Comparative Evaluation of Microhardness of Two Conventional and Hydrophilic Fissure Sealants: An in vitro Study

被引:0
|
作者
Ashwini, K. [1 ]
Prabakar, Jayashri [1 ]
Jeevanandan, Ganesh [2 ]
机构
[1] Saveetha Univ, Saveetha Dent Coll & Hosp, Saveetha Inst Med & Tech Sci SIMATS, Dept Publ Hlth Dent, Chennai, Tamil Nadu, India
[2] Saveetha Univ, Saveetha Dent Coll & Hosp, Saveetha Inst Med & Tech Sci SIMATS, Dept Pedodont & Prevent Dent, Chennai, Tamil Nadu, India
关键词
Pit and fissure sealants; Microhardness; Thermocycling; Vickers hardness; CARIES; MICROLEAKAGE; DEPTH;
D O I
10.5530/jyp.2023.15.99
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Dental caries are highly prevalent and if left untreated, it can lead to harmful consequences. Micro-invasive types of dental caries treatment were adopted to cease the progression of decay. Fissure sealant helps to arrest incipient caries in pits and fissures. However, the major concern with conventional pit and fissure sealants is their technique sensitivity due to moisture contamination. Hence, hydrophilic sealants were introduced to overcome this drawback. The objective of the study is to compare and evaluate the micro hardness of conventional and hydrophilic pit and fissure sealants. Materials and Methods: Thirty sound molar teeth were grouped into 2 groups for which 15 molars were assigned to each group. Group I was allocated for 3M ESPE Clinpro hydrophobic sealants and Group II was Ultra-seal XT Hydro hydrophilic sealant. The prepared specimens were acid-etched with 37% phosphoric acid, followed by rinsing with water and finally air-dried before sealant placement. Each sealant material was then applied and light-cured. Vickers hardness test was used to estimate the microhardness of the sample with 200 gm load for 20 sec. Mann Whitney U test was done to find the difference between the two groups and the Wilcoxon test was used to find the difference within the group. Results: The differences between the mean microhardness value and Immediate, Aging time factor were found to be statistically non-significant. An increase in mean value was observed after ageing in both groups. A statistically significant difference (p<0.05) was observed within each group for the immediate and aging time factor. However, the mean microhardness aging value of Group II (30.04 +/- 5.31) was comparatively higher than Group I (28.01 +/- 4.02). Conclusion: There were no significant differences in the mean values of Group I and Group II for the immediate and aging time factor, but the aging time factor increased the mean values of both groups, and the difference was found to be statistically significant for both the groups. However, Hydrophilic pit and fissure sealants (Group II) had higher aging microhardness mean values compared to conventional sealants (Group I).
引用
收藏
页码:725 / 729
页数:5
相关论文
共 50 条
  • [1] Comparative Evaluation of the Viscosity and Length of Resin Tags of Conventional and Hydrophilic Pit and Fissure Sealants on Permanent Molars: An In vitro Study
    Prabakar, Jayashri
    John, Joseph
    Arumugham, Meignana, I
    Kumar, Pradeep R.
    Sakthi, D. Sri
    CONTEMPORARY CLINICAL DENTISTRY, 2018, 9 (03) : 388 - 394
  • [2] LABORATORY EVALUATION OF NEW FISSURE SEALANTS - MICROHARDNESS AND SETTING TIMES
    STRANG, R
    CUMMINGS, A
    STEPHEN, KW
    WYPER, DJ
    CARIES RESEARCH, 1984, 18 (02) : 178 - 179
  • [3] In vitro evaluation of wear resistance, microhardness and superficial roughness of different fissure sealants after aging
    Akcay, Hulya Cerci
    Aktoren, Oya
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2024, 48 (01) : 32 - 40
  • [4] In Vitro Comparative Evaluation of Er,Cr:YSSG Laser and Conventional Etching Methods on the Microleakage and Adaptation of Pit and Fissure Sealants
    Islam, Aylin
    Kizilelma, Zerhan
    Cetiner, Serap
    CYPRUS JOURNAL OF MEDICAL SCIENCES, 2018, 3 (02): : 85 - 89
  • [5] Comparative Evaluation of Microhardness of Hydrophilic Sealant and Flowable Composite on Permanent Molars- in vitro Study
    Rakshitha, V. S.
    Prabakar, Jayashri
    Jeevanandan, Ganesh
    Shanmugam, Rajeshkumar
    JOURNAL OF PIONEERING MEDICAL SCIENCES, 2024, 13 (07): : 192 - 198
  • [6] A Comparative Analysis of Penetration and Adaptation of Two Types of Light Cure Pit and Fissure Sealants: An In-vitro Study
    Sharma, Garima Mukesh
    Patil, Jayashree Rajesh
    Madhu, Priyanka Paul
    Chhabra, Kumar Gaurav
    Reche, Amit
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (43A) : 428 - 432
  • [7] Effects of application techniques and fissure types on the in vitro performance of two fissure sealants
    Duangthip, D
    Lussi, A
    AMERICAN JOURNAL OF DENTISTRY, 2004, 17 (02): : 137 - 142
  • [8] Comparative Evaluation of the Marginal Sealing Ability of two Commercially Available Pit and Fissure Sealants
    Sridhar, Lakshmi Priya
    Moses, Joyson
    Rangeeth, Bollam Nammalwar
    Sivakumar, Subramanian
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (09) : ZC1 - ZC4
  • [9] Comparative study of marginal leakage in pit and fissure sealants
    Myaki, SI
    Martins, CML
    Fava, M
    Balducci, I
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1020 - 1020
  • [10] Microleakage of pit and fissure sealants -: An in vitro study.
    Andrade, JP
    Dias, K
    Mello, HSA
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1101 - 1101