Measurement and transformation of continuously modulated fields using a short-time measurement approach

被引:0
|
作者
Faul, Fabian T. [1 ]
Daubmeier, Jana [1 ]
Eibert, Thomas F. [1 ]
机构
[1] Tech Univ Munich, Chair High Frequency Engn, Dept Elect & Comp Engn, D-80290 Munich, Germany
关键词
ANTENNA; DIAGNOSTICS;
D O I
10.5194/ars-20-9-2023
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Near-field measurements, which are performed in-situ, may suffer from the fact that the antenna under test (AUT) cannot be accessed to transmit or receive a specifically tailored test signal. In some scenarios, it might also be desired to test the AUT during its real operation state, especially when it comes to the verification of antenna systems. Therefore, the need to handle time- and space-modulated fields in combination with a time-harmonic near-field to far-field transformation (NFFFT) arises. For the case where unmanned aerial vehicles (UAVs) carry the field probe in in-situ measurement scenarios, long observation times, required for the resolution of the frequency spectra of modulated fields, are detrimental due to the UAV movement resulting in blurred measurement positions. The short-time measurement (STM) approach, presented in this article, offers a way to transform the measured field data using a time-harmonic NFFFT with short observation times for the collection of the individual field samples.Measurements are shown which demonstrate the applicability of the STM approach for the measurement and transformation of continuously time-modulated fields in different measurement scenarios.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 50 条
  • [1] Errors and Prerequisites of the Short-Time Measurement and Transformation of Continuously Modulated Fields
    Faul, Fabian T.
    Eibert, Thomas F.
    2021 ANTENNA MEASUREMENT TECHNIQUES ASSOCIATION SYMPOSIUM (AMTA), 2021,
  • [2] Continuous measurement of short-time BOD
    (Publ by Pergamon Press Inc, Tarrytown, NY, USA):
  • [3] SHORT-TIME MEASUREMENT OF TIME DILATION IN AN EARTH SATELLITE
    BADESSA, RS
    KENT, RL
    NOWELL, JC
    PHYSICAL REVIEW LETTERS, 1959, 3 (02) : 79 - 80
  • [5] Potential barrier classification by short-time measurement
    Granot, E
    Marchewka, A
    PHYSICAL REVIEW A, 2006, 73 (03):
  • [6] INSTRUMENT FOR THE MEASUREMENT OF SHORT-TIME FREQUENCY INSTABILITY
    KANEVSKII, AI
    KLEIMAN, AS
    KREINES, DL
    KALABUKHOV, LI
    PESTOVSKII, VI
    TIMOFEEV, EP
    FERTIK, NS
    YAKIMENKO, AM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1978, 21 (06) : 1673 - 1673
  • [7] Near-field measurement of continuously modulated fields employing the time-harmonic near- to far-field transformation
    Faul, Fabian T.
    Kornprobst, Jonas
    Fritzel, Torsten
    Steiner, Hans-Juergen
    Strauss, Ruediger
    Weiss, Alexander
    Geise, Robert
    Eibert, Thomas F.
    ADVANCES IN RADIO SCIENCE, 2019, 17 : 83 - 89
  • [8] SHORT-TIME MEASUREMENT OF FATIGUE LIMIT OF METALS USING INFRARED THERMOGRAPHY
    LUONG, MP
    REVUE DE METALLURGIE-CAHIERS D INFORMATIONS TECHNIQUES, 1995, 92 (02): : 203 - 212
  • [9] SHORT-TIME MEASUREMENT OF FREQUENCY AND AMPLITUDE IN THE PRESENCE OF NOISE
    ZAYEZDNY, AM
    ADLER, Y
    DRUCKMANN, I
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (03) : 397 - 402
  • [10] Measurement for Radar Target Identification using Short-Time Matrix Pencil Method
    Kheawprae, Feaveya
    Boonpoonga, Akkarat
    Sangchai, Woranart
    2015 IEEE CONFERENCE ON ANTENNA MEASUREMENTS & APPLICATIONS (CAMA), 2015,