Carbon Nanotube Fiber-Based Flexible Microelectrode for Electrochemical Glucose Sensors

被引:39
|
作者
Muqaddas, Sheza [1 ]
Javed, Mohsin [2 ]
Nadeem, Sohail [2 ]
Asghar, Muhammad Adeel [1 ]
Haider, Ali [1 ]
Ahmad, Muhammad
Ashraf, Ahmad Raza [3 ]
Nazir, Arif [3 ]
Iqbal, Munawar [4 ]
Alwadai, Norah [5 ]
Ahmad, Azhar [3 ]
Ali, Abid [3 ]
机构
[1] Quaid I Azam Univ, Dept Chem, Islamabad 45320, Pakistan
[2] Univ Management & Technol, Sch Sci, Dept Chem, Lahore 54770, Pakistan
[3] Univ Lahore, Dept Chem, Lahore 54590, Pakistan
[4] Univ Educ, Dept Chem, Div Sci & Technol, Lahore 54770, Pakistan
[5] Princess Nourah bint Abdulrahman Univ, Coll Sci, Dept Phys, Riyadh 11671, Saudi Arabia
来源
ACS OMEGA | 2023年 / 8卷 / 02期
关键词
ONE-STEP SYNTHESIS; ELECTRODE; NANOPARTICLES; COMPOSITE; PLATINUM; ARRAYS; OXIDE; NANOSTRUCTURES; GROWTH; ALLOY;
D O I
10.1021/acsomega.2c06594
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrochemical sensors are gaining significant demand for real-time monitoring of health-related parameters such as temperature, heart rate, and blood glucose level. A fiber-like microelectrode composed of copper oxide-modified carbon nanotubes (CuO@CNTFs) has been developed as a flexible and wearable glucose sensor with remarkable catalytic activity. The unidimensional structure of CNT fibers displayed efficient conductivity with enhanced mechanical strength, which makes these fibers far superior as compared to other fibrous-like materials. Copper oxide (CuO) nanoparticles were deposited over the surface of CNT fibers by a binder-free facile electrodeposition approach followed by thermal treatment that enhanced the performance of non-enzymatic glucose sensors. Scanning electron microscopy and energy-dispersive X-ray analysis confirmed the successful deposition of CuO nanoparticles over the fiber surface. Amperometric and voltammetric studies of fiber-based microelectrodes (CuO@CNTFs) toward glucose sensing showed an excellent sensitivity of similar to 3000 mu A/mM cm(2), a low detection limit of 1.4 mu M, and a wide linear range of up to 13 mM. The superior performance of the microelectrode is attributed to the synergistic effect of the electrocatalytic activity of CuO nanoparticles and the excellent conductivity of CNT fibers. A lower charge transfer resistance value obtained via electrochemical impedance spectroscopy (EIS) also demonstrated the superior electrode performance. This work demonstrates a facile approach for developing CNT fiber-based microelectrodes as a promising solution for flexible and disposable non-enzymatic glucose sensors.
引用
收藏
页码:2272 / 2280
页数:9
相关论文
共 50 条
  • [1] Design of carbon nanotube fiber microelectrode for glucose biosensing
    Zhu, Zhigang
    Garcia-Gancedo, Luis
    Flewitt, Andrew J.
    Moussy, Francis
    Li, Yali
    Milne, William I.
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2012, 87 (02) : 256 - 262
  • [2] Expanded Carbon Nanotube Fiber at the Liquid-Air Interface for High-Performance Fiber-Based Supercapacitors and Electrochemical Sensors
    Zhou, Yue
    Cai, Yu
    Tu, Tingting
    Zhang, Shanshan
    Li, Tianyu
    Fang, Lu
    Wang, Dong
    Liang, Yitao
    Wang, Zhaoyang
    Jiang, Yu
    Zhou, Congcong
    Liang, Bo
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (35) : 41839 - 41849
  • [3] FRACTURED CARBON FIBER-BASED BIOSENSOR FOR GLUCOSE
    FURBEE, JW
    KUWANA, T
    KELLY, RS
    ANALYTICAL CHEMISTRY, 1994, 66 (09) : 1575 - 1577
  • [4] Carbon nanotube based electronic and electrochemical sensors
    Moulton, SE
    Minett, AI
    Wallace, GG
    SENSOR LETTERS, 2005, 3 (03) : 183 - 193
  • [5] Flexible biological sensors based on carbon nanotube films
    Akhmadishina K.F.
    Bobrinetskii I.I.
    Komarov I.A.
    Malovichko A.M.
    Nevolin V.K.
    Petukhov V.A.
    Golovin A.V.
    Zalevskii A.O.
    Nanotechnologies in Russia, 2013, 8 (11-12): : 721 - 726
  • [6] Optical fiber-based sensors with flexible encapsulation for pavement behavior monitoring
    Liu, Wanqiu
    Wang, Huaping
    Zhou, Zhi
    Xing, Xiaoying
    Cao, Dandan
    Jiang, Zhen
    STRUCTURAL CONTROL & HEALTH MONITORING, 2015, 22 (02): : 301 - 313
  • [7] Flexible Fiber-based Triboelectric Generator for Self-powered Sensors
    Park, Jiwon
    Choi, A. Young
    Lee, Chang Jun
    Kim, Youn Tae
    2016 IEEE SENSORS, 2016,
  • [8] Flexible nanohybrid microelectrode based on carbon fiber wrapped by gold nanoparticles decorated nitrogen doped carbon nanotube arrays: In situ electrochemical detection in live cancer cells
    Zhang, Yan
    Xiao, Jian
    Sun, Yimin
    Wang, Lu
    Dong, Xulin
    Ren, Jinghua
    He, Wenshan
    Xiao, Fei
    BIOSENSORS & BIOELECTRONICS, 2018, 100 : 453 - 461
  • [9] Carbon-nanotube based electrochemical sensors.
    Wang, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U939 - U939
  • [10] Diamond and carbon nanotube glucose sensors based on electropolymerization
    Loh, KP
    Zhao, SL
    De Zhang, W
    DIAMOND AND RELATED MATERIALS, 2004, 13 (4-8) : 1075 - 1079