Intraoperative Cone-Beam Computed Tomography Assessment of Spinal Pedicle Screws Placement Precision Is in Full Agreement with Postoperative Computed Tomography Assessment

被引:1
|
作者
Ohashi, Hiroki [1 ]
Kawamura, Daichi [2 ]
Hatano, Keisuke [1 ]
Ohashi, So [2 ]
Tochigi, Satoru [2 ]
Isoshima, Akira [3 ]
Nagashima, Hiroyasu [4 ]
Otani, Katharina [5 ]
Karagiozov, Kostadin [1 ]
Tani, Satoshi [1 ]
Murayama, Yuichi [1 ]
机构
[1] Jikei Univ, Dept Neurosurg, Sch Med, Minato Ku, Tokyo, Japan
[2] Jikei Univ, Dept Neurosurg, Sch Med, Kashiwa Hosp, Kashiwa, Chile
[3] Omori Red Cross Hosp, Dept Neurosurg, Ota Ku, Tokyo, Japan
[4] Jikei Univ, Dept Neurosurg, Sch Med, Katsushika Med Ctr, Katsushika Ku, Tokyo, Japan
[5] Siemens Healthcare KK, AT Innovat Dept, Gate City Osaki West Tower,Shinagawa Ku, Tokyo, Japan
关键词
Pedicle screws; Robotic C-arm system; Spinal surgery; Spine; IMAGING TECHNIQUE; ACCURACY; RELIABILITY; FIXATION; GUIDANCE;
D O I
10.1016/j.wneu.2023.03.062
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
■ OBJECTIVE: To assess agreement between pedicle screw placement evaluated on postoperative computed tomography (CT) and on intraoperative cone-beam CT (CBCT) and compare procedure characteristics when using first-generation and second-generation robotic C-arm sys-tems in the hybrid operating room. ■ METHODS: All patients who received pedicle screws for spinal fusion at our institution between June 2009 and September 2019 and underwent intraoperative CBCT and postoperative CT were included. The CBCT and CT images were reviewed by 2 surgeons to assess the screw place-ment using the Gertzbein-Robbins and the Heary classifi-cations. Intermethod agreement of screw placement classifications as well as interrater agreement were assessed using Brennan-Prediger and Gwet agreement coefficients. Procedure characteristics using first -generation and second-generation generation robotic C-arm systems were compared. ■ RESULTS: Fifty-seven patients were treated with 315 pedicle screws at thoracic, lumbar, and sacral levels. No screw had to be repositioned. On CBCT, accurate place-ment was found for 309 screws (98.1%) using the Gertzbein-Robbins classification and 289 (91.7%) using the Heary classification and on CT, these were 307 (97.4%) and 293 (93.0%), respectively. Intermethod between CBCT and CT and interrater agreements between the 2 raters were almost perfect (>0.90) for all assessment. There were no significant differences in mean radiation dose (P = 0.83) and fluoroscopy time (P = 0.82), but length of surgery using the second-generation system was estimated at 107.7 mi -n utes (95% confidence interval, 31.9e183.5 minutes; P = 0.006) shorter. ■ CONCLUSIONS: Intraoperative CBCT provides accurate assessment of pedicle screw placement and enables intraoperative repositioning of misplaced screws.
引用
收藏
页码:E254 / E263
页数:10
相关论文
共 50 条
  • [1] Comparison of Cone-Beam Computed Tomography and Multislice Computed Tomography in the Assessment of Extremity Fractures
    Dubreuil, Thibaut
    Mouly, Jerome
    Ltaief-Boudrigua, Aicha
    Martinon, Amanda
    Tilhet-Coartet, Stephane
    Tazarourte, Karim
    Pialat, Jean-Baptiste
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 372 - 378
  • [2] Postoperative Computed Tomography Assessment of Pedicle Screw Placement Accuracy
    Lotfinia, Iraj
    Sayyahmelli, Sima
    Gavami, Mostafa
    TURKISH NEUROSURGERY, 2010, 20 (04) : 500 - 507
  • [3] Postoperative Assessment of Incisor Dental Implants Using Cone-Beam Computed Tomography
    Naitoh, Munetaka
    Nabeshima, Hiromitsu
    Hayashi, Hisashi
    Nakayama, Takehiko
    Kurita, Kenichi
    Ariji, Eiichiro
    JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (05) : 377 - 384
  • [4] Intraoperative Endodontic Applications of Cone-Beam Computed Tomography
    Ball, Randy L.
    Barbizam, Joao V.
    Cohenca, Nestor
    JOURNAL OF ENDODONTICS, 2013, 39 (04) : 548 - 557
  • [5] Role of postoperative multislice computed tomography in assessment of pedicle screw placement in spinal surgical fixation
    El Fiki, Inas M.
    Zaiton, Fatma
    Awadalla, Akram M.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2013, 44 (01): : 63 - 70
  • [6] Accuracy of fluoroscopic navigation of pedicle screws. Assessment of screw placement by computed tomography
    Fritsch, E
    Duchow, J
    Seil, R
    Grunwald, I
    Reith, W
    ORTHOPADE, 2002, 31 (04): : 385 - 391
  • [7] Cone-beam computed tomography for assessment of dens invaginatus in the Polish population
    Rozylo, T. Katarzyna
    Rozylo-Kalinowska, Ingrid
    Piskorz, Magdalena
    ORAL RADIOLOGY, 2018, 34 (02) : 136 - 142
  • [8] Assessment of vertical root fracture using cone-beam computed tomography
    Moudi, Ehsan
    Haghanifar, Sina
    Madani, Zahrasadat
    Alhavaz, Abdolhamid
    Bijani, Ali
    Bagheri, Mohammad
    IMAGING SCIENCE IN DENTISTRY, 2014, 44 (01) : 37 - 41
  • [9] Cone-Beam Computed Tomography (CBCT) Imaging for the Assessment of Periodontal Disease
    Sousa Melo S.L.
    Rovaris K.
    Javaheri A.M.
    de Rezende Barbosa G.L.
    Current Oral Health Reports, 2020, 7 (4) : 376 - 380
  • [10] Accessory mental foramen assessment using cone-beam computed tomography
    Naitoh, Munetaka
    Hiraiwa, Yuichiro
    Aimiya, Hidetoshi
    Gotoh, Kenichi
    Ariji, Eiichiro
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (02): : 289 - 294