Biofeedback Training after Successful Inverted Internal Limiting Membrane (ILM)-Flap Technique for High Myopic Macular Hole

被引:0
|
作者
Sborgia, Alessandra [1 ]
Niro, Alfredo [2 ]
Pastore, Valentina [1 ]
Albano, Valeria [1 ]
Boscia, Giacomo [1 ]
Piepoli, Marina [1 ]
Di Pardo, Camilla [1 ]
Tagano, Lorenzo Accurso [1 ]
Zerbinati, Marta [1 ]
Landini, Luca [1 ]
Pignataro, Maria Grazia [1 ]
Petruzzella, Giovanni [1 ]
Donghia, Rossella [3 ]
Alqahtani, Abdullah S. [4 ,5 ,6 ]
Coassin, Marco [7 ]
Dell'Omo, Roberto [8 ]
Boscia, Francesco [1 ]
Alessio, Giovanni [1 ]
Sborgia, Giancarlo [1 ]
机构
[1] Univ Bari, Dept Med Sci Neurosci & Sense Organs, Eye Clin, I-70124 Bari, Italy
[2] ASL Taranto, SS Annunziata Hosp, Eye Clin, I-74100 Taranto, Italy
[3] Natl Inst Gastroenterol S de Bellis Res Hosp, I-70013 Castellana Grotte, Italy
[4] Natl Guard Hosp, Dept Surg, Div Ophthalmol, Riyadh 31982, Saudi Arabia
[5] King Saud Bin Abdulaziz Univ Hlth Sci, Jeddah 22384, Saudi Arabia
[6] King Abdullah Int Med Res Ctr, Jeddah 22384, Saudi Arabia
[7] Univ Campus Biomed, Ophthalmol, I-00128 Rome, Italy
[8] Univ Molise, Dept Med & Hlth Sci Vincenzo Tiberio, I-86100 Campobasso, Italy
关键词
high myopic macular hole; inverted flap technique; microperimeter; biofeedback; retinal sensitivity; fixation; PREFERRED RETINAL LOCUS; FIXATION STABILITY; FLAP TECHNIQUE; COHERENCE TOMOGRAPHY; ECCENTRIC FIXATION; MP-1; DEGENERATION; SENSITIVITY; DETACHMENT; LOCATION;
D O I
10.3390/jcm12165188
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Microperimetric biofeedback training improved visual acuity and fixation stability in patients who previously underwent macular surgery. We aimed to compare the functional results of biofeedback training with the standard of care in patients who underwent successful inverted Internal Limiting Membrane (ILM)-flap technique for high myopic macular holes (hMMH). Methods: This was a retrospective, comparative, cohort study. Patients with hMMH after surgical hole closure underwent microperimetric biofeedback using structured light stimulus plus acoustic tone (n = 12; Biofeedback) or standard of care with scheduled visits (n = 11; Control). Best-corrected visual acuity, retinal sensitivity at central 12(circle) (RS) and 4(circle) (CRS) with a mean deviation at central 12(circle) (MD), and fixation stability as bivariate contour ellipse area (BCEA 68%, 95%, and 99%) were assessed at baseline and month 1, 3, 6, and 12. The Mann-Whitney test was used to test the difference between the groups. Results: Baseline functional parameters were not significantly different among the groups. BCVA significantly improved in each group (Biofeedback, p = 0.002; Control, p <= 0.02) at all follow-up visits. CRS significantly improved at 6 (p = 0.03) and 12 (p = 0.01) months in the Biofeedback group and at month 12 (p = 0.01) in the Control group. RS (p = 0.001) and MD (p = 0.005) improved at the last follow-up only in the trained group. After training, BCEA 68% and 95% significantly improved (6 and 12 months, p < 0.05). The Biofeedback group had better results in RS (p <= 0.02), CRS (p <= 0.02), and BCEA 68%, 95%, and 99% (p <= 0.01) compared to the Control at all follow-ups. BCVA and MD were better in the Biofeedback group at month 3 (p = 0.01), and month 3 (p = 0.01) and 12 (p = 0.003), respectively. Conclusions: Microperimetric biofeedback can increase retinal sensitivity and stabilize fixation better than the standard care over months after a successful inverted ILM-flap for hMMH.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] SUCCESSFUL CLOSURE OF A LARGE MACULAR HOLE USING THE INVERTED INTERNAL LIMITING MEMBRANE (ILM) FLAP TECHNIQUE
    De Casas, A.
    Abenza, S.
    Javaloy, J.
    Elvira, J. C.
    Marin, J. M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (02) : E76 - E76
  • [2] Inverted internal limiting membrane flap technique for the treatment of high myopic macular hole
    Mete, Maurizio
    Pertile, Grazia
    Prigione, Guido
    Sartore, Mauro
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [3] Inverted internal limiting membrane flap technique for myopic macular hole: A meta-analysis
    Chatziralli, Irini
    Machairoudia, Genovefa
    Kazantzis, Dimitrios
    Theodossiadis, George
    Theodossiadis, Panagiotis
    SURVEY OF OPHTHALMOLOGY, 2021, 66 (05) : 771 - 780
  • [4] INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE VERSUS COMPLETE INTERNAL LIMITING MEMBRANE REMOVAL IN MYOPIC MACULAR HOLE SURGERY
    Mete, Maurizio
    Alfano, Alessandro
    Guerriero, Massimo
    Prigione, Guido
    Sartore, Mauro
    Polito, Antonio
    Pertile, Grazia
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (10): : 1923 - 1930
  • [5] INVERTED INTERNAL LIMITING MEMBRANE (ILM) FLAP TECHNIQUE
    Porter, Ashley
    Lee, Lawrence
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 44 : 144 - 144
  • [6] Microperimetric Biofeedback Training After Successful Inverted Flap Technique for Large Macular Hole
    Sborgia, Giancarlo
    Niro, Alfredo
    Tritto, Tiziana
    Albano, Valeria
    Sborgia, Luigi
    Sborgia, Alessandra
    Donghia, Rossella
    Giancipoli, Ermete
    Coassin, Marco
    Pastore, Valentina
    Giuliani, Gianluigi
    Lorenzi, Umberto
    Romano, Mario R.
    Boscia, Francesco
    Alessio, Giovanni
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (02)
  • [7] The processes of postoperative macular hole closure after inverted internal limiting membrane flap technique. The processes of postoperative macular hole closure after inverted internal limiting membrane flap technique
    Masayuki, Hirano
    Morizane, Yuki
    Kawata, Tetsuhiro
    Kimura, Shuhei
    Hosokawa, Mio
    Shiode, Yusuke
    Doi, Shinichiro
    Hosogi, Mika
    Fujiwara, Atsushi
    Shiraga, Fumio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [8] Temporal inverted internal limiting membrane flap technique for myopic macular hole retinal detachment reconstruction
    Teng, Yan
    Zhang, Xiaoyu
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2024, 52 (01)
  • [9] Inverted internal limiting membrane (ILM) flap technique for macular hole closure: patient selection and special considerations
    Shroff, Daraius
    Gupta, Priyanka
    Atri, Neelam
    Gupta, Charu
    Shroff, Cyrus
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 671 - 678
  • [10] Microperimetric evaluation and predictive factors of visual recovery after successful inverted internal limiting membrane-flap technique for macular hole in high myopic eyes
    Sborgia, Alessandra
    Boscia, Giacomo
    Niro, Alfredo
    Landini, Luca
    Pastore, Valentina
    Albano, Valeria
    Piepoli, Marina
    Donghia, Rossella
    Dore, Stefano
    Viggiano, Pasquale
    Buonamassa, Rosa
    Di Pardo, Camilla
    Molfetta, Teresa
    Coassin, Marco
    Dell'Omo, Roberto
    Boscia, Francesco
    Alessio, Giovanni
    Sborgia, Giancarlo
    FRONTIERS IN MEDICINE, 2023, 10