Evaluation of the CNESTEN's TRIGA Mark II research reactor physical parameters with TRIPOLI-4® and MCNP

被引:0
|
作者
Ghninou, H. [1 ]
Gruel, A. [1 ]
Lyoussi, A. [1 ]
Reynard-Carette, C. [2 ]
El Younoussi, C. [3 ]
El Bakkari, B. [3 ]
Boulaich, Y. [3 ]
机构
[1] CEA, DES, IRESNE, DER,SPESI,LP2E, F-13108 St Paul Les Durance, France
[2] Univ Toulon & Var, Aix Marseille Univ, CNRS, IM2NP, Marseille, France
[3] CNESTEN, Natl Ctr Energy Sci & Nucl Technol, Rabat 10001, Morocco
关键词
MCNP simulations; TRIPOLI-4; simulations; TRIGA reactor; S/U analysis; ITERATED FISSION PROBABILITY; KINETIC-PARAMETERS; BENCHMARK ANALYSIS;
D O I
10.1016/j.net.2023.07.029
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This paper focuses on the development of a new computational model of the CNESTEN's TRIGA Mark II research reactor using the 3D continuous energy Monte-Carlo code TRIPOLI-4 (T4). This new model was developed to assess neutronic simulations and determine quantities of interest such as kinetic parameters of the reactor, control rods worth, power peaking factors and neutron flux distributions. This model is also a key tool used to accurately design new experiments in the TRIGA reactor, to analyze these experiments and to carry out sensitivity and uncertainty studies. The geometry and materials data, as part of the MCNP reference model, were used to build the T4 model. In this regard, the differences between the two models are mainly due to mathematical approaches of both codes. Indeed, the study presented in this article is divided into two parts: the first part deals with the development and the validation of the T4 model. The results obtained with the T4 model were compared to the existing MCNP reference model and to the experimental results from the Final Safety Analysis Report (FSAR). Different core configurations were investigated via simulations to test the computational model reliability in predicting the physical parameters of the reactor. As a fairly good agreement among the results was deduced, it seems reasonable to assume that the T4 model can accurately reproduce the MCNP calculated values. The second part of this study is devoted to the sensitivity and uncertainty (S/U) studies that were carried out to quantify the nuclear data uncertainty in the multiplication factor keff. For that purpose, the T4 model was used to calculate the sensitivity profiles of the keff to the nuclear data. The integrated-sensitivities were compared to the results obtained from the previous works that were carried out with MCNP and SCALE-6.2 simulation tools and differences of less than 5% were obtained for most of these quantities except for the C-graphite sensitivities. Moreover, the nuclear data uncertainties in the keff were derived using the COMAC-V2.1 covariance matrices library and the calculated sensitivities. The results have shown that the total nuclear data uncertainty in the keff is around 585 pcm using the COMAC-V2.1. This study also demonstrates that the contribution of zirconium isotopes to the nuclear data uncertainty in the keff is not negligible and should be taken into account when per-forming S/U analysis.
引用
收藏
页码:4447 / 4464
页数:18
相关论文
共 50 条
  • [1] Analysis of JS']JSI TRIGA MARK II reactor physical parameters calculated with TRIPOLI and MCNP
    Henry, R.
    Tiselj, I.
    Snoj, L.
    APPLIED RADIATION AND ISOTOPES, 2015, 97 : 140 - 148
  • [2] Numerical and experimental characterization of the reaction rates in the core of the CNESTEN's TRIGA Mark II research reactor
    Ghninou, H.
    Gruel, A.
    Lyoussi, A.
    Reynard-Carette, C.
    El Younoussi, C.
    El Bakkari, B.
    Nacir, B.
    Boulaich, Y.
    Bounouira, H.
    ANIMMA 2021 - ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS, 2021, 253
  • [3] Characterization of Neutron Reaction Rates in Different Irradiation Channels of the CNESTEN's TRIGA Mark II Research Reactor
    Ghninou, H.
    Gruel, A.
    Lyoussi, A.
    Reynard-Carette, C.
    El Younoussi, C.
    El Bakkari, B.
    Nacir, B.
    Boulaich, Y.
    Bounouira, H.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2022, 69 (07) : 1806 - 1814
  • [4] The Effect of Burnup on ITU TRIGA Mark II Research Reactor Control Parameters
    Ozkan, Fadime Ozge
    Lule, Senem Senturk
    Colak, Uner
    30TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2021), 2021,
  • [5] Effect of burnup on the neutronic parameters of ITU TRIGA Mark II research reactor
    Turkmen, Mehmet
    Colak, Uner
    Ergun, Sule
    PROGRESS IN NUCLEAR ENERGY, 2015, 83 : 26 - 34
  • [6] Neutronics analysis of TRIGA Mark II research reactor
    Rehman, Haseebur
    Ahmad, Siraj-ul-Islam
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2018, 50 (01) : 35 - 42
  • [7] Determination of neutron flux parameters in PUSPATI TRIGA Mark II Research Reactor, Malaysia
    Alnour, I. A.
    Wagiran, H.
    Ibrahim, N.
    Hamzah, S.
    Wee, B. S.
    Elias, M. S.
    Karim, J. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (03) : 1231 - 1237
  • [8] Determination of neutron flux parameters in PUSPATI TRIGA Mark II Research Reactor, Malaysia
    I. A. Alnour
    H. Wagiran
    N. Ibrahim
    S. Hamzah
    B. S. Wee
    M. S. Elias
    J. A. Karim
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 1231 - 1237
  • [10] Benchmark evaluation of reactor critical parameters and neutron fluxes distributions at zero power for the TRIGA Mark II reactor of the University of Pavia using the Monte Carlo code MCNP
    di Tigliole, A. Borio
    Cammi, A.
    Clemenza, M.
    Memoli, V.
    Pattavina, L.
    Previtali, E.
    PROGRESS IN NUCLEAR ENERGY, 2010, 52 (05) : 494 - 502