The Impact of Medium Cut-Off Dialyzers on Malnutrition-Inflammation Scores in Maintenance Hemodialysis Patients

被引:1
|
作者
Sahutoglu, Tuncay [1 ]
Erinc, Osman [2 ]
Avsar, Fevzi Necati [2 ]
机构
[1] Mehmet Akif Inan Educ & Res Hosp, Nephrol, Sanliurfa, Turkiye
[2] Mehmet Akif Inan Educ & Res Hosp, Internal Med, Sanliurfa, Turkiye
关键词
Medium cut-off dialyzer; Theranova; High-flux dialyzer; Hemodialysis; Malnutrition-inflammation score; MORTALITY; ALBUMIN;
D O I
10.1159/000535268
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Medium cut-off (MCO) membranes may be able to remove middle-large uremic toxins that are retained in the body, which has been linked to various risk factors including malnutrition-inflammation score (MIS). The effect of MCO dialyzers on MIS has been studied. Methods: This single-center exploratory prospective observational study enrolled maintenance hemodialysis patients who underwent dialysis using either MCO (Theranova 400) or high-flux (FX80) membranes as part of their regular care. Measurements of MIS, body weight, height, body mass index, and various biochemical markers were taken at the beginning and conclusion of the study. Results: This study included 50 patients who were treated with either the Theranova 400 (n = 25) or the FX80 (n = 25) for a period of 6 months. The two groups were similar in terms of demographics, duration of hemodialysis treatment, and baseline biochemical test results. Theranova 400 had no significant impact on the median MIS (6 [6-10] vs. 7 [5-10], p 0.575) and serum albumin levels (4.07 [3.92-4.22] vs. 4.04 [3.85-4.30], p 0.689), while the FX80 resulted in a significant increase in MIS (6 [5-8] vs. 8 [6-10], p 0.033) and a significant decrease in serum albumin levels (4.23 [4.03-4.36] vs. 3.98 [3.77-4.12], p 0.027) at the end of the study. Discussion/Conclusion: After 6 months of treatment, the MCO dialyzer did not demonstrate a statistically significant difference in the MIS when compared to the high-flux dialyzer. However, MIS worsening was significantly less in the MCO group, indicating the potential benefits of MCO membranes in maintaining nutritional status. Further research is required to validate these results.
引用
收藏
页码:219 / 228
页数:10
相关论文
共 50 条
  • [1] Clinical utility of malnutrition-inflammation score in maintenance hemodialysis patients: Focus on identifying the best cut-off point
    Ho, Li-chun
    Wang, His-Hao
    Peng, Yu-Sen
    Chiang, Chih-Kang
    Huang, Jeng-Wen
    Hung, Kuan-Yu
    Hu, Fu-Chang
    Wu, Kwan-Dun
    AMERICAN JOURNAL OF NEPHROLOGY, 2008, 28 (05) : 840 - 846
  • [2] Performance of hemodialysis with novel medium cut-off dialyzers
    Kirsch, Alexander H.
    Lyko, Raphael
    Nilsson, Lars-Goran
    Beck, Werner
    Amdahl, Michael
    Lechner, Petra
    Schneider, Andreas
    Wanner, Christoph
    Rosenkranz, Alexander R.
    Krieter, Detlef H.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2017, 32 (01) : 165 - 172
  • [3] PERFORMANCE OF MEDIUM CUT-OFF DIALYZERS IN EXPANDED HEMODIALYSIS PATIENTS IN COLOMBIA
    D'Achiardi, Roberto
    Zuniga, Eduardo
    Molano, Alejandra
    Tran, Ha
    Parreno, Rhea
    Vesga, Jasmin
    Rivera, Angela
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 1390 - 1390
  • [4] Medium cut-off dialyzers in a large population of hemodialysis patients in Colombia: COREXH registry
    Bunch, Alfonso
    Sanchez, Ricardo
    Nilsson, Lars-Goran
    Bernardo, Angelito A.
    Vesga, Jasmin, I
    Ardila, Fredy
    Guerrero, Ivan M.
    Sanabria, Rafael M.
    Rivera, Angela S.
    THERAPEUTIC APHERESIS AND DIALYSIS, 2021, 25 (01) : 33 - 43
  • [5] Efficacy of medium cut-off dialyzers and comparison with high-flux dialyzers in patients on maintenance hemodialysis: A systematic review and meta-analysis
    Yang, Jia
    Ke, Guibao
    Liao, Yuanjiang
    Guo, Yong
    Gao, Xiaoling
    THERAPEUTIC APHERESIS AND DIALYSIS, 2022, 26 (04) : 756 - 768
  • [6] Effects of medium cut-off dialysis membranes on inflammation and oxidative stress in patients on maintenance hemodialysis
    Yeter, Hasan Haci
    Korucu, Berfu
    Akcay, Omer Faruk
    Derici, Kursat
    Derici, Ulver
    Arinsoy, Turgay
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2020, 52 (09) : 1779 - 1789
  • [7] Effects of medium cut-off dialysis membranes on inflammation and oxidative stress in patients on maintenance hemodialysis
    Hasan Haci Yeter
    Berfu Korucu
    Omer Faruk Akcay
    Kursat Derici
    Ulver Derici
    Turgay Arinsoy
    International Urology and Nephrology, 2020, 52 : 1779 - 1789
  • [8] Depression, quality of life and malnutrition-inflammation scores in hemodialysis patients
    Ibrahim, Salwa
    El Salamony, Omima
    AMERICAN JOURNAL OF NEPHROLOGY, 2008, 28 (05) : 784 - 791
  • [9] MEDIUM CUT-OFF VERSUS HEMODIAFILTRATION DIALYZERS
    Jesus Broseta, Jose
    Rodas, Lida
    Arias, Marta
    Fontsere, Nestor
    Vera, Manel
    Guillen, Elena
    Xipell, Marc
    Molina, Alicia
    Montagud, Enrique
    Hermida, Evelyn
    Maduell, Francesc
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34 : 520 - 520
  • [10] Comparison of four medium cut-off dialyzers
    Krieter, Detlef H.
    Wanner, Christoph
    CLINICAL KIDNEY JOURNAL, 2023, 16 (05) : 879 - 880