Comparison of the Diagnostic Accuracies of Monocyte Distribution Width, Procalcitonin, and C-Reactive Protein for Sepsis: A Systematic Review and Meta-Analysis

被引:21
|
作者
Huang, Yu-Hsuan [1 ]
Chen, Ching-Jung [2 ]
Shao, Shih-Chieh [3 ]
Li, Chih-Huang [1 ,4 ]
Hsiao, Chien-Han [5 ]
Niu, Kuang-Yu [6 ]
Yen, Chieh-Ching [1 ,7 ,8 ]
机构
[1] Chang Gung Mem Hosp, Dept Emergency Med, Linkou Branch, Taoyuan, Taiwan
[2] Chang Gung Mem Hosp, Dept Internal Med, Linkou Branch, Taoyuan, Taiwan
[3] Keelung Chang Gung Mem Hosp, Dept Pharm, Keelung, Taiwan
[4] Chang Gung Univ, Grad Inst Clin Med Sci, Taoyuan, Taiwan
[5] Indiana Univ, Dept Linguist, Bloomington, IN USA
[6] Keelung Chang Gung Mem Hosp, Dept Emergency Med, Keelung, Taiwan
[7] New Taipei Municipal Tucheng Hosp, Dept Emergency Med, New Taipei, Taiwan
[8] Jen Ai Hosp, Dept Emergency Med, Dali Branch, Taichung, Taiwan
关键词
biomarker; meta-analysis; monocyte distribution width; sepsis; EMERGENCY-DEPARTMENT; PROGNOSTIC ACCURACY; SUSPECTED INFECTION; ORGAN FAILURE; PREDICTION; MDW; TOOL; DEFINITIONS; PERFORMANCE; GUIDELINES;
D O I
10.1097/CCM.0000000000005820
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
OBJECTIVES: We performed a systemic review and meta-analysis to evaluate the diagnostic accuracy of monocyte distribution width (MDW) and to compare with procalcitonin and C-reactive protein (CRP), in adult patients with sepsis. DATA SOURCES: A systematic literature search was performed in PubMed, Embase, and the Cochrane Library to identify all relevant diagnostic accuracy studies published before October 1, 2022. STUDY SELECTION: Original articles reporting the diagnostic accuracy of MDW for sepsis detection with the Sepsis-2 or Sepsis-3 criteria were included. DATA EXTRACTION: Study data were abstracted by two independent reviewers using a standardized data extraction form. DATA SYNTHESIS: Eighteen studies were included in the meta-analysis. The pooled sensitivity and specificity of MDW were 84% (95% CI [79-88%]) and 68% (95% CI [60-75%]). The estimated diagnostic odds ratio and the area under the summary receiver operating characteristic curve (SROC) were 11.11 (95% CI [7.36-16.77]) and 0.85 (95% CI [0.81-0.89]). Significant heterogeneity was observed among the included studies. Eight studies compared the diagnostic accuracies of MDW and procalcitonin, and five studies compared the diagnostic accuracies of MDW and CRP. For MDW versus procalcitonin, the area under the SROC was similar (0.88, CI = 0.84-0.93 vs 0.82, CI = 0.76-0.88). For MDW versus CRP, the area under the SROC was similar (0.88, CI = 0.83-0.93 vs 0.86, CI = 0.78-0.95). CONCLUSIONS: The results of the meta-analysis indicate that MDW is a reliable diagnostic biomarker for sepsis as procalcitonin and CRP. Further studies investigating the combination of MDW and other biomarkers are advisable to increase the accuracy in sepsis detection.
引用
收藏
页码:E106 / E114
页数:9
相关论文
共 50 条
  • [1] The diagnostic accuracy of procalcitonin and C-reactive protein for sepsis: A systematic review and meta-analysis
    Tan, Meichun
    Lu, Yunxia
    Jiang, Hao
    Zhang, Liandong
    JOURNAL OF CELLULAR BIOCHEMISTRY, 2019, 120 (04) : 5852 - 5859
  • [2] Comparison of diagnostic accuracy in sepsis between presepsin, procalcitonin, and C-reactive protein: a systematic review and meta-analysis
    Wu, Chin-Chieh
    Lan, Hao-Min
    Han, Shih-Tsung
    Chaou, Chung-Hsien
    Yeh, Chun-Fu
    Liu, Su-Hsun
    Li, Chih-Huang
    Blaney, Gerald N., III
    Liu, Zhen-Ying
    Chen, Kuan-Fu
    ANNALS OF INTENSIVE CARE, 2017, 7
  • [3] Comparison of diagnostic accuracy in sepsis between presepsin, procalcitonin, and C-reactive protein: a systematic review and meta-analysis
    Chin-Chieh Wu
    Hao-Min Lan
    Shih-Tsung Han
    Chung-Hsien Chaou
    Chun-Fu Yeh
    Su-Hsun Liu
    Chih-Huang Li
    Gerald N. Blaney
    Zhen-Ying Liu
    Kuan-Fu Chen
    Annals of Intensive Care, 7
  • [4] Monocyte Distribution Width, a Novel Biomarker for Early Sepsis Screening and Comparison with Procalcitonin and C-Reactive Protein
    Meraj, Fatima
    Shaikh, Sumera
    Maqsood, Sidra
    Kanani, Fatima
    Khan, Hamza
    Jamal, Saba
    JOURNAL OF LABORATORY PHYSICIANS, 2023, 15 (02) : 294 - 299
  • [5] Comparison of monocyte distribution width and Procalcitonin as diagnostic markers for sepsis: Meta-analysis of diagnostic test accuracy studies
    Motawea, Karam
    Rozan, Samah S.
    Talat, Nesreen Elsayed
    Elhalag, Rowan H.
    Reyad, Sarraa Mohammed
    Chebl, Pensee
    Swed, Sarya
    Sawaf, Bisher
    Alfar, Hadeel Hadeel
    Farwati, Amr
    Sabbagh, Bana
    Madera, Esperance M.
    El Metaafy, Amro
    Barboza, Joshuan J.
    Sah, Ranjit
    Aiash, Hani
    PLOS ONE, 2023, 18 (08):
  • [6] Diagnostic Performance of Monocyte Distribution Width for the Detection of Sepsis: A Systematic Review and Meta-Analysis
    Eisinger, Gregory J.
    Hosler, Quinn
    Crouser, Elliott D.
    Herman, Derrick D.
    JOURNAL OF THE AMERICAN COLLEGE OF EMERGENCY PHYSICIANS OPEN, 2025, 6 (02)
  • [7] Comparison of the accuracy of neutrophil CD64, procalcitonin, and C-reactive protein for sepsis identification: a systematic review and meta-analysis
    Yeh, Chun-Fu
    Wu, Chin-Chieh
    Liu, Su-Hsun
    Chen, Kuan-Fu
    ANNALS OF INTENSIVE CARE, 2019, 9 (1)
  • [8] Comparison of the accuracy of neutrophil CD64, procalcitonin, and C-reactive protein for sepsis identification: a systematic review and meta-analysis
    Chun-Fu Yeh
    Chin-Chieh Wu
    Su-Hsun Liu
    Kuan-Fu Chen
    Annals of Intensive Care, 9
  • [9] Monocyte distribution width compared with C-reactive protein and procalcitonin for early sepsis detection in the emergency department
    la Woo, A.
    Oh, Dong Kyu
    Park, Chan-Jeoung
    Hong, Sang-Bum
    PLOS ONE, 2021, 16 (04):
  • [10] Diagnostic accuracies of procalcitonin and C-reactive protein for bacterial infection in patients with systemic rheumatic diseases: a meta-analysis
    Song, G. G.
    Bae, S. -C.
    Lee, Y. H.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2015, 33 (02) : 166 - 173