SGReg: segmentation guided 3D/2D rigid registration for orthogonal X-ray and CT images in spine surgery navigation

被引:5
|
作者
Mi, Jia [1 ,2 ,3 ]
Yin, Wenhao [1 ,2 ,3 ]
Zhao, Lei [1 ,2 ,3 ]
Chen, Yangfan [1 ,2 ,3 ]
Zhou, Yujia [1 ,2 ,3 ]
Feng, Qianjin [1 ,2 ,3 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou 510515, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Guangzhou, Peoples R China
[3] Southern Med Univ, Guangdong Prov Engn Lab Med Imaging & Diagnost Tec, Guangzhou, Peoples R China
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 13期
基金
中国国家自然科学基金;
关键词
3D; 2D registration; surgery navigation; vertebrae segmentation; 3-D/2-D REGISTRATION; CHALLENGES;
D O I
10.1088/1361-6560/acd29d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. One of the essential technologies in various image-guided spine surgeries is the rigid registration of 3D pre-operative CT and 2D intra-operative X-ray images. The 3D/2D registration is patterned as two essential tasks, that is, dimensional correspondence establishment and estimation of the 3D pose. 3D data is projected to 2D for dimensional correspondence by most of the existing methods, which makes pose parameters difficult to estimate caused by the loss of spatial information. This work aims to develop a reconstruction based 3D/2D registration method for spine surgery navigation. Approach. A novel segmentation-guided 3D/2D registration (SGReg) method for orthogonal X-ray and CT images was proposed based on reconstruction. SGReg consists of a bi-path segmentation network and an inter-path multi-scale pose estimation module. The X-ray segmentation path in the bi-path segmentation network reconstructs 3D spatial information from 2D orthogonal X-ray images to segmentation masks; meanwhile, the CT segmentation path predicts segmentation masks from 3D CT images, thereby bringing the 3D/2D data into dimensional correspondence. In the inter-path multi-scale pose estimation module, the features from the two segmentation paths are integrated, and the pose parameters are directly regressed under the guidance of the coordinate information. Main result. We evaluated SGReg using a public dataset CTSpine1k and compared the registration performance with other methods. SGReg achieved considerable improvement over other methods with great robustness. Significance We have proposed an end-to-end 3D/2D registration framework named SGReg. Based on the idea of reconstruction, SGReg performs a unified framework between dimensional correspondence establishment and direct pose estimation in 3D space, showing significant potential in spine surgery navigation.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] 2D/3D registration based on biplanar X-ray and CT images for surgical navigation
    Yang, Demin
    Shi, Haochen
    Zeng, Bolun
    Chen, Xiaojun
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 257
  • [2] Rigid 2D/3D registration of intraoperative digital X-ray images and preoperative CT and MR images
    Tomazevic, D
    Likar, B
    Pernus, F
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 507 - 517
  • [3] An approach to 2D/3D registration of a vertebra in 2D x-ray fluoroscopies with 3D CT images
    Weese, J
    Buzug, TM
    Lorenz, C
    Fassnacht, C
    CVRMED-MRCAS'97: FIRST JOINT CONFERENCE - COMPUTER VISION, VIRTUAL REALITY AND ROBOTICS IN MEDICINE AND MEDICAL ROBOTICS AND COMPUTER-ASSISTED SURGERY, 1997, 1205 : 119 - 128
  • [4] Spectral-based 2D/3D X-ray to CT image rigid registration
    Freiman, M.
    Pele, O.
    Hurvitz, A.
    Werman, M.
    Joskowicz, L.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [5] 2D/3D registration of pre-operative CT images and intra-operative x-ray projections for image guided surgery
    Weese, J
    Penney, GP
    Buzug, TM
    Fassnacht, C
    Lorenz, C
    CAR '97 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1997, 1134 : 833 - 838
  • [6] Image Guided Mitral Valve Replacement: Registration of 3D Ultrasound and 2D X-ray Images
    Dormer, James D.
    Bhuiyan, Md Fiaz Islam
    Rahman, Nahian
    Deaton, Nancy
    Sheng, Jun
    Padala, Muralidhar
    Desai, Jaydev P.
    Fei, Baowei
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [7] Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data
    van der Bom, M. J.
    Pluim, J. P. W.
    Gounis, M. J.
    de Kraats, E. B. van
    Sprinkhuizen, S. M.
    Timmer, J.
    Homan, R.
    Bartels, L. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04): : 1031 - 1043
  • [8] 2D/3D Non-Rigid Image Registration via Two Orthogonal X-ray Projection Images for Lung Tumor Tracking
    Dong, Guoya
    Dai, Jingjing
    Li, Na
    Zhang, Chulong
    He, Wenfeng
    Liu, Lin
    Chan, Yinping
    Li, Yunhui
    Xie, Yaoqin
    Liang, Xiaokun
    BIOENGINEERING-BASEL, 2023, 10 (02):
  • [9] Effective intensity-based 2D/3D rigid registration between fluoroscopic X-ray and CT
    Knaan, D
    Joskowicz, L
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 1, 2003, 2878 : 351 - 358
  • [10] Effects of x-ray and CT image enhancements on the robustness and accuracy of a rigid 3D/2D image registration
    Kim, J
    Yin, FF
    Zhao, Y
    Kim, JH
    MEDICAL PHYSICS, 2005, 32 (04) : 866 - 873