Finite element analysis and clinical application of 3D-printed Ti alloy implant for the reconstruction of mandibular defects

被引:6
|
作者
Xue, Runqi [1 ]
Lai, Qingguo [1 ]
Xing, Hongyu [3 ]
Zhong, Chiyang [1 ]
Zhao, Yixuan [2 ]
Zhu, Kaiwen [2 ]
Deng, Yanwei [1 ]
Liu, Chengbin [4 ]
机构
[1] Shandong Univ, Dept Oral & Maxillofacial Surg, Hosp 2, Jinan 250033, Shandong Provin, Peoples R China
[2] Shandong Univ, Jinan, Shandong Provin, Peoples R China
[3] Shandong Jinan Univ, Sch Mech & Elect Engn, Jinan, Shandong Provin, Peoples R China
[4] Zaozhuang Municipal Hosp, Zaozhuang, Shandong Provin, Peoples R China
关键词
3D printing; Maxillofacial surgery; Reconstruction; Finite element analysis; Biomechanics; Personalized medicine; PLATES; FRACTURE; BONE;
D O I
10.1186/s12903-024-03857-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe reconstruction of segmental defect of the mandible has always been a challenge. The customized reconstruction plate without a bone graft is also considered a transitional means of rehabilitation and reconstruction in some cases.MethodsThis study evaluated the biomechanical behaviors of customized plates with different structural designs comparing with commercial plates using the finite element method in reconstrution of the lateral mandible defect.ResultsSimulations revealed the stress state in the plate bodies, bone tissues and screws were associated with the width, height, thickness of the plates as well as the distribution of screws. In all of the groups, the system of 16 mm-high, 2.8 mm-thick customized reconstruction plate with 10 screws was considered to be the most ideal design because of the most harmonious biomechanical state. What's more, the stress shielding effects were not obvious in this experiment. Based on the above findings, we conducted a clinical case analysis to verify the mechanical properties of customized reconstruction and obtained a satisfactory operation result.ConclusionsThe results show that by adjusting the contour parameters of the reconstruction plates, an ideal and reliable customized plate can be manufactured. And the customized 3D-printed Ti alloy implant will be a new way to achieve mandibular reconstruction in patients unable to perform autologous bone graft surgery.Trial registrationThe present trial has been registered with ChiCTR, the registration number is ChiCTR 2,000,038,973 on 11/10/2020.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Finite element analysis and clinical application of 3D-printed Ti alloy implant for the reconstruction of mandibular defects
    Runqi Xue
    Qingguo Lai
    Hongyu Xing
    Chiyang Zhong
    Yixuan Zhao
    Kaiwen Zhu
    Yanwei Deng
    Chengbin Liu
    BMC Oral Health, 24
  • [2] Clinical application of 3D-printed PEEK implants for repairing mandibular defects
    Li, Yunpeng
    Li, Zhiye
    Tian, Lei
    Li, Dichen
    Lu, Bin
    Shi, Changquan
    Niu, Qiang
    Liu, Fuwei
    Kong, Liang
    Zhang, Junrui
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2022, 50 (08) : 621 - 626
  • [3] Secondary Mandibular Reconstruction with Patient-Specific 3D-Printed Implant
    Sharma, Neha
    Singh, Harsimran
    Goyal, Anish
    Malhotra, Mandeep Singh
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2024, 23 (02): : 258 - 260
  • [4] Secondary Mandibular Reconstruction with Patient-Specific 3D-Printed Implant
    Neha Sharma
    Harsimran Singh
    Anish Goyal
    Mandeep Singh Malhotra
    Journal of Maxillofacial and Oral Surgery, 2024, 23 : 258 - 260
  • [5] Finite element analysis of 3D-printed personalized titanium plates for mandibular angle fracture
    Li, Yan
    Li, Hui
    Lai, Qingguo
    Xue, Runqi
    Zhu, Kaiwen
    Deng, Yanwei
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (01) : 78 - 89
  • [6] 3D-printed PEEK implant for mandibular defects repair-a new method
    Kang, Jianfeng
    Zhang, Jie
    Zheng, Jibao
    Wang, Ling
    Li, Dichen
    Liu, Shuguang
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 116
  • [7] Assembly of 3D-printed Ti scaffold and free vascularized fibula using a customized Ti plate for the reconstruction of mandibular defects
    Zhong, Chiyang
    Zhao, Yixuan
    Xing, Hongyu
    Lai, Qingguo
    Xue, Runqi
    Song, Tianxiang
    Tang, Xiaopeng
    Zhu, Kaiwen
    Deng, Yanwei
    BIO-DESIGN AND MANUFACTURING, 2022, 5 (02) : 424 - 429
  • [8] Assembly of 3D-printed Ti scaffold and free vascularized fibula using a customized Ti plate for the reconstruction of mandibular defects
    Chiyang Zhong
    Yixuan Zhao
    Hongyu Xing
    Qingguo Lai
    Runqi Xue
    Tianxiang Song
    Xiaopeng Tang
    Kaiwen Zhu
    Yanwei Deng
    Bio-Design and Manufacturing , 2022, (02) : 424 - 429
  • [9] Assembly of 3D-printed Ti scaffold and free vascularized fibula using a customized Ti plate for the reconstruction of mandibular defects
    Chiyang Zhong
    Yixuan Zhao
    Hongyu Xing
    Qingguo Lai
    Runqi Xue
    Tianxiang Song
    Xiaopeng Tang
    Kaiwen Zhu
    Yanwei Deng
    Bio-Design and Manufacturing, 2022, 5 (02) : 424 - 429
  • [10] Assembly of 3D-printed Ti scaffold and free vascularized fibula using a customized Ti plate for the reconstruction of mandibular defects
    Chiyang Zhong
    Yixuan Zhao
    Hongyu Xing
    Qingguo Lai
    Runqi Xue
    Tianxiang Song
    Xiaopeng Tang
    Kaiwen Zhu
    Yanwei Deng
    Bio-Design and Manufacturing, 2022, 5 : 424 - 429