Validation of Monte Carlo simulated absorbed-dose-to-water inside a custom SPECT/CT phantom using active and passive dosimeters: a feasibility study using 99mTc

被引:2
|
作者
Bertinetti, Andrew [1 ]
Rodrigues, Miesher [2 ]
Palmer, Benjamin [1 ]
Garcia, Timothy R. [2 ]
Vija, A. Hans [2 ]
Culberson, Wesley [1 ]
机构
[1] Univ Wisconsin Madison, Madison, WI 53706 USA
[2] Siemens Healthineers, Malvern, PA USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 08期
关键词
targeted radionuclide therapy; radiopharmaceutical therapy; SPECT; CT; Monte Carlo; phantom; absorbed dose to water; active; passive dosimetry; TARGETED RADIONUCLIDE THERAPY; PHOTON; DETECTOR;
D O I
10.1088/1361-6560/acc635
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective.This project aims to provide a novel method for performing dosimetry measurements on TRT radionuclides using a custom-made SPECT/CT compatible phantom, common active and passive detectors, and Monte Carlo simulations. In this work we present a feasibility study using Tc-99m for a novel approach to obtaining reproducible measurements of absorbed-dose-to-water from radionuclide solutions using active and passive detectors in a custom phantom for the purpose of benchmarking Monte Carlo-based absorbed-dose-to-water estimates. Approach. A cylindrical, acrylic SPECT/CT compatible phantom capable of housing an IBA EFD diode, SNC600c Farmer type ion chamber, and TLD-100 microcubes was designed and built for the purpose of assessing internal absorbed-dose-to-water at various points within a solution of Tc-99m. The phantom is equipped with removable inserts that allow for numerous detector configurations and is designed to be used for verification of SPECT/CT-based absorbed-dose estimates with traceable detector measurements at multiple locations. Three experiments were conducted with exposure times ranging from 11 to 21 h with starting activities of approximately 10-16 GBq. Measurement data was compared to Monte Carlo simulations using the egs_chamber user code in EGSnrc 2019. Main results. In general, the ionization chamber measurements agreed with the Monte Carlo simulations within k = 1 uncertainty values (+/- 4% and +/- 7%, respectively). Measurements from the TLDs yielded results within k = 1 agreement of the MC prediction (+/- 6% and +/- 5%, respectively). Agreement within k = 1 uncertainty (+/- 6% and +/- 7%, respectively) was obtained for the diode for one of three conducted experiments. Significance. While relatively large uncertainties remain, the agreement between measured and simulated absorbed-doses provides proof of principal that dosimetry of radionuclide solutions with active detectors may be performed using this type of phantom with potential modifications for beta-emitting radionuclides to be introduced in future work.
引用
收藏
页数:15
相关论文
共 4 条
  • [1] Validation of Monte Carlo Simulated Tc-99m Absorbed-Dose-To-Water Inside a Custom SPECT/CT Phantom Using Active and Passive Dosimeters: A Novel Approach to Benchmarking Monte Carlo Methods for Targeted Radionuclide Therapy Dosimetry
    Bertinetti, A.
    Rodrigues, M.
    Palmer, B.
    Hammer, C.
    Hull, J.
    Vija, H.
    Culberson, W.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Quantification in simultaneous 99mTc/123I brain SPECT using generalized spectral factor analysis:: a Monte Carlo study
    Hapdey, Sebastien
    Soret, Marine
    Buvat, Irene
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (23): : 6157 - 6171
  • [3] Monte Carlo-based estimation of patient absorbed dose in 99mTc-DMSA,-MAG3, and -DTPA SPECT imaging using the University of Florida (UF) phantoms
    Khoshyari, Zeynab
    Jahangir, Reza
    Miri-Hakimabad, Hashem
    Mohammadi, Najmeh
    Arabi, Hossein
    APPLIED RADIATION AND ISOTOPES, 2025, 220
  • [4] Using adaptive neuro-fuzzy inference system technique for crosstalk correction in simultaneous 99mTc/201Tl SPECT imaging: A Monte Carlo simulation study
    Heidary, Saeed
    Setayeshi, Saeed
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 770 : 14 - 20