Impact of Expanding Access to Continuous Glucose Monitoring Systems Among Insulin Users with Type 1 or Type 2 Diabetes

被引:9
|
作者
Pathak, Shweta [1 ]
Kearin, Kristina [2 ]
Kahkoska, Anna R. [3 ]
Fuller, Kathryn A. [2 ]
Staats, Bradley [4 ]
Albright, Joseph [5 ]
Sturmer, Til [6 ]
Buse, John B. [7 ]
Urick, Benjamin Y. [2 ,8 ]
机构
[1] Univ N Carolina, Cecil G Sheps Ctr Hlth Serv Res, Chapel Hill, NC 27516 USA
[2] Univ N Carolina, Eshelman Sch Pharm, Chapel Hill, NC 27515 USA
[3] Univ N Carolina, Dept Nutr, Gillings Sch Global Publ Hlth, Chapel Hill, NC 27515 USA
[4] Univ N Carolina, Kenan Flagler Business Sch, Chapel Hill, NC 27515 USA
[5] BlueCross BlueShield North Carolina, Durham, NC USA
[6] Univ N Carolina, Dept Epidemiol, Gillings Sch Global Publ Hlth, Chapel Hill, NC 27515 USA
[7] Univ N Carolina, Dept Med, Sch Med, Chapel Hill, NC 27515 USA
[8] Prime Therapeut LLC, Eagan, MN USA
关键词
Continuous glucose monitor use; Type; 1; diabetes; 2;
D O I
10.1089/dia.2022.0418
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Despite increased use of continuous glucose monitoring (CGM) systems, studies to quantify patterns of CGM use are limited. In December 2018, a policy change by a commercial insurer expanded coverage of CGM through the pharmacy benefit, creating an opportunity to evaluate the impact of this change on CGM utilization.Research Design and Methods: Pharmacy and medical claims from 2016 to 2020 were used to estimate the prevalence of CGM use among insulin users with type 1 diabetes mellitus (T1DM) or type 2 diabetes mellitus (T2DM) before and after the policy change. Change in CGM use was assessed using an interrupted time series design.Results: At the beginning of the study period, 18.8% of T1DM patients and 1.2% of T2DM patients used CGM. Use rose to 30.5% and 6.6% in the quarter before the policy change. The policy resulted in an immediate 9.5% (P < 0.0001) and 2.8% (P < 0.0001) change in use and increased the rate of quarterly change by 0.5% (P = 0.002) and 0.8% (P < 0.0001). At the end of the study period, 58.2% and 14.9% of T1DM and T2DM patients used CGM.Conclusion: CGM use significantly increased after addition to the pharmacy benefit. Rate of change in CGM use was lower in T1DM compared to the T2DM population, but overall use remained higher among patients with T1DM. Increased CGM use in the population studied aligns with those whose clinical guidelines suggest would most likely benefit. Additional work is needed to evaluate the impact of this benefit change on health care spending and outcomes.
引用
收藏
页码:169 / 177
页数:9
相关论文
共 50 条
  • [1] EXPANDING ACCESS TO CONTINUOUS GLUCOSE MONITORING IN PATIENTS WITH NEWLY DIAGNOSED TYPE 1 DIABETES
    Wei, Wei
    Newbern, Dorothee
    Shaibi, Gabriel
    Kapadia, Chirag
    Gonsalves, Rob
    HORMONE RESEARCH IN PAEDIATRICS, 2024, 97 : 207 - 208
  • [2] The Expanding Use of Continuous Glucose Monitoring in Type 2 Diabetes
    Dabbagh, Zakery
    McKee, M. Diane
    Pirraglia, Paul A.
    Clements, Karen M.
    Liu, Feifan
    Amante, Daniel J.
    Shukla, Prateek
    Gerber, Ben S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (07) : 510 - 515
  • [3] Utility of Continuous Glucose Monitoring in Type 1 and Type 2 Diabetes
    Toschi, Elena
    Wolpert, Howard
    ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2016, 45 (04) : 895 - +
  • [4] Continuous glucose monitoring systems for type 1 diabetes mellitus
    Langendam, Miranda W.
    Luijf, Yoeri M.
    Hooft, Lotty
    DeVries, J. Hans
    Mudde, Aart H.
    Scholten, Rob J. P. M.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (01):
  • [5] Broadening Access to Continuous Glucose Monitoring for Patients With Type 2 Diabetes
    Peek, Monica E.
    Thomas, Celeste C.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 325 (22): : 2255 - 2257
  • [6] Continuous glucose monitoring in persons with type 2 diabetes not using insulin
    Cowart, Kevin
    Updike, Wendy H.
    Franks, Rachel
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (11) : 1049 - 1055
  • [7] Continuous Glucose Monitoring and Type 1 Diabetes
    Montagnana, Martina
    Lippi, Giuseppe
    Guidi, Gian Cesare
    NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (02): : 190 - 191
  • [8] Continuous glucose monitoring in type 1 diabetes
    Weinzimer S.A.
    Tamborlane W.V.
    Chase P.
    Garg S.K.
    Current Diabetes Reports, 2004, 4 (2) : 95 - 100
  • [9] Continuous glucose monitoring in type 1 diabetes
    Nelly Mauras
    Larry Fox
    Kimberly Englert
    Roy W. Beck
    Endocrine, 2013, 43 : 41 - 50
  • [10] Continuous glucose monitoring in type 1 diabetes
    Mauras, Nelly
    Fox, Larry
    Englert, Kimberly
    Beck, Roy W.
    ENDOCRINE, 2013, 43 (01) : 41 - 50