Automated detection and analysis of subdural hematomas using a machine learning algorithm

被引:9
|
作者
Colasurdo, Marco [1 ]
Leibushor, Nir [2 ]
Robledo, Ariadna [3 ]
Vasandani, Viren [3 ]
Luna, Zean Aaron [3 ]
Rao, Abhijit S. [3 ]
Garcia, Roberto [3 ]
Srinivasan, Visish M. [4 ]
Sheth, Sunil A. [5 ]
Avni, Naama [2 ]
Madziva, Moleen [2 ]
Berejick, Mor [2 ]
Sirota, Goni [2 ]
Efrati, Aielet [2 ]
Meisel, Avraham [2 ]
Shaltoni, Hashem
Kan, Peter [3 ,6 ]
机构
[1] Univ Texas Med Branch, Dept Radiol, Div Neuroradiol, Galveston, TX USA
[2] Viz Ai Inc, San Francisco, CA USA
[3] Univ Texas Med Branch, Dept Neurol, Galveston, TX USA
[4] St Josephs Hosp, Barrow Neurol Inst, Dept Neurosurg, Phoenix, AZ USA
[5] Univ Texas Hlth Sci Ctr, McGovern Med Sch, Dept Neurol, Houston, TX USA
[6] Univ Texas Med Branch, Galveston, TX 77555 USA
关键词
subdural; hemorrhage; trauma; technology; CT; AI; artificial intelligence; ARTIFICIAL-INTELLIGENCE; EPIDEMIOLOGY; MANAGEMENT; DIAGNOSIS;
D O I
10.3171/2022.8.JNS22888
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Machine learning algorithms have shown groundbreaking results in neuroimaging. Herein, the authors evaluate the performance of a newly developed convolutional neural network (CNN) to detect and quantify the thickness, volume, and midline shift (MLS) of subdural hematoma (SDH) from noncontrast head CT (NCHCT).METHODS NCHCT studies performed for the evaluation of head trauma in consecutive patients between July 2018 and April 2021 at a single institution were retrospectively identified. Ground truth determination of SDH, thickness, and MLS was established by the neuroradiology report. The primary outcome was performance of the CNN in detecting SDH in an external validation set, as measured using area under the receiver operating characteristic curve analysis. Secondary outcomes included accuracy for thickness, volume, and MLS.RESULTS Among 263 cases with valid NCHCT according to the study criteria, 135 patients (51%) were male, the mean (+/- standard deviation) age was 61 +/- 23 years, and 70 patients were diagnosed with SDH on neuroradiologist evaluation. The median SDH thickness was 11 mm (IQR 6 mm), and 16 patients had a median MLS of 5 mm (IQR 2.25 mm). In the in-dependent data set, the CNN performed well, with sensitivity of 91.4% (95% CI 82.3%-96.8%), specificity of 96.4% (95% CI 92.7%-98.5%), and accuracy of 95.1% (95% CI 91.7%-97.3%); sensitivity for the subgroup with an SDH thickness above 10 mm was 100%. The maximum thickness mean absolute error was 2.75 mm (95% CI 2.14-3.37 mm), whereas the MLS mean absolute error was 0.93 mm (95% CI 0.55-1.31 mm). The Pearson correlation coefficient computed to determine agreement between automated and manual segmentation measurements was 0.97 (95% CI 0.96-0.98).CONCLUSIONS The described Viz.ai SDH CNN performed exceptionally well at identifying and quantifying key fea-tures of SDHs in an independent validation imaging data set.
引用
收藏
页码:1077 / 1084
页数:8
相关论文
共 50 条
  • [1] Validation of an automated machine learning algorithm for the detection and analysis of cerebral aneurysms
    Colasurdo, Marco
    Shalev, Daphna
    Robledo, Ariadna
    Vasandani, Viren
    Luna, Zean Aaron
    Rao, Abhijit S.
    Garcia, Roberto
    Edhayan, Gautam
    Srinivasan, Visish M.
    Sheth, Sunil A.
    Donner, Yoni
    Bibas, Orin
    Limzider, Nicole
    Shaltoni, Hashem
    Kan, Peter
    JOURNAL OF NEUROSURGERY, 2023, 139 (04) : 1002 - 1009
  • [2] Important Predictors of In-Hospital Mortality in Patients With Acute Subdural Hematomas Using Machine Learning
    McPheters, Aaron
    Donovan, Andrew
    Khattar, Nicolas K.
    Shpilberg, Jacob R.
    John, Kevin
    Do, Quan H.
    Patton, Daniella
    Sieg, Emily P.
    NEUROSURGERY, 2019, 66 : 100 - 101
  • [3] Automated detection of Fuchs' dystrophy through a machine learning algorithm using Pentacam data
    Hidalgo, Irene Ruiz
    Perez, Pablo Rodriguez
    Rozema, Jos J.
    Koppen, Carina
    Dhubhghaill, Sorcha S. Ni
    Zakaria, Nadia
    Tassignon, Marie-Jose B. R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [4] Automated Essay Grading using Machine Learning Algorithm
    Ramalingam, V. V.
    Pandian, A.
    Chetry, Prateek
    Nigam, Himanshu
    PROCEEDINGS OF THE 10TH NATIONAL CONFERENCE ON MATHEMATICAL TECHNIQUES AND ITS APPLICATIONS (NCMTA 18), 2018, 1000
  • [5] Automated detection of anomalies in cervix cells using image analysis and machine learning
    Moscon L.M.
    Macedo N.D.
    Nunes C.S.M.
    Boasquevisque P.C.R.
    de Andrade T.U.
    Endringer D.C.
    Lenz D.
    Comparative Clinical Pathology, 2019, 28 (1) : 177 - 182
  • [6] An Algorithm for Treatment of Symptomatic Chronic Subdural Hematomas
    Wang, Alice S.
    Rahman, Raphia
    Ueno, Arisa
    Farr, Saman
    Duong, Jason
    Miulli, Dan E.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [7] Automated Detection of Facial Weakness Using Machine Learning
    Uribe, Omar
    McDonald, Mark
    Zhuang, Yan
    Lin, Iris
    Arteaga, Daniel
    Dalrymple, William
    Worrall, Bradford
    Rohde, Gustavo
    Southerland, Andrew
    NEUROLOGY, 2018, 90
  • [8] Automated Detection of Facial Weakness Using Machine Learning
    Uribe, Omar A.
    McDonald, Mark M.
    Zhuang, Yan
    Lin, Iris L.
    Arteaga, Daniel F.
    Dalrymple, William A.
    Worrall, Bradford B.
    Rohde, Gustavo K.
    Southerland, Andrew M.
    STROKE, 2018, 49
  • [9] Automated Detection of Racial Microaggressions using Machine Learning
    Ali, Omar
    Scheidt, Nancy
    Gegov, Alexander
    Haig, Ella
    Adda, Mo
    Aziz, Benjamin
    2020 IEEE SYMPOSIUM SERIES ON COMPUTATIONAL INTELLIGENCE (SSCI), 2020, : 2477 - 2484
  • [10] Automated detection of counterfeit ICs using machine learning
    Ahmadi, Bahar
    Javidi, Bahram
    Shahbazmohamadi, Sina
    MICROELECTRONICS RELIABILITY, 2018, 88-90 : 371 - 377