Effect of different implant angulations on the biomechanical performance of prosthetic screws in two implant-supported, screw-retained prostheses: A numerical and experimental study

被引:2
|
作者
Chen, Jianyu [1 ]
Guo, Jiaer [1 ]
Yang, Lijia [2 ]
Wang, Lin [1 ,4 ]
Zhang, Xiao [3 ]
机构
[1] Sun Yat Sen Univ, Hosp Stomatol, Guangdong Prov Key Lab Stomatol, Dept Oral Implantol,Guanghua Sch Stomatol, Guangzhou, Peoples R China
[2] Jinan Univ, Coll Stomatol, Guangzhou, Peoples R China
[3] Foshan Angels Biotechnol Co Ltd, Foshan, Peoples R China
[4] Sun Yat Sen Univ, Hosp Stomatol, Guanghua Sch Stomatol, Guangdong Prov Key Lab Stomatol, Guangzhou 510055, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 130卷 / 02期
基金
中国国家自然科学基金;
关键词
FIXED DENTAL PROSTHESES; COMPLICATIONS; CANTILEVER; SURVIVAL; CROWNS; CEMENT;
D O I
10.1016/j.prosdent.2023.06.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. A mesiodistal angle frequently forms between 2 splinted implant-supported, screw-retained fixed dental prostheses (TIS-FDPs). Mechanical complications commonly occur in prosthetic screws. Studies regarding the effect of the degree of implant angulation on the biomechanical performance of prosthetic screws in TIS-FDPs are sparse.Purpose. The purpose of this numerical and experimental study was to investigate the effects of different implant angulations on the biomechanical performance, including stress distribution, stability of the screw joint, and surface morphology change of the prosthetic screws in TIS-FDPs.Material and methods. TIS-FDPs were classified into 4 groups: 0, 10, 20, and 30 degrees based on the degree of mesiodistal angle between the long axes of the 2 implants. In the finite element analysis (FEA), 4 series of 3D models were constructed and loaded with simulated occlusal forces. The von Mises stresses and rotational angles of the prosthetic screws were then calculated. In the mechanical test, each group of 5 TIS-FDPs with 10 prosthetic screws was tested under 1 million loading cycles by using a universal testing machine. The removal torque values (RTVs) and the surface roughness of the prosthetic screws were measured after cyclic loading. The normality of the outcome variables was assessed by the Shapiro-Wilk test. Analysis of variance and the Kruskal-Wallis test were used for further analysis (& alpha;=.05).Results. The FEA results showed that the von Mises stresses of the prosthetic screws were concentrated in the first screw thread crest engaged with the abutment, and the maximum values of the threads and the rotation angles of the prosthetic screws increased in the 2-implant mesiodistal angulation from 0 to 30 degrees. The mechanical tests showed that the RTVs of the prosthetic screws in each group were not significantly different after 1 million loading cycles (P=.107). The surface roughness of the crest of the first 2 threads of the prosthetic screws in the 30-degree group changed significantly compared with those in the other groups.Conclusions. When TIS-FDPs were delivered, larger angulations of the 2 splinted implants seemed to increase the stress concentrated on the crest of the first engaged thread and the rotation angles of the prosthetic screws. After 1 million loading cycles, significant surface adhesive wear was identified on the crest of the first 2 threads of the prosthetic screws in the 30-degree group compared with groups with a smaller angulation.
引用
收藏
页码:240.e1 / 240.e10
页数:10
相关论文
共 50 条
  • [1] The Effect of Two Different Immediate Loading Protocols in Implant-Supported Screw-Retained Prostheses
    Khorshid, Heba E.
    Hamed, Hamdy Aboul Fotouh
    Aziz, Essam A.
    IMPLANT DENTISTRY, 2011, 20 (02) : 157 - 166
  • [2] An Alternative Design to Overcome the Problem of Unfavorable Implant Angulations for a Screw-Retained, Implant-Supported Fixed Prosthesis: Two Clinical Reports
    Chatzistavrianou, Despoina
    Shahdad, Shakeel
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (07): : 589 - 593
  • [3] Efficacy of Sealing Agents on Preload Maintenance of Screw-Retained Implant-Supported Prostheses
    Seloto, Camila Berbel
    Strazzi Sahyon, Henrico Badaoui
    dos Santos, Paulo Henrique
    Delben, Juliana Aparecida
    Assuncao, Wirley Goncalves
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (01) : 123 - 126
  • [4] Prosthetic Complications of Single Screw-Retained Implant-Supported Metal-Ceramic Fixed Prostheses: A Retrospective Observational Study
    Palma-Carrio, Cristina
    Macconi, Andrea
    Rubert-Aparici, Andrea
    Vidal-Peiro, Paula
    Menendez-Nieto, Isabel
    Blaya-Tarraga, Juan Antonio
    INTERNATIONAL JOURNAL OF DENTISTRY, 2024, 2024
  • [5] New abutment for a screw-retained, implant-supported crown
    Prisco, R
    Morgano, SM
    D'Amato, S
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (01): : 30 - 33
  • [6] Straightforward tip for identifying the type of screwdriver needed for screw-retained implant-supported prostheses
    Real-Voltas, Francisco
    Figueras-Alvarez, Oscar
    Barrocal-Rodriguez, Susana
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 539 - 540
  • [7] Effect of Abutment Screw Design and Crown/Implant Ratio on Preload Maintenance of Single-Crown Screw-Retained Implant-Supported Prostheses
    Rodrigues, Isabela
    Zanardi, Piero
    Sesma, Newton
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (06) : 1397 - 1403
  • [8] Effect of different tightening protocols on the probability of survival of screw-retained implant-supported crowns
    Fardin, Vinicius P.
    Bergamo, Edmara T. P.
    Bordin, Dimorvan
    Hirata, Ronaldo
    Bonfante, Estevam A.
    Bonfante, Gerson
    Coelho, Paulo G.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 126
  • [9] Stability of Screw-Retained Implant-Supported Fixed Dental Prostheses Bonded to Gold Cylinders
    Karl, Matthias
    Graef, Friedrich
    Taylor, Thomas D.
    Heckmann, Siegfried M.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2009, 22 (06) : 604 - 606
  • [10] Torque Maintenance of Screw-Retained Implant-Supported Anterior Fixed Dental Prosthesis with Different Abutment Angulations After Aging
    Al-Zordk, Walid
    Al-Dobaisi, Tawfik
    Ghazy, Mohamed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (04) : 723 - 729