thorium, and Plutonium. In this study, we have worked on designing a system with eight NaI (Tl) detectors for the detection of any gamma-emitting radioactive source. The multichannel analyzer for collecting the data from the detectors has also been indigenously developed using PXIe-6386 data acquisition system with a sampling rate of 14 MS/s. The system is automated using labview platform. The system is capable of detection as well as identification of the SNMs passing through it in static conditions. The energy spectra of various radionuclides, such as Cs-137, Co-60, and Mn-54, measured using our RPM have been used for the validation of the identification of sources with unknown energy lines.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Spectroscopic radiation portal monitor prototype
    McCormick, Kathleen
    Stromswold, David
    Ely, James
    Schweppe, John
    Kouzes, Richard
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 292 - 296
  • [2] Radiation Portal Monitor calibration 2 and startup.
    Hoyt, JR
    Shipler, DB
    Ames, KR
    Sitsler, RB
    Jones, RA
    Antonio, EJ
    HEALTH PHYSICS, 2005, 89 (01): : S64 - S64
  • [3] Testing and performances of Spectroscopic Radiation Portal Monitor for homeland security
    Deyglun, C.
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2019), 2020, 225
  • [4] Performance Evaluation of an Imaging Radiation Portal Monitor System
    Vasiljevic, Jana
    Cederwall, Bo
    APPLIED SCIENCES-BASEL, 2022, 12 (18):
  • [5] Analysis of spectroscopic radiation portal monitor data using principal components analysis
    Runkle, Robert C.
    Tardiff, Mark F.
    Anderson, Kevin K.
    Carlson, Deborah K.
    Smith, L. Eric
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1418 - 1423
  • [6] DEVELOPMENT AND CALIBRATION OF A NEW, LOW COST RADIATION MONITOR FOR HIGH RADIATION ORBITS
    Bamber, D.
    Ryden, K.
    Tye, D.
    Underwood, C.
    2018 18TH EUROPEAN CONFERENCE ON RADIATION AND ITS EFFECTS ON COMPONENTS AND SYSTEMS (RADECS), 2018, : 263 - 267
  • [7] Strip detectors for a portal monitor application
    Russo, G. V.
    Lo Presti, D.
    Bonanno, D.
    Indelicato, V.
    La Rocca, P.
    Leonora, E.
    Longhitano, F.
    Pugliatti, C.
    Randazzo, N.
    Riggi, F.
    Santagati, G.
    Zappala, G.
    Blancato, A. A.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [8] Standardisation of radiation portal monitor controls and readouts
    Tinker, M.
    RADIATION PROTECTION DOSIMETRY, 2010, 141 (03) : 305 - 308
  • [9] Development and application of automated vicarious calibration system
    韦玮
    宋帅
    孙彦港
    邱刚刚
    李新
    郑小兵
    Chinese Optics Letters, 2017, 15 (10) : 5 - 10
  • [10] Development and application of automated vicarious calibration system
    Wei, Wei
    Song, Shuai
    Sun, Yangang
    Qiu, Ganggang
    Li, Xin
    Zheng, Xiaobing
    CHINESE OPTICS LETTERS, 2017, 15 (10)