Racial and ethnic disparities amongst patients with lay rescuer automated external defibrillator placement after out-of-hospital cardiac arrest

被引:4
|
作者
Toy, Jake [1 ,2 ,3 ,4 ,5 ]
机构
[1] Los Angeles Cty EMS Agcy, 10100 Pioneer Blvd, Suite 200, Santa Fe Springs, CA 90670 USA
[2] Univ Calif Los Angeles, Fielding Sch Publ Hlth, 650 Charles Young Dr S, Los Angeles, CA 90095 USA
[3] Angeles Cty EMS Agcy, 10100 Pioneer Blvd, Santa Fe Springs, CA 90670 USA
[4] Harbor UCLA Med Ctr, Dept Emergency Med, 1000 W Carson St, Torrance, CA 90502 USA
[5] Lundquist Inst, 1000 W Carson St, Torrance, CA 90502 USA
关键词
Out-of-hospital cardiac arrest; Automated external defibrillator; Public-access automated external defibrillator; LOCATION; OUTCOMES;
D O I
10.1016/j.resuscitation.2023.109902
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: This study evaluated the association between patient race/ethnicity and the odds of AED provision by a lay rescuer in out-of-hospital cardiac arrest (OHCA) in the United States.Methods: This was a cross-sectional retrospective study of OHCA patients in the National Emergency Medical Services Information System data-base from the year 2021. Patients were excluded for age < 18 years, EMS-witnessed arrest, traumatic arrest, arrest in a healthcare setting, do-not-resuscitate order, and arrest in a wilderness location. The primary outcome was the association between race/ethnicity and the odds of lay-rescuer AED placement for OHCA. Multiple logistic regression adjusting for known covariates was performed and odds ratios were reported.Results: A total of 207,134 patients were included. Patients with lay rescuer AED use had statistically significant differences with regard to arrest location and arrest witnessed status, and had longer EMS response times (8.5 minutes vs 7 minutes). The odds of AED use was lowest for American Indian/Alaskan Native persons (OR 0.62; 95% CI 0.54, 0.72) followed by Asian (OR 0.66; 95% CI 0.60, 0.72), Hispanic (OR 0.66; 95% CI 0.63, 0.69) and Native Hawaiian/Pacific Islander patients (OR 0.69; 95% CI 0.57, 0.83) when compared to White patients. Black patients had the highest odds of AED use (OR 1.10; 95% CI 1.07, 1.12).Conclusion: When compared to White persons, the odds of lay rescuer AED use in OHCA was between 31-38% lower for American Indian/Alas-kan Native, Asian, Hispanic, and Native Hawaiian/Pacific Islander persons, and 10% higher for Black persons.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Persistent Racial/Ethnic Disparities in Out-of-Hospital Cardiac Arrest
    Shekhar, Aditya C.
    Mercer, Christopher
    Ball, Robert
    Blumen, Ira
    ANNALS OF EMERGENCY MEDICINE, 2021, 78 (02) : 314 - 316
  • [2] Age and Racial/Ethnic Disparities in Pediatric Out-of-Hospital Cardiac Arrest
    Shekhar, Aditya C.
    Campbell, Teri
    Mann, N. Clay
    Blumen, Ira J.
    Madhok, Manu
    CIRCULATION, 2022, 145 (16) : 1288 - 1289
  • [3] Automated External Defibrillator Use After Out-of-Hospital Cardiac Arrest at Recreational Facilities
    Kolkailah, Ahmed A.
    Chan, Paul S.
    Li, Qiang
    Uzendu, Anezi
    Khan, Mirza S.
    Girotra, Saket
    JAMA INTERNAL MEDICINE, 2024, 184 (02) : 218 - 220
  • [4] Automated external defibrillator and operator performance in out-of-hospital cardiac arrest
    Zijlstra, Jolande A.
    Bekkers, Loes E.
    Hulleman, Michiel
    Beesems, Stefanie G.
    Koster, Rudolph W.
    RESUSCITATION, 2017, 118 : 140 - 146
  • [5] A Poor Association Between Out-of-Hospital Cardiac Arrest Location and Public Automated External Defibrillator Placement
    Levy, Matthew J.
    Seaman, Kevin G.
    Millin, Michael G.
    Bissell, Richard A.
    Jenkins, J. Lee
    PREHOSPITAL AND DISASTER MEDICINE, 2013, 28 (04) : 342 - 347
  • [6] Accuracy of Automated External Defibrillator Pad Placement During Out-of-Hospital Cardiac Arrest Resuscitation Simulations
    Missel, Amanda L.
    Rizk, Daniel
    Dowker, Stephen R.
    Scott, Isabella G.
    Majhail, Noor K.
    Hunt, Nathaniel
    Neumar, Robert W.
    CIRCULATION, 2023, 148
  • [7] Accuracy of Automated External Defibrillator Pad Placement During Out-of-Hospital Cardiac Arrest Resuscitation Simulations
    Missel, Amanda L.
    Gomez, Alejandro
    Dowker, Stephen R.
    Rizk, Daniel
    Neumar, Robert W.
    Hunt, Nathaniel
    PREHOSPITAL EMERGENCY CARE, 2024,
  • [8] Failure of cardiac rhythm analysis by automated external defibrillator in an out-of-hospital cardiac arrest
    Cmorej, P. Ch.
    Smrzova, E.
    Mach, J.
    ANESTEZIOLOGIE A INTENZIVNI MEDICINA, 2018, 29 (03): : 135 - 138
  • [9] Racial disparities in out-of-hospital cardiac arrest in Denmark
    Garcia, R.
    Rajan, D.
    Barcella, C. A.
    Svane, J.
    Warming, P. E.
    Jabbari, R.
    Gislason, G. H.
    Torp-Petersen, C.
    Folke, F.
    Tfelt-Hansen, J.
    EUROPEAN HEART JOURNAL, 2021, 42 : 647 - 647
  • [10] Impact of Receiving Hospital on Out-of-Hospital Cardiac Arrest Outcome: Racial and Ethnic Disparities in Texas
    Huebinger, Ryan
    Del Rios, Marina
    Abella, Benjamin S.
    McNally, Bryan
    Bakunas, Carrie
    Witkov, Richard
    Panczyk, Micah
    Boerwinkle, Eric
    Bobrow, Bentley
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2023, 12 (21):