Improved impurity determination of pure organic substances by differential scanning calorimetry with a dynamic method

被引:0
|
作者
Wang, Yanhong [1 ]
Wang, Haifeng [2 ]
Song, Xiaoping [2 ]
Li, Jia [2 ]
Sun, Guohua [2 ]
机构
[1] Chinese Acad Med Sci, Inst Basic Med Sci, Beijing 100730, Peoples R China
[2] Natl Inst Metrol China, Beijing 100029, Peoples R China
关键词
Differential scanning calorimetry; Impurity determination; Pure organic substance; Reference materials; Dynamic method; CERTIFIED REFERENCE MATERIAL; PURITY DETERMINATION; UNCERTAINTY EVALUATION; CERTIFICATION; CHROMATOGRAPHY;
D O I
10.1007/s44211-022-00205-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Differential scanning calorimetry can be used to measure the impurity contents of pure organic substances on the principle of freezing-point depression. Impurity determination by differential scanning calorimetry with a dynamic method, which has the advantages of speediness and convenience, remains to be explored. Here, a series of acetanilide and dibenzothiophene samples with various purities was prepared through zone melting, and the samples were then analyzed by gas chromatography-mass spectrometry. A modified dynamic method, including encapsulating the analyte in a volatile pan through cold welding, remelting the analyte with a low heating rate, calculating the melted fraction considering the area of the tailing under the heat-flow curve, and reducing the error from solid-solution formation, is proposed. Encapsulating with a volatile pan using a proper torque gave an accurate result. Remelting gave a lower impurity content and a more narrow and sooth peak of heat-flow compared with the first melting. The impurity-content results calculated by the modified method were usually higher than those calculated by the ASTM standard method. For acetanilide and dibenzothiophene with impurity contents of less than 0.30%, the modified dynamic method showed good accuracy. The proposed method is applicable to determination of reference materials of organic substances with high purity owing to its accuracy and convenience.
引用
收藏
页码:87 / 96
页数:10
相关论文
共 50 条
  • [1] Improved impurity determination of pure organic substances by differential scanning calorimetry with a dynamic method
    Yanhong Wang
    Haifeng Wang
    Xiaoping Song
    Jia Li
    Guohua Sun
    Analytical Sciences, 2023, 39 : 87 - 96
  • [2] APPLICATION OF METHOD OF DIFFERENTIAL SCANNING CALORIMETRY FOR STUDIES OF ORGANIC AND POLYMERIC SUBSTANCES
    SAFARYAN, EB
    OGANESYAN, GP
    SAYADYAN, AG
    ARMYANSKII KHIMICHESKII ZHURNAL, 1975, 28 (10): : 836 - 841
  • [3] Improved purity measurement method of organic compounds using differential scanning calorimetry
    Yamamoto, K
    Momota, M
    Kitamura, H
    Narita, K
    ANALYTICAL SCIENCES, 1996, 12 (06) : 893 - 898
  • [4] AN IMPROVED METHOD OF ANALYZING CURVES IN DIFFERENTIAL SCANNING CALORIMETRY
    BRENNAN, WP
    MILLER, B
    WHITWELL, JC
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1969, 8 (02): : 314 - &
  • [5] DYNAMIC DIFFERENTIAL SCANNING CALORIMETRY
    DIVITO, MP
    CASSEL, RB
    MARGULIES, M
    GOODKOWSKY, S
    AMERICAN LABORATORY, 1995, 27 (12) : 28 - &
  • [6] DETERMINATION OF THE KINETIC-PARAMETERS FOR THE POLYMERIZATION OF A POLYURETHANE USING AN IMPROVED METHOD OF DIFFERENTIAL SCANNING CALORIMETRY
    HERNANDEZSANCHEZ, F
    VERAGRAZIANO, R
    JOURNAL OF APPLIED POLYMER SCIENCE, 1992, 46 (04) : 571 - 580
  • [7] DETERMINATION OF AMYLOSE BY DIFFERENTIAL SCANNING CALORIMETRY
    SIEVERT, D
    HOLM, J
    STARCH-STARKE, 1993, 45 (04): : 136 - 139
  • [8] Comparison between modulated differential scanning calorimetry (MDSC) and dynamic differential scanning calorimetry (DDSC)
    Fuller, LC
    Judovits, L
    MATERIALS CHARACTERIZATION BY DYNAMIC AND MODULATED THERMAL ANALYTICAL TECHNIQUES, 2001, 1402 : 89 - 100
  • [9] Fast method for the experimental determination of vaporization enthalpy by differential scanning calorimetry
    Fidel. O. Cedeńo
    Maria. M. Prieto
    Aranzazu Espina
    Jose. R. García
    Journal of Thermal Analysis and Calorimetry, 2003, 73 : 775 - 781
  • [10] A rapid method for the determination of amylose content by using Differential Scanning Calorimetry
    Mestres, C
    Matencio, F
    Pons, B
    Yajid, M
    Fliedel, G
    STARCH-STARKE, 1996, 48 (01): : 2 - 6