Accuracy of a Smartwatch to Assess Heart Rate Monitoring and Atrial Fibrillation in Stroke Patients

被引:3
|
作者
Meza, Claudia [1 ,2 ,3 ]
Juega, Jesus [1 ,2 ,3 ]
Francisco, Jaume [2 ,4 ]
Santos, Alba [2 ,4 ]
Duran, Laura [4 ]
Rodriguez, Maite [1 ,2 ]
Alvarez-Sabin, Jose [1 ]
Sero, Laia [5 ]
Ustrell, Xavier [5 ]
Bashir, Saima [6 ,7 ]
Serena, Joaquin [6 ,7 ]
Silva, Yolanda [6 ,7 ]
Molina, Carlos [1 ,2 ]
Pagola, Jorge [1 ,2 ,3 ]
机构
[1] Hosp Univ Vall dHebron, Dept Neurol, Stroke Unit, Barcelona 08035, Spain
[2] Vall dHebron Inst Recerca VHIR, Barcelona 08035, Spain
[3] Univ Autonoma Barcelona, Hosp Vall dHebron, Fac Med, Dept Med, Barcelona 08193, Spain
[4] Hosp Univ Vall dHebron, Dept Cardiol, Arrhythmia Unit, Barcelona 08035, Spain
[5] Hosp Univ Joan XXIII, Dept Neurol, Tarragona 43005, Spain
[6] Girona Biomed Res Inst IDIBGI, Cerebrovascular Pathol Res Grp, Girona 17790, Spain
[7] Hosp Univ Girona Dr JosepTrueta, Dept Neurol, Girona 17007, Spain
关键词
atrial fibrillation; stroke; wearable; smartwatch; screening; accuracy; WEARABLE DEVICES;
D O I
10.3390/s23104632
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
(1) Background: Consumer smartwatches may be a helpful tool to screen for atrial fibrillation (AF). However, validation studies on older stroke patients remain scarce. The aim of this pilot study from RCT NCT05565781 was to validate the resting heart rate (HR) measurement and the irregular rhythm notification (IRN) feature in stroke patients in sinus rhythm (SR) and AF. (2) Methods: Resting clinical HR measurements (every 5 min) were assessed using continuous bedside ECG monitoring (CEM) and the Fitbit Charge 5 (FC5). IRNs were gathered after at least 4 h of CEM. Lin's concordance correlation coefficient (CCC), Bland-Altman analysis, and mean absolute percentage error (MAPE) were used for agreement and accuracy assessment. (3) Results: In all, 526 individual pairs of measurements were obtained from 70 stroke patients-age 79.4 years (SD +/- 10.2), 63% females, BMI 26.3 (IQ 22.2-30.5), and NIHSS score 8 (IQR 1.5-20). The agreement between the FC5 and CEM was good (CCC 0.791) when evaluating paired HR measurements in SR. Meanwhile, the FC5 provided weak agreement (CCC 0.211) and low accuracy (MAPE 16.48%) when compared to CEM recordings in AF. Regarding the accuracy of the IRN feature, analysis found a low sensitivity (34%) and high specificity (100%) for detecting AF. (4) Conclusion: The FC5 was accurate at assessing the HR during SR, but the accuracy during AF was poor. In contrast, the IRN feature was acceptable for guiding decisions regarding AF screening in stroke patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Provider Perspectives on Smartwatch Monitoring for Atrial Fibrillation
    Ding, Eric Y.
    Dickson, Emily
    Albuquerque, Daniella
    Saczynski, Jane S.
    Chon, Ki
    McManus, David D.
    CIRCULATION, 2019, 140
  • [2] Heart rate variability and stroke or systemic embolism in patients with atrial fibrillation
    Hammerle, Peter
    Aeschbacher, Stefanie
    Schlageter, Vincent
    Coslovsky, Michael
    Hennings, Elisa
    Krisai, Philipp
    Coduri, Federica
    Blum, Manuel R.
    Rodondi, Nicolas
    Reichlin, Tobias
    Muller, Andreas
    Stauber, Annina
    Moschovitis, Giorgio
    Rigamonti, Elia
    Beer, Jurg
    Ammann, Peter
    Bonati, Leo H.
    Conen, David
    Osswald, Stefan
    Kuhne, Michael
    Zuern, Christine S.
    HEART RHYTHM, 2024, 21 (09) : 1509 - 1516
  • [3] Accuracy of heart rate obtained by auscultation in atrial fibrillation
    Glaus, TM
    Hässig, M
    Keene, BW
    JOURNAL OF THE AMERICAN ANIMAL HOSPITAL ASSOCIATION, 2003, 39 (03) : 237 - 239
  • [4] Accuracy of the Apple Watch 4 to Measure Heart Rate in Patients With Atrial Fibrillation
    Seshadri, Dhruv R.
    Bittel, Barb
    Browsky, Dalton
    Houghtaling, Penny
    Drummond, Colin K.
    Desai, Milind
    Gillinov, A. Marc
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2020, 8
  • [5] Accuracy and reliability of wristband smartwatch-based estimation of circadian rhythm of heart rate in stroke patients
    Yao, Lin
    Pan, Xi
    Yang, Yiqun
    Zhong, Weiying
    Li, Jiaxuan
    Wang, Zhi
    Xu, Lan
    NEUROLOGY ASIA, 2024, 29 (01) : 61 - 69
  • [6] ACCURACY OF HEART-RATE ASSESSMENT IN ATRIAL-FIBRILLATION
    SNEED, NV
    HOLLERBACH, AD
    HEART & LUNG, 1992, 21 (05): : 427 - 433
  • [7] Predictors for Heart Rate in Patients With Atrial Fibrillation
    Moschovitis, Giorgio
    Blum, Steffen
    Pfister, Otmar
    Ammann, Peter
    Erne, Paul
    di Valentino, Marcello
    Shah, Dipen
    Schlapfer, Jurg
    Kuhne, Michael
    Sticherling, Christian
    Osswald, Stefan
    Conen, David
    CIRCULATION, 2017, 136
  • [8] Scattering Transform of Heart Rate Variability for the Prediction of Ischemic Stroke in Patients with Atrial Fibrillation
    Leonarduzzi, Roberto
    Abry, Patrice
    Wendt, Herwig
    Kiyono, Ken
    Yamamoto, Yoshiharu
    Watanabe, Eiichi
    Hayano, Junichiro
    METHODS OF INFORMATION IN MEDICINE, 2018, 57 (03) : 141 - 145
  • [9] Continuous heart rate monitoring in atrial fibrillation with multispectral photoplethysmography
    Devaki, V.
    Lakshmanan, Madan Kumar
    Aravindan, R.
    Dhandapani, V. E.
    Jayanthi, T.
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 380
  • [10] Optimization of the Heart Rate Control in Atrial Fibrillation by Monitoring of the Digoxin Concentration in Elderly Patients
    Zadvorev, Sergei F.
    Yakovlev, Artem A.
    Pushkin, Aleksandr S.
    Rukavishnikova, Svetlana A.
    Filippov, Aleksandr E.
    Obrezan, Andrey G.
    RATIONAL PHARMACOTHERAPY IN CARDIOLOGY, 2018, 14 (03) : 330 - 336