Dosimetry impact of distinct gating strategies in cine MR image-guided breath-hold pancreatic cancer radiotherapy

被引:1
|
作者
Dong, Yuyan [1 ]
Hu, Panpan [1 ,2 ]
Li, Xiaoyang [1 ,2 ]
Liu, Wei [2 ]
Yan, Bing [2 ]
Yang, Fei [3 ]
Ford, John Chetley [3 ]
Portelance, Lorraine [3 ]
Yang, Yidong [1 ,2 ]
机构
[1] Univ Sci & Technol China, Dept Engn & Appl Phys, Hefei, Anhui, Peoples R China
[2] Univ Sci & Technol China, Affiliated Hosp USTC 1, Dept Radiat Oncol, Div Life Sci & Med, Hefei 230026, Anhui, Peoples R China
[3] Univ Miami, Miller Sch Med, Miami, FL USA
来源
关键词
breath hold; cine MRI; gating strategies; pancreatic cancer; TIME TUMOR-TRACKING; BODY RADIATION-THERAPY; LUNG-CANCER; RESPIRATORY MOTION; SYSTEM; MANAGEMENT; PHANTOM; LIVER; VMAT;
D O I
10.1002/acm2.14078
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo investigate the dosimetry effects of different gating strategies in cine magnetic resonance imaging (MRI)-guided breath-hold pancreatic cancer radiotherapy. MethodsTwo cine MRI-based gating strategies were investigated: a tumor contour-based gating strategy at a gating threshold of 0-5% and a tumor displacement-based gating strategy at a gating threshold of 3-5 mm. The cine MRI videos were obtained from 17 pancreatic cancer patients who received MRI-guided radiation therapy. We calculated the tumor displacement in each cine MR frame that satisfied the gating threshold and obtained the proportion of frames with different displacements. We generated IMRT and VMAT plans using a 33 Gy prescription, and motion plans were generated by adding up all isocenter-shift plans corresponding to different tumor displacements. The dose parameters of GTV, PTV, and organs at risk (OAR) were compared between the original and motion plans. ResultsIn both gating strategies, the difference was significant in PTV coverage but not in GTV coverage between the original and motion plans. OAR dose parameters deteriorate with increasing gating threshold. The beam duty cycle increased from 19.5 +/- 14.3% (median 18.0%) to 60.8 +/- 15.6% (61.1%) for gating thresholds from 0% to 5% in tumor contour-based gating and from 51.7 +/- 11.5% (49.7%) to 67.3 +/- 12.4% (67.1%) for gating thresholds from 3 to 5 mm in tumor displacement-based gating. ConclusionIn tumor contour-based gating strategy, the dose delivery accuracy deteriorates while the dose delivery efficiency improves with increasing gating thresholds. To ensure treatment efficiency, the gating threshold might be no less than 3%. A threshold up to 5% may be acceptable in terms of the GTV coverage. The displacement-based gating strategy may serve as a potential alternative to the tumor contour based gating strategy, in which the gating threshold of approximately 4 mm might be a good choice for reasonably balancing the dose delivery accuracy and efficiency.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Dosimetry Impact of Gating Threshold Selection in Cine-MR Image Guided Breath-Hold Pancreatic Cancer Radiotherapy
    Dong, Y.
    Hu, P.
    Yang, F.
    Yang, Y.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Dosimetry impact of gating latency in cine magnetic resonance image guided breath-hold pancreatic cancer radiotherapy
    Hu, Panpan
    Li, Xiaoyang
    Liu, Wei
    Yan, Bing
    Xue, Xudong
    Yang, Fei
    Ford, John Chetley
    Portelance, Lorraine
    Yang, Yidong
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (05):
  • [3] Dosimetry Impact of Cine Magnetic Resonance Image Gating in Breath Hold Pancreatic Cancer Radiotherapy
    Hu, P.
    Yang, F.
    Yang, Y.
    MEDICAL PHYSICS, 2020, 47 (06) : E500 - E500
  • [4] The Impact of Cine Magnetic Resonance Image Gating in Breath Hold Pancreas Cancer Radiotherapy
    Yang, Y.
    Portelance, L.
    Dogan, N.
    Pollack, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E205 - E205
  • [5] Hypofractionated image-guided breath-hold radiotherapy of liver metastases - clinical results
    Boda-Heggemann, J.
    Dinter, D.
    Weiss, C.
    Siebenlist, K.
    Attenberger, U.
    Frauenfeld, A.
    Ottstadt, M.
    Simeonova, A.
    Schneider, F.
    Hofheinz, R.
    Lohr, F.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 : 19 - 19
  • [6] Inter-breath-hold motion in gated cone-beam CT introducing uncertainties in image-guided radiotherapy for breath-hold treatment
    Zhuang, Tingliang
    Magnelli, Anthony
    Liu, Han
    Qi, Peng
    Djemil, Toufik
    Stephans, Kevin
    Videtic, Gregory
    Xia, Ping
    JOURNAL OF RADIATION ONCOLOGY, 2014, 3 (03) : 321 - 330
  • [7] Breath-hold cardiac MR imaging: Improvements in image quality with fast SE, TurboSTIR, HASTE, and breath-hold cine MR angiography compared with standard techniques
    Hartnell, GG
    Charlamb, M
    Cohen, MC
    Saouaf, R
    Simonetti, OP
    Finn, JP
    RADIOLOGY, 1996, 201 : 788 - 788
  • [8] Evaluation of image-guided and surface-guided radiotherapy for breast cancer patients treated in deep inspiration breath-hold: A single institution experience
    Penninkhof, Joan
    Fremeijer, Kimm
    Harten, Kirsten Offereins-van
    van Wanrooij, Cynthia
    Quint, Sandra
    Kunnen, Britt
    Hoffmans-Holtzer, Nienke
    Swaak, Annemarie
    Baaijens, Margreet
    Dirkx, Maarten
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2022, 21 : 51 - 57
  • [9] Hypofractionated image-guided breath-hold SABR (Stereotactic Ablative Body Radiotherapy) of liver metastases - clinical results
    Boda-Heggemann, Judit
    Dinter, Dietmar
    Weiss, Christel
    Frauenfeld, Anian
    Siebenlist, Kerstin
    Attenberger, Ulrike
    Ottstadt, Martine
    Schneider, Frank
    Hofheinz, Ralf-Dieter
    Wenz, Frederik
    Lohr, Frank
    RADIATION ONCOLOGY, 2012, 7
  • [10] Prospective phase II trial of image-guided radiotherapy in Hodgkin lymphoma: Benefit of deep inspiration breath-hold
    Petersen, Peter M.
    Aznar, Marianne C.
    Berthelsen, Anne K.
    Loft, Annika
    Schut, Deborah A.
    Maraldo, Maja
    Josipovic, Mirjana
    Klausen, Thomas L.
    Andersen, Flemming L.
    Specht, Lena
    ACTA ONCOLOGICA, 2015, 54 (01) : 60 - 66