Solidification Analysis, Microhardness, and Corrosion Resistance of a Cast Hip Prosthesis in ASTM F745 Austenitic Stainless Steel

被引:1
|
作者
Kociubczyk, Alex, I [1 ]
Grau, Jorge E. [2 ]
Sarutti, Jose L. [2 ]
Mendez, Claudia M. [1 ]
Gregorutti, Ricardo W. [2 ]
Ares, Alicia E. [1 ]
机构
[1] IMAM CONICET UNaM, Mat Inst Misiones, Inst Mat Misiones, 1552 Felix de Azara St,N3300LQD, Posadas, Misiones, Argentina
[2] LEMIT CICPBA, Lab Entrenamiento Multidisciplinario La Invest Te, Multidisciplinary Training Lab Technol Res, Av 52 W-n 121 & 122,B1900AYB, La Plata, Buenos Aires, Argentina
关键词
cooling curves; corrosion behavior; hip prosthesis; microhardness; microstructure; solidification; MECHANICAL-PROPERTIES; ZN-AL; BEHAVIOR; MICROSTRUCTURE; MEDIA; PH;
D O I
10.1007/s11665-022-07164-x
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The solidification of a hip prosthesis has been studied using cooling curves in two differentiated regions: the area near the acetabulum that presents a greater mass and the distal stem area which is the thinnest area of the prosthesis. The differential thermal analysis has shown that the cooling rate, the undercooling and the thermal gradient in the distal stem have been higher due to a higher caloric extraction recorded in this area. As a consequence, a thinner dendritic structure has been obtained, with smaller primary and secondary dendritic spacings. At the same time, it has been observed that the microsegregation of the Cr and Mo elements has been lower in the distal stem. Furthermore, there is a correlation between secondary dendritic spacing and microhardness, which has shown that the dendritic spacing increases, as the microhardness increases. Additionally, corrosion resistance has been evaluated in those regions by means of the cyclic polarization test and electrochemical impedance spectroscopy (EIS). The analyses have been carried out at pH between 5 and 9, and at 37 C and 42 degrees C. The results have shown that the susceptibility to localized corrosion decreased with increasing pH in the evaluated range. The impedance results indicated that hip prosthesis behaves better at 37 degrees C and pH 7, and if this condition is broken, due to an increase of temperature or change of pH, the area near the acetabulum presents lower resistance corrosion.
引用
收藏
页码:1065 / 1075
页数:11
相关论文
共 12 条
  • [1] Solidification Analysis, Microhardness, and Corrosion Resistance of a Cast Hip Prosthesis in ASTM F745 Austenitic Stainless Steel
    Alex I. Kociubczyk
    Jorge E. Grau
    José L. Sarutti
    Claudia M. Méndez
    Ricardo W. Gregorutti
    Alicia E. Ares
    Journal of Materials Engineering and Performance, 2023, 32 : 1065 - 1075
  • [2] Research on the Corrosion Resistance of Cast Austenitic Stainless Steel Reinforced by Modified SiC Nanopowders
    Yang Jun
    Gao Hong
    Chen Meiling
    Liu Yuandong
    Xu Yu
    CHEMISTRY FOR SUSTAINABLE DEVELOPMENT, 2009, 17 (06): : 567 - 572
  • [3] Effect of Laser Parameters on the Corrosion Resistance of the ASTM F139 Stainless Steel
    Pieretti, Eurico Felix
    Pessine, Elisabete Jorge
    Correa, Olandir Vercino
    de Rossi, Wagner
    Martins das Neves, Maurcio David
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1221 - 1232
  • [4] Impact of surface treatment on the corrosion resistance of ASTM F138-F139 stainless steel for biomedical applications
    Pereda, M. D.
    Kang, K. W.
    Bonetto, R.
    Llorente, C.
    Bilmes, P.
    Gervasi, C.
    11TH INTERNATIONAL CONGRESS ON METALLURGY & MATERIALS SAM/CONAMET 2011, 2012, 1 : 446 - 453
  • [5] Combination of Electrochemical Noise and Acoustic Emission for Analysis of the Pitting Corrosion Behavior of an Austenitic Stainless Cast Steel
    Kietov, Volodymyr
    Mandel, Marcel
    Krueger, Lutz
    ADVANCED ENGINEERING MATERIALS, 2019, 21 (05)
  • [6] Mossbauer spectroscopy study on the corrosion resistance of plasma nitrided ASTM F138 stainless steel in chloride solution
    de Souza, S. D.
    Olzon Dionysio, M.
    Basso, R. L. O.
    de Souza, S.
    MATERIALS CHARACTERIZATION, 2010, 61 (10) : 992 - 999
  • [7] Effects of Heat Inputs on Phase Transformation and Resistance to Intergranular Corrosion of F316 Austenitic Stainless Steel
    Jeong, Gyue-Seog
    Lee, In-Sung
    Kim, Soon-Tae
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2020, 19 (03): : 146 - 155
  • [8] Comparative analysis of microstructure and corrosion resistance in laser-clad austenitic and martensitic stainless-steel coatings
    Wei, Runze
    Deng, Rui
    Li, Huan
    Liang, Jianguo
    Zhao, Chunjiang
    Ouyang, Changyao
    Bai, Qiaofeng
    VACUUM, 2024, 229
  • [9] Fitting corrosion resistance of high nitrogen f.c.c. phase in plasma source ion nitrided austenitic stainless steel
    Zhu, XM
    Lei, MK
    SURFACE & COATINGS TECHNOLOGY, 2000, 131 (1-3): : 400 - 403
  • [10] Control of grain boundary connectivity based on fractal analysis for improvement of intergranular corrosion resistance in SUS316L austenitic stainless steel
    Kobayashi, Shigeaki
    Kobayashi, Ryosuke
    Watanabe, Tadao
    ACTA MATERIALIA, 2016, 102 : 397 - 405