Computed tomographic evaluation of heart size in clinically healthy cats

被引:3
|
作者
Wanglerm, Aphisit [1 ]
Samachikthummakun, Chawanwith [1 ]
Kitnitchee, Zen [1 ]
Sirinitikorn, Thiranan [1 ]
Junnong, Sapawut [1 ]
Sutthigran, Somchin [2 ]
Choisunirachon, Nan [2 ]
Thanaboonnipat, Chutimon [2 ]
机构
[1] Chulalongkorn Univ, Fac Vet Sci, Bangkok, Thailand
[2] Chulalongkorn Univ, Fac Vet Sci, Dept Vet Surg, Bangkok, Thailand
关键词
Cats; Computer tomography; Feline heart; Transverse vertebral heart score; Vertebral heart score; RADIOGRAPHY; DISEASE; CT;
D O I
10.5455/OVJ.2023.v13.i3.10
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Computed tomography (CT) is currently one of the most useful diagnostic imaging tools for evaluating cardiac disorders in humans and animals. However, studies concerning CT and the feline heart remain scarce.Aim: To create measuring techniques for the feline heart size on CT and to determine the relationships of feline heart size observed on CT with internal parameters including age, bodyweight (BW), and sex.Methods: Four parameters observed on CT including thoracic height/width ratio (THW), relative heart area (RHA), CT vertebral heart score (ctVHS), transverse vertebral heart score (tVHS) in 1.25 mm slice thickness, and both pre -and post-contrast enhanced images were examined. Additionally, radiographic vertebral heart score (rVHS) was also evaluated.Results: THW was significantly influenced by age (p < 0.05). RHA was affected by age and gonadal status of cats (p = 0.001 and p = 0.016, respectively). Age also significantly affected tVHS (p = 0.038). Interestingly, ctVHS was not influenced by age, sex, gonadal status, or BW. tVHS and ctVHS had significantly moderately positive correlations with rVHS (r = 0.476; p = 0.048 and r = 0.6112; p = 0.011, respectively). THW and RHA had non-significant correlations with rVHS (r = 0.2642; p = 0.302 and r = 0.1920; p = 0.455, respectively).Conclusion: CT heart size evaluation can be performed in both pre-and post-contrast enhanced images of 1.25 mm slice thickness. tVHS and ctVHS are recommended for feline heart size in clinical
引用
收藏
页码:337 / 347
页数:11
相关论文
共 50 条
  • [1] Computed tomographic evaluation of cerebral ventricular size in clinically normal calves
    Lee, Ki-Ja
    Lee, Young-Won
    Choi, Ho-Jung
    Kishimoto, Miori
    Shimizu, Junichiro
    Iwasaki, Toshiroh
    Miyake, Yoh-Ichi
    Yamada, Kazutaka
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2010, 71 (02) : 135 - 137
  • [2] Use of "vertebral heart size" for cardiac evaluation of healthy cats
    de Menezes, Gabriel Ferreira
    Fayad Milken, Vanessa Martins
    Mantovani, Matheus Matioli
    MEDICINA VETERINARIA-RECIFE, 2011, 5 (04): : 89 - 92
  • [3] Quantitative computed tomographic of the renal cortex in healthy dogs and cats
    De Oliveira, Daniel Capucho
    Vescovi Sellos Costa, Lorena Adao
    Giannotti, Juliana di Giorgio
    Teixeira, Marcelo Weinstein
    Costa, Fabiano Sellos
    MEDICINA VETERINARIA-RECIFE, 2011, 5 (04): : 81 - 83
  • [4] Computed tomographic appearance of abdominal lymph nodes in healthy cats
    Perlini, Michael
    Bugbee, Andrew
    Secrest, Scott
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2018, 32 (03) : 1070 - 1076
  • [5] Computed tomographic evaluation of pectus excavatum in 14 cats
    Komsta, Renata
    Lojszczyk, Anna
    Debiak, Piotr
    Twardowski, Piotr
    Lisiak, Barbara
    PLOS ONE, 2022, 17 (01):
  • [6] Computed Tomographic Imaging Characteristics of the Thyroid Glands in Clinically Normal Van Cats
    Yilmaz, Osman
    KAFKAS UNIVERSITESI VETERINER FAKULTESI DERGISI, 2021, 27 (05) : 617 - 624
  • [7] Comparative ultrasonographic and computed tomographic images of the adrenal glands of healthy cats
    Phoomvuthisarn, Panrawee
    Komin, Kiatpichet
    Choisunirachon, Nan
    THAI JOURNAL OF VETERINARY MEDICINE, 2018, 48 (04): : 689 - 698
  • [8] Computed tomographic evaluation of pancreatic perfusion in healthy dogs
    Kloer, Timothy B.
    Rao, Sangeeta
    Twedt, David C.
    Marolf, Angela J.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2020, 81 (02) : 131 - 138
  • [9] Dynamic computed tomographic evaluation of the pituitary gland in healthy dogs
    van der Vlugt-Meijer, RH
    Meij, BP
    Voorhout, G
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2004, 65 (11) : 1518 - 1524
  • [10] Computed Tomographic Evaluation of the Accuracy of Minimally Invasive Sacroiliac Screw Fixation in Cats
    Wills, Daniel J.
    Neville-Towle, Jack
    Podadera, Juan
    Johnson, Kenneth A.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2022, 35 (02) : 119 - 127