Microfluidic devices for protein analysis using intact and top-down mass spectrometry

被引:10
|
作者
Shao, Xinyang [1 ,2 ,3 ]
Huang, Yanyi [1 ,2 ,3 ,4 ,5 ]
Wang, Guanbo [1 ,2 ]
机构
[1] Shenzhen Bay Lab, Inst Cell Anal, Shenzhen, Peoples R China
[2] Peking Univ, Biomed Pioneering Innovat Ctr, Beijing, Peoples R China
[3] Peking Univ, Peking Tsinghua Ctr Life Sci, Beijing, Peoples R China
[4] Peking Univ, Coll Chem & Mol Engn, Beijing, Peoples R China
[5] Peking Univ, Beijing Natl Lab Mol Sci, Beijing, Peoples R China
关键词
mass spectrometry; microfluidic chip; native mass spectrometry; protein structures; proteomics; top-down; POROUS POLYMER MONOLITHS; SOLID-PHASE EXTRACTION; CHEMICAL CROSS-LINKING; CAPILLARY-ELECTROPHORESIS; HYDROGEN-EXCHANGE; LIQUID-CHROMATOGRAPHY; RECOMBINE MICROMIXER; PASSIVE MICROMIXER; MS DETECTION; CHIP;
D O I
10.1002/VIW.20220032
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Top-down mass spectrometry (TD-MS) provides unique information on compositions, structures, and functions of proteins or protein complexes and has been recognized as a powerful approach to complement conventional tools in protein analysis. Employing microfluidic chips in TD-MS workflows offers unique advantages including flexible integration and automation of multiple sample treatment functions, lowered sample consumption, compatibility with high-sensitive ionization and higher throughput. Here we reviewed the reported microchips developed for TD-MS in aspects of design of ionization, separation and mixing modules, and fabrication approaches; we also attempted to summarize the design considerations that may inspire development of microchips with better performance and wider applications.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Intact protein mass spectrometry and top-down proteomics
    Whitelegge, Julian
    EXPERT REVIEW OF PROTEOMICS, 2013, 10 (02) : 127 - 129
  • [2] Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
    Daniel P. Donnelly
    Catherine M. Rawlins
    Caroline J. DeHart
    Luca Fornelli
    Luis F. Schachner
    Ziqing Lin
    Jennifer L. Lippens
    Krishna C. Aluri
    Richa Sarin
    Bifan Chen
    Carter Lantz
    Wonhyeuk Jung
    Kendall R. Johnson
    Antonius Koller
    Jeremy J. Wolff
    Iain D. G. Campuzano
    Jared R. Auclair
    Alexander R. Ivanov
    Julian P. Whitelegge
    Ljiljana Paša-Tolić
    Julia Chamot-Rooke
    Paul O. Danis
    Lloyd M. Smith
    Yury O. Tsybin
    Joseph A. Loo
    Ying Ge
    Neil L. Kelleher
    Jeffrey N. Agar
    Nature Methods, 2019, 16 : 587 - 594
  • [3] Best practices and benchmarks for intact protein analysis for top-down mass spectrometry
    Donnelly, Daniel P.
    Rawlins, Catherine M.
    DeHart, Caroline J.
    Fornelli, Luca
    Schachner, Luis F.
    Lin, Ziqing
    Lippens, Jennifer L.
    Aluri, Krishna C.
    Sarin, Richa
    Chen, Bifan
    Lantz, Carter
    Jung, Wonhyeuk
    Johnson, Kendall R.
    Koller, Antonius
    Wolff, Jeremy J.
    Campuzano, Iain D. G.
    Auclair, Jared R.
    Ivanov, Alexander R.
    Whitelegge, Julian P.
    Pasa-Tolic, Ljiljana
    Chamot-Rooke, Julia
    Danis, Paul O.
    Smith, Lloyd M.
    Tsybin, Yury O.
    Loo, Joseph A.
    Ge, Ying
    Kelleher, Neil L.
    Agar, Jeffrey N.
    NATURE METHODS, 2019, 16 (07) : 587 - 594
  • [4] Top-Down and Intact Protein Mass Spectrometry Data Visualization for Proteoform Analysis Using VisioProt-MS
    Lesne, Jean
    Bousquet, Marie-Pierre
    Marcoux, Julien
    Locard-Paulet, Marie
    BIOINFORMATICS AND BIOLOGY INSIGHTS, 2019, 13
  • [5] Decoding protein modifications using top-down mass spectrometry
    Nertila Siuti
    Neil L Kelleher
    Nature Methods, 2007, 4 : 817 - 821
  • [6] Decoding protein modifications using top-down mass spectrometry
    Siuti, Nertila
    Kelleher, Neil L.
    NATURE METHODS, 2007, 4 (10) : 817 - 821
  • [7] Comprehensive Analysis of Protein Modifications by Top-Down Mass Spectrometry
    Zhang, Han
    Ge, Ying
    CIRCULATION-CARDIOVASCULAR GENETICS, 2011, 4 (06) : 711 - +
  • [8] Top-Down Analysis of Branched Proteins Using Mass Spectrometry
    Chen, Dapeng
    Gomes, Fabio
    Abeykoon, Dulith
    Lemma, Betsegaw
    Wang, Yan
    Fushman, David
    Fenselau, Catherine
    ANALYTICAL CHEMISTRY, 2018, 90 (06) : 4032 - 4038
  • [9] Top-down mass spectrometry
    Doerr A.
    Nature Methods, 2008, 5 (1) : 24 - 24
  • [10] Quantitative analysis of intact apolipoproteins in human HDL by top-down differential mass spectrometry
    Mazur, Matthew T.
    Cardasis, Helene L.
    Spellman, Daniel S.
    Liaw, Andy
    Yates, Nathan A.
    Hendrickson, Ronald C.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (17) : 7728 - 7733