Thermal spray processes influencing surface chemistry and in-vitro hemocompatibility of hydroxyapatite-based orthopedic implants

被引:11
|
作者
Shankar, Deep [1 ]
Jayaganesh, K. [1 ]
Gowda, Niranjan [2 ]
Lakshmi, K. S. [2 ]
Jayanthi, K. J. [2 ]
Jambagi, Sudhakar C. [1 ]
机构
[1] Natl Inst Technol Karnataka, Dept Mech Engn, Surface Engn Lab, Srinivasnagar 575025, Surathkal, India
[2] Sanjay Gandhi Inst Trauma & Orthoped, Dept Pathol, Pathol Lab, Jayanagar East 560011, Bengaluru, India
来源
BIOMATERIALS ADVANCES | 2024年 / 158卷
关键词
Thermal spray; High-velocity oxy-fuel; Hydroxyapatite; Hemocompatibility; Hemolysis; Thrombogenicity; CALCIUM-PHOSPHATE COATINGS; MECHANICAL-PROPERTIES; PROTEIN ADSORPTION; CARBON NANOTUBE; THICKNESS; ALLOY; MICROSTRUCTURE; TITANIUM; BEHAVIOR; OSSEOINTEGRATION;
D O I
10.1016/j.bioadv.2024.213791
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Orthopedic implants made from titanium are a popular choice in the medical field because of their remarkable strength-to-weight ratio. Nevertheless, they may not interact well with human blood, resulting in thrombosis and hemolysis. In fact, non-hemocompatibility is believed to be responsible for about 31 % of medical device failures in the US alone, requiring painful and expensive revision surgery. To address this issue, bioactive hydroxyapatite coatings are applied to Ti-6Al-4V implants using thermal spray techniques. However, the temperature used during thermal processing impacts the coating's surface properties, affecting the mechanical and biological properties. Furthermore, the effectiveness of HA coatings on titanium for orthopedic applications has not been validated by biocompatibility tests, particularly hemocompatibility. In this study, we aimed to investigate the relative efficacy of three thermal spray processes of different temperature ranges: Atmospheric plasma spray (APS) (high temperature), Flame spray (FS) (moderate temperature), and High-Velocity Oxy-Fuel spray (HVOF) (low temperature), and study their impact on coating's surface properties, affecting blood components and implant's strength. The crystallinity of the HA coating increased by 32 % with a decrease in the operating temperature (APS < FS < HVOF). HVOF coating exhibited a similar to 34 % and similar to 120 % improvement in adhesion strength and similar to 31 % and 59 % increment in hardness compared to APS and FS coating, respectively, attributed to its low porosity, low coating thickness (similar to 55 mu m), and high degree of crystallinity. The HVOF coating showcased a significant increase in non-hemolytic behavior, with hemolysis rates similar to 8 and similar to 11 times lower than APS and FS coatings, respectively, owing to its smooth texture and high degree of crystallinity (p < 0.05). Furthermore, the HVOF coating exhibited minimal blood clotting based on the whole blood clotting assay, again confirmed by PT and aPTT assays showing delayed clotting time, indicating its non-thrombogenic behavior. The number of platelets adhered to the three coatings showed no significant difference compared to Ti-6Al-4V. APS and FS coatings showed low platelet activation, unlike HVOF coating and titanium, which revealed round platelets, similar to the negative control. Neither titanium nor HA coatings exhibited antibacterial properties, which may be due to their high affinity for organic substances, which promotes bacterial adhesion and replication. Among the three thermal processes, HVOF coating displayed good apatite growth, non-hemolytic, and non-thrombogenicity with no platelet activation owing to its low processing temperature, high degree of crystallinity (89.7 %), hydrophilicity, smooth (similar to 4 mu m) and dense (similar to 97 %) microstructural properties. The results demonstrated that the HVOF-HA coating presented in this work meets the hemocompatible requirements and shows promise for prospective application as an orthopedic implant. Furthermore, this study has the potential to significantly reduce the use of animals in in-vivo research and improve their welfare while also cutting costs.
引用
收藏
页数:22
相关论文
共 6 条
  • [1] In-vitro comparison of hydroxyapatite coatings obtained by cold spray and conventional thermal spray technologies
    Vilardell, A. M.
    Cinca, N.
    Garcia-Giralt, N.
    Dosta, S.
    Cano, I. G.
    Nogues, X.
    Guilemany, J. M.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 107 (107):
  • [2] Improvements in bioactivity, blood compatibility, and wear resistance of thermally sprayed carbon nanotube reinforced hydroxyapatite-based orthopedic implants
    Shankar, Deep
    Jambagi, Sudhakar C.
    TRIBOLOGY INTERNATIONAL, 2024, 197
  • [3] Incorporation of Plant Extracted Hydroxyapatite and Chitosan Nanoparticles on the Surface of Orthodontic Micro-Implants: An In-Vitro Antibacterial Study
    Alhazmi, Anwar S.
    Syame, Sohier M.
    Mohamed, Wael S.
    Hakim, Ashraf S.
    MICROORGANISMS, 2022, 10 (03)
  • [4] A new spray-based method for the in-vitro development of dry-surface biofilms
    Christine, Esther
    Olive, Claude
    Louisin, Myriam
    Drame, Moustapha
    Marion-Sanchez, Karine
    MICROBIOLOGYOPEN, 2023, 12 (01):
  • [5] In-vitro viability of laser cladded Fe-based metallic glass as a promising bioactive material for improved osseointegration of orthopedic implants
    Ibrahim, Mahmoud Z.
    Halilu, Ahmed
    Sarhan, Ahmed A.D.
    Kuo, T.Y.
    Yusuf, Farazila
    Shaikh, M.O.
    Hamdi, M.
    Medical Engineering and Physics, 2022, 102
  • [6] In-vitro viability of laser cladded Fe-based metallic glass as a promising bioactive material for improved osseointegration of orthopedic implants
    Ibrahim, Mahmoud Z.
    Halilu, Ahmed
    Sarhan, Ahmed A. D.
    Kuo, T. Y.
    Yusuf, Farazila
    Shaikh, M. O.
    Hamdi, M.
    MEDICAL ENGINEERING & PHYSICS, 2022, 102