Adjustable transobturator male system (ATOMS) for stress urinary incontinence: the evidence is mounting

被引:3
|
作者
Bajaj, Mohit [1 ,4 ]
Frampton, Chris [2 ]
Losco, Giovanni [3 ]
Westenberg, Andre [1 ]
机构
[1] Tauranga Hosp, Tauranga, New Zealand
[2] Univ Otago, Stat Dept, Dunedin, New Zealand
[3] Christchurch Hosp, Christchurch, New Zealand
[4] 57 Killeen St, Nundah, Qld 4012, Australia
关键词
adjustable transobturator male system continence device (ATOMS); incontinence; male stress urinary incontinence; post prostatectomy incontinence; efficacy; EXPERIENCE; SPHINCTER; OUTCOMES;
D O I
10.1111/bju.16118
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives To evaluate the New Zealand clinical experience with the adjustable transobturator male system (ATOMS), a novel continence device in the management of all degrees of stress urinary incontinence (SUI), focusing on efficacy and safety outcomes. Patients and Methods A retrospective review of all ATOMS devices placed between May 2015 and November 2020 was conducted. Severity of SUI was assessed (pad usage) before and after surgery. SUI was defined as mild (1-<3 pads/day), moderate (>= 3-5 pads/day) or severe (>5 pads/day). The primary outcome measures considered were the overall success rate (improvement in pad use) and the dry rate (with dry defined as either no or 1 safety pad/day). The number of outpatient adjustments and total filling volumes were also documented in each case. Additionally, we documented incidence and severity of device complications and an analysis of treatment failures. Results A total of 140 patients were reviewed, with the most common indication for ATOMS placement being SUI after radical prostatectomy (82.8%). Of the patients included, 53 (37.9%) had previous radiotherapy, with 26 (18.6%) patients having had a previous continence procedure performed. No intraoperative complications were noted. The median preoperative pad usage was 4 pads/day. After a median follow-up of 11 months, median postoperative pad usage reduced to 1 pad/day. In our cohort, 116 patients (82.9%) reported an improvement in their pad usage and were considered successful with 107 (76.4%) patients reporting themselves to be dry. Complications within the first 90-days after surgery occurred in 20 (14.3%) of patients. Conclusion Treatment of SUI with the ATOMS is safe and effective. The option of long-term, minimally invasive adjustment to respond to patient needs is a significant advantage.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 50 条
  • [1] Current status of the adjustable transobturator male system (ATOMS™) for male stress urinary incontinence
    Juliebo-Jones, Patrick
    Roth, Ingunn
    Tzelves, Lazaros
    Hjelle, Karin M.
    Moen, Christian Arvei
    Esperto, Francesco
    Somani, Bhaskar K.
    Beisland, Christian
    FRONTIERS IN SURGERY, 2024, 11
  • [2] Adjustable transobturator male system (ATOMS®) as treatment of stress urinary incontinence secondary to transurethral resection of the prostate
    Angulo, J. C.
    Fonseca, J.
    Esquinas, C.
    Ojea, A.
    Rodriguez, A.
    Rabassa, M.
    Teba, F.
    Escribano, G.
    Cruz, F.
    ACTAS UROLOGICAS ESPANOLAS, 2018, 42 (09): : 567 - 573
  • [3] Adjustable Transobturator Male System® (ATOMS) as a novel treatment for men with stress urinary incontinence in the United Kingdom
    Yang, Bob
    Lewis, Francesca
    Jelley, Clare
    Foley, Steve
    JOURNAL OF CLINICAL UROLOGY, 2024, 17 (04) : 363 - 370
  • [4] Adjustable male sling (ATOMS® System) for male stress urinary incontinence
    Pun, C. T.
    Cheng, C. H.
    Li, M. L.
    Chu, S. K.
    Man, C. W.
    BJU INTERNATIONAL, 2017, 119 : 15 - 15
  • [5] 5-YEAR EXPERIENCE ON THE ADJUSTABLE TRANSOBTURATOR MALE SYSTEM (ATOMS®) IN UK MEN WITH STRESS URINARY INCONTINENCE
    Yang, Bob
    Kowalski, Piotr
    Jelley, Claire
    Foley, Steve
    JOURNAL OF UROLOGY, 2020, 203 : E593 - E593
  • [6] Treatment of stress urinary incontinence after prostatectomy with the adjustable transobturator male system (ATOMS®) with preattached scrotal port
    Esquinas, C.
    Arance, I.
    Pamplona, J.
    Moraga, A.
    Dorado, J. F.
    Angulo, J. C.
    ACTAS UROLOGICAS ESPANOLAS, 2018, 42 (07): : 473 - 482
  • [7] The Adjustable Transobturator Male System in Stress Urinary Incontinence After Transurethral Resection of the Prostate
    Friedl, Alexander
    Schneeweiss, Jenifer
    Stangl, Kathrin
    Muehlstaedt, Sandra
    Zachoval, Roman
    Hruby, Stephan
    Gruendler, Therese
    Kivaranovic, Danijel
    Fornara, Paolo
    Lusuardi, Lukas
    Broessner, Clemens
    UROLOGY, 2017, 109 : 184 - 189
  • [8] Outcomes with the Adjustable Transobturator Male System (ATOMS) for the Treatment of Male Stress Urinary Incontinence After Prostate Surgery and the Impact of Previous Radiotherapy
    Roth, Ingunn
    Juliebo-Jones, Patrick
    Moen, Christian Arvei
    Beisland, Christian
    Hjelle, Karin M.
    EUROPEAN UROLOGY OPEN SCIENCE, 2024, 62 : 68 - 73
  • [9] Outcomes with the Adjustable Transobturator Male System (ATOMS) for the Treatment of Male Stress Urinary Incontinence After Prostate Surgery and the Impact of Previous Radiotherapy
    Roth, Ingunn
    Juliebo-Jones, Patrick
    Moen, Christian Arvei
    Beisland, Christian
    Hjelle, Karin M.
    EUROPEAN UROLOGY OPEN SCIENCE, 2024, 62 : 68 - 73
  • [10] ADJUSTABLE TRANSOBTURATOR MALE SYSTEM (ATOMS®) - A NOVEL TREATMENT OPTION IN MEN WITH STRESS URINARY INCONTINENCE: THE FIRST EXPERIENCE IN THE UNITED KINGDOM
    Yang, Bob
    Jelley, Clare
    Foley, Steve
    JOURNAL OF UROLOGY, 2019, 201 (04): : E662 - E662