Comparison of the clinical efficacy of three cannulated screws with parallel distribution and inverted triangular distribution in the treatment of femoral neck fractures in the elderly

被引:2
|
作者
Liu, Jiuxiang [1 ]
Zuo, Qiang [1 ]
Zhou, Hao [1 ]
Huang, Xiaowen [1 ,2 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Jiangsu Prov Hosp, Dept Orthoped, Nanjing 210029, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 1, Jiangsu Prov Hosp, Dept Orthoped, 300 Guangzhou Rd, Nanjing 210029, Jiangsu, Peoples R China
关键词
Femoral neck fracture; parallel distribution; inverted triangular distribution; cannulated screw; elderly; TOTAL HIP-ARTHROPLASTY; FIXATION; SYSTEM;
D O I
10.3892/etm.2023.12197
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of the present study was to investigate the clinical efficacy of three cannulated screws with parallel distribution in comparison with the 'gold standard' of inverting three cannulated screws with triangular distribution, in the treatment of femoral neck fractures in the elderly. A total of 106 elderly patients with femoral neck fractures treated at the Department of Orthopedics of the First Affiliated Hospital of Nanjing Medical University (Jiangsu Provincial Hospital) from October 2018 to March 2020 were retrospectively analyzed and divided into groups A and B. Group A consisted of 51 patients with a mean age of 73.3 +/- 6.8 years; and group B consisted of 55 patients with a mean age of 74.5 +/- 7.3 years. Group A was treated with closed reduction + inverted triangular distribution of three cannulated screws, while group B was treated with closed reduction + parallel distribution of three cannulated screws, and the general surgical conditions, including fracture reduction quality, fracture healing, incidence of avascular necrosis of the femoral head, and functional recovery scale (FRS) score of hip joint function were assessed in both groups. All patients were followed up for an average of 14.8 months. Compared with group A, group B had significant advantages in operation time, number of times intraoperative fluoroscopy was performed, number of intraoperative guide wire adjustments, and proportion of postoperative referrals to the intensive care unit (P<0.05). There were no significant differences in fracture reduction quality, fracture healing, incidence of avascular necrosis of the femoral head, and FRS score of hip joint function between groups A and B (P>0.05). For elderly patients with femoral neck fractures, distributing three cannulated screws in parallel after closed reduction achieved similar clinical efficacy to 'gold standard' inverted triangular distribution, and had obvious advantages in operation time, with significantly reduced surgical difficulty. This procedure is therefore deemed worthy of promotion and clinical application in the primary hospitals of China.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of Early Clinical Results for Femoral Neck System and Cannulated Screws in the Treatment of Unstable Femoral Neck Fractures
    Zhou, Xiao-Qiang
    Li, Zhi-Qiang
    Xu, Ren-Jie
    She, Yuan-Shi
    Zhang, Xiang-Xin
    Chen, Guang-Xiang
    Yu, Xiao
    ORTHOPAEDIC SURGERY, 2021, 13 (06) : 1802 - 1809
  • [2] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Huang, Shaolong
    Zhang, Yazhong
    Zhang, Xu
    Zhou, Chengqiang
    Li, Wenbo
    Wang, Yunqing
    Wang, Bin
    Zhu, Ziqiang
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [3] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Shaolong Huang
    Yazhong Zhang
    Xu Zhang
    Chengqiang Zhou
    Wenbo Li
    Yunqing Wang
    Bin Wang
    Ziqiang Zhu
    BioMedical Engineering OnLine, 22
  • [4] Comparison of the clinical efficacy of a femoral neck system versus cannulated screws in the treatment of femoral neck fracture in young adults
    Changjun He
    Yao Lu
    Qian Wang
    Cheng Ren
    Ming Li
    Mingyi Yang
    Yibo Xu
    Zhong Li
    Kun Zhang
    Teng Ma
    BMC Musculoskeletal Disorders, 22
  • [5] Comparison of the clinical efficacy of a femoral neck system versus cannulated screws in the treatment of femoral neck fracture in young adults
    He, Changjun
    Lu, Yao
    Wang, Qian
    Ren, Cheng
    Li, Ming
    Yang, Mingyi
    Xu, Yibo
    Li, Zhong
    Zhang, Kun
    Ma, Teng
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [6] Comparison of the Effect of Rhombic and Inverted Triangle Configurations of Cannulated Screws on Internal Fixation of Nondisplaced Femoral Neck Fractures in Elderly Patients
    Zhu, Jian
    Deng, Xiangtian
    Hu, Hongzhi
    Cheng, Xiaodong
    Tan, Zhanchao
    Zhang, Yingze
    ORTHOPAEDIC SURGERY, 2022, 14 (04) : 720 - 729
  • [7] Proximal Femoral Locking Plate With Cannulated Screws for the Treatment of Femoral Neck Fractures
    Lin, Dasheng
    Lian, Kejian
    Ding, Zhenqi
    Zhai, Wenliang
    Hong, Jiayuan
    ORTHOPEDICS, 2012, 35 (01) : E1 - E5
  • [8] Comparison of oblique triangular configuration and inverted equilateral triangular configuration of three cannulated screws in treating unstable femoral neck fracture: A finite element analysis
    Zhang, Ru-Yi
    Li, Jian-Tao
    Zhao, Jing-Xin
    Zhao, Zhe
    Zhang, Li-Cheng
    Yun, Cai
    Su, Xiu-Yun
    Tang, Pei-Fu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 353 - 361
  • [9] Biomechanical and clinical evaluation of interlocking hip screw in Pauwels III femoral neck fractures: A comparison with inverted triangle cannulated screws
    Zhang, Jian
    Jiang, Haozheng
    Dai, Wei
    Hersi, Salad Abdirahman
    Cheong, John Chun Tien Chui Wan
    Chu, Zhenchen
    Lou, Zhiyuan
    Zhang, Deqiang
    Liu, Changjian
    Tian, Kang
    Tang, Xin
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [10] Fixation of femoral neck fractures using divergent versus parallel cannulated screws
    Papanastassiou I.D.
    Mavrogenis A.F.
    Kokkalis Z.T.
    Nikolopoulos K.
    Skourtas K.
    Papagelopoulos P.J.
    Journal of Long-Term Effects of Medical Implants, 2011, 21 (01) : 63 - 69