Comparative assessment of woven endobridge embolization and standard coil occlusion for the treatment of ruptured basilar tip aneurysms

被引:2
|
作者
Celik, Erkan [1 ]
Goertz, Lukas [1 ]
Ozpeynirci, Yigit [2 ]
Schlamann, Marc [1 ]
Dorn, Franziska [3 ]
Lehnen, Nils [3 ]
Siebert, Eberhard [4 ]
Liebig, Thomas [2 ]
Kabbasch, Christoph [1 ]
机构
[1] Univ Hosp Cologne, Dept Radiol & Neuroradiol, Cologne, Germany
[2] Ludwigs Maximilian Univ Munich, Dept Neuroradiol, Munich, Germany
[3] Univ Hosp Bonn, Dept Neuroradiol, Bonn, Germany
[4] Univ Hosp Berlin Charite, Dept Neuroradiol, Berlin, Germany
关键词
Aneurysm; Coiling; WEB embolization; Subarachnoid haemorrhage; Basilar tip; STENT-ASSISTED COILING; UNRUPTURED INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; CEREBRAL ANEURYSMS; FLOW DISRUPTION; WEB; TERM; SAFETY; HEMORRHAGE; EXPERIENCE;
D O I
10.1007/s00234-022-03096-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Endovascular coil occlusion represents the standard treatment for basilar tip aneurysms. Recently, this role has been rivalled by intrasaccular flow disruptors across numerous centres. We retrospectively compared WEB embolization and coiling for the treatment of ruptured basilar tip aneurysms. Methods Patients treated with WEB or coiling at four neurovascular centres were reviewed. Procedure-related complications, clinical outcome, and angiographic results were retrospectively compared. Results The study included 23 patients treated with the WEB (aneurysm size: 6.6 +/- 1.9 mm) and 56 by coiling (aneurysm size: 6.7 +/- 2.5 mm). Stent-assistance was more often necessary with coiling than with WEB embolization (32% vs. 4%, p = 0.009). A modified Rankin scale score <= 2 at discharge had 21 (37.5%) patients in the coiling group and 12 (52.2%) in the WEB group (p = 0.235). Immediate complete and adequate occlusion rates were 52% for the WEB and 87% for coiling. At short-term follow-up, these rates were 87% for the WEB and 72% for coiling, respectively. There was no delayed aneurysm re-bleeding during follow-up. Conclusion Both coiling and WEB seem to prevent rebleeding in ruptured BTA aneurysms. WEB embolization required less frequently stent-support than coiling, potentially advantageous for SAH patients to avoid anti-platelet therapy in the light of concomitant procedures like ventricular drainage.
引用
收藏
页码:765 / 773
页数:9
相关论文
共 50 条
  • [1] Comparative assessment of woven endobridge embolization and standard coil occlusion for the treatment of ruptured basilar tip aneurysms
    Erkan Celik
    Lukas Goertz
    Yigit Ozpeynirci
    Marc Schlamann
    Franziska Dorn
    Nils Lehnen
    Eberhard Siebert
    Thomas Liebig
    Christoph Kabbasch
    Neuroradiology, 2023, 65 : 765 - 773
  • [2] Treatment of coil embolization failed recurrent giant basilar tip aneurysms with bypass and surgical occlusion
    Ramanathan, Dinesh
    Ciporen, Jeremy
    Ghodke, Basavaraj
    Ellenbogen, Richard G.
    Sekhar, Laligam N.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2010, 2 (03) : 237 - 241
  • [3] Coil Embolization for Basilar Artery Tip Aneurysms
    Higa, Takashi
    Takeda, Naoto
    Kato, Koichi
    Sato, Shinsuke
    Okada, Yoshikazu
    CEREBROVASCULAR DISEASES, 2012, 34 : 91 - 92
  • [4] Coil Embolization for Ruptured Basilar Tip Aneurysm After Mechanical Thrombectomy for Acute Basilar Artery Occlusion
    Aketa, Shuta
    Wajima, Daisuke
    Kim, Taekyun
    Tei, Rinsei
    Yonezawa, Taiji
    WORLD NEUROSURGERY, 2016, 93 : 488.e9 - 488.e12
  • [5] Woven EndoBridge (WEB) device in the treatment of ruptured aneurysms
    Youssef, Patrick P.
    Dornbos, David
    Peterson, Jeremy
    Sweid, Ahmad
    Zakeri, Amanda
    Nimjee, Shahid M.
    Jabbour, Pascal
    Arthur, Adam S.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (05) : 443 - +
  • [6] Woven EndoBridge versus stent-assisted coil embolization for the treatment of ruptured wide-necked aneurysms: A multicentric experience
    Rodriguez-Calienes, Aaron
    Vivanco-Suarez, Juan
    Lu, Yujing
    Galecio-Castillo, Milagros
    Gross, Bradley
    Farooqui, Mudassir
    Algin, Oktay
    Feigen, Chaim
    Altschul, David J.
    Ortega-Gutierrez, Santiago
    INTERVENTIONAL NEURORADIOLOGY, 2024,
  • [7] The Woven Endobridge as a treatment for acutely ruptured aneurysms: A review of the literature
    Crinnion, William
    Bhogal, Pervinder
    Makalanda, Hegoda Levansri Dilrukshan
    Wong, Ken
    Arthur, Adam
    Cognard, Christophe
    Henkes, Hans
    Fiorella, Dave
    Pierot, Laurent
    INTERVENTIONAL NEURORADIOLOGY, 2021, 27 (05) : 602 - 608
  • [8] Woven EndoBridge (WEB) Device in the Treatment of Ruptured Intracranial Aneurysms
    Dornbos, David L.
    Youssef, Patrick
    Peterson, Jeremy C.
    Sweid, Ahmad
    Zakeri, Amanda S.
    Nimjee, Shahid M.
    Jabbour, Pascal
    Arthur, Adam S.
    NEUROSURGERY, 2020, 67 : 75 - 75
  • [9] THROMBOSIS IN GIANT BASILAR TIP ANEURYSMS DURING COIL EMBOLIZATION
    RENOWDEN, SA
    MOLYNEUX, AJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1995, 16 (04) : 866 - 871
  • [10] Parallel placement of Woven EndoBridge (WEB) device for the treatment of wide-necked lobulated aneurysms at the basilar tip
    Zhu, Haoyu
    Zhang, Yupeng
    Liang, Shikai
    Jiang, Chuhan
    JOURNAL OF NEURORADIOLOGY, 2024, 51 (05)