Effectiveness of near-UVA in SARS-CoV-2 inactivation

被引:2
|
作者
Frilli, Eleonora [1 ]
Amodeo, Davide [2 ]
Cevenini, Gabriele [3 ]
Nante, Nicola [1 ,2 ]
Messina, Gabriele [1 ,2 ]
机构
[1] Univ Siena, Postgrad Sch Publ Hlth, Siena, Italy
[2] Univ Siena, Hyg & Prevent Med, Siena, Italy
[3] Univ Siena, Dept Med Biotechnol, Siena, Italy
来源
EPIDEMIOLOGY AND INFECTION | 2023年 / 151卷
关键词
COVID-19; virus infection; SARS-CoV-2; Cell Colture; near-UVA; UVC; Disinfection; Hygiene; Prevention; 405 NM LIGHT; BLUE-LIGHT; EFFICACY;
D O I
10.1017/S0950268823000560
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
This experimental study aimed to determine the activity of a near-UVA (405 nm) LED ceiling system against the SARS-CoV-2 virus. The ceiling system comprised 17 near-UVA LED lights with a radiant power of 1.1 W/each centred at 405 nm wavelength. A 96-multiwell plate, fixed to a wooden base, was inoculated with suspensions of VERO E6 cell cultures infected with SARS-CoV-2 virus and irradiated at a distance of 40 cm with a dose of 20.2 J/cm(2) for 120 min. The collected suspensions were transferred to VERO cell culture plates and incubated for 3 days. The maximum measurable log reduction obtained, starting from a concentration of 10(7.2) TCID50/mL, was 3.0 log(10) and indicated inhibition of SARS-CoV-2 replication by the near-UVA LED ceiling system. Near-UVA light at a 405-nm wavelength is emerging as a potential alternative treatment for localised infections and environmental decontamination because it is far less harmful to living organisms' cells than UV-C irradiation.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Inactivation of SARS-CoV-2 Laboratory Specimens
    Haddock, Elaine
    Feldmann, Friederike
    Shupert, W. Lesley
    Feldmann, Heinz
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2021, 104 (06): : 2195 - 2198
  • [2] PMMA Microcapsules for the Inactivation of SARS-CoV-2
    Sousa, Vania I. .
    Parente, Joana F.
    Marques, Juliana F.
    Calcada, Carla
    Veiga, Maria I.
    Osorio, Nuno S.
    Tavares, Carlos J.
    ACS OMEGA, 2022, : 22383 - 22393
  • [3] Assessment of inactivation procedures for SARS-CoV-2
    Auerswald, Heidi
    Yann, Sokhoun
    Dul, Sokha
    In, Saraden
    Dussart, Philippe
    Martin, Nicholas J.
    Karlsson, Erik A.
    Garcia-Rivera, Jose A.
    JOURNAL OF GENERAL VIROLOGY, 2021, 102 (03):
  • [4] Inactivation of SARS-CoV-2 by gamma irradiation
    Jain, Rajlaxmi
    Sarkale, Prasad
    Mali, Deepak
    Shete, Anita M.
    Patil, Deepak Y.
    Majumdar, Triparna
    Suryawanshi, Annasaheb
    Patil, Savita
    Mohandas, Sreelekshmy
    Yadav, Pragya D.
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2021, 153 (1-2) : 196 - 198
  • [5] Inactivation of SARS-CoV-2 in Water by Chlorination
    Samendra Sherchan
    Luisa A. Ikner
    Charles P. Gerba
    Food and Environmental Virology, 2023, 15 : 262 - 264
  • [6] Inactivation of SARS-CoV-2 by Ozonated Glycerol
    Takeda, Yohei
    Jamsransuren, Dulamjav
    Makita, Yoshimasa
    Kaneko, Akihiro
    Matsuda, Sachiko
    Ogawa, Haruko
    Oh, Hourei
    FOOD AND ENVIRONMENTAL VIROLOGY, 2021, 13 (03) : 316 - 321
  • [7] Inactivation of SARS-CoV-2 in Water by Chlorination
    Sherchan, Samendra
    Ikner, Luisa A.
    Gerba, Charles P.
    FOOD AND ENVIRONMENTAL VIROLOGY, 2023, 15 (03) : 262 - 264
  • [8] Inactivation of SARS-CoV-2 by Ozonated Glycerol
    Yohei Takeda
    Dulamjav Jamsransuren
    Yoshimasa Makita
    Akihiro Kaneko
    Sachiko Matsuda
    Haruko Ogawa
    Hourei Oh
    Food and Environmental Virology, 2021, 13 : 316 - 321
  • [9] Rapid Inactivation of SARS-CoV-2 with Ozonated Water
    Inagaki, Hiroko
    Saito, Akatsuki
    Sudaryatma, Putu Eka
    Sugiyama, Hironobu
    Okabayashi, Tamaki
    Fujimoto, Shouichi
    OZONE-SCIENCE & ENGINEERING, 2021, 43 (03) : 208 - 212
  • [10] Cold atmospheric plasma for SARS-CoV-2 inactivation
    Chen, Zhitong
    Garcia, Gustavo, Jr.
    Arumugaswami, Vaithilingaraja
    Wirz, Richard E.
    PHYSICS OF FLUIDS, 2020, 32 (11)