Monte Carlo dosimetry of a novel Yttrium-90 disc source for episcleral brachytherapy

被引:3
|
作者
Chang, Xiangyun [1 ,2 ]
Huang, Lyu [2 ]
Liu, Jian [3 ]
Cao, Yijian [1 ,2 ,4 ]
Chang, Jenghwa [1 ,2 ,4 ,5 ]
机构
[1] Hofstra Univ, Dept Phys & Astron, Med Phys Program, Hempstead, NY USA
[2] Northwell Hlth, Radiat Med, Lake Success, NY 11042 USA
[3] Rhode Isl Hosp, Radiat Oncol, Providence, RI USA
[4] Zucker Sch Med Hofstra Northwell, Radiat Med, Lake Success, NY USA
[5] Northwell Hlth, Dept Radiat Med, 450 Lakeville Rd, Lake Success, NY 11042 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 12期
关键词
HDR brachytherapy; Monte Carlo; Y-90; UPDATE;
D O I
10.1002/acm2.14140
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo calculate the dose distribution using Monte Carlo simulations for a novel high-dose-rate Yttrium-90 (Y-90) disc source recently developed for episcleral brachytherapy and provide a lookup table for treatment planning.MethodsMonte Carlo simulations were performed to calculate the in-water dose distribution of the Y-90 disc source using the "GATE", a software based on the "Geant4" Monte Carlo simulation toolkit developed by the international OpenGATE collaboration. The geometry of this novel beta source, its capsule, and the surrounding water medium were accurately modeled in the simulation input files. The standard Y-90 element beta spectrum from ICRU 72 was used, and the physics processes for beta and photon interactions with matters were all included. The dose distribution of this Y-90 disc source was measured in a separate study using Gafchromic EBT-3 films and the results were reported elsewhere. To match the setup of the experiment, a Gafchromic EBT-3 film was also included in the simulation geometry. The simulated dose profiles were exported from the 3D dose distribution results and compared with the measured dose profiles. Transverse dose profiles at different distances from the seed surface were also obtained to study the lateral coverage of the source.ResultsThe measured percent depth dose (PDD) curves along the central axis perpendicular to the surface of the Y-90 disc were constructed from the experimental and simulated data, and normalized to the reference point at 1 mm from the source capsule. Both PDD curves agreed well up to 4 mm from the source surface (maximum difference & PLUSMN; 10%) but deviated from each other beyond 4 mm. The deviation might be caused by the increased measurement uncertainty in the low-dose region. The dose rate at the reference point calculated from the Monte Carlo simulation was 1.09 cGy/mCi-s and agreed very well with the measured dose rate of 1.05 cGy/mCi-s. If the 80% isodose line is selected as the lateral coverage, the lateral dose coverage is maximal (& SIM;4.5 mm) at the plane next to the source surface, and gradually decreases with the increasing distance, approaching 3.5 mm when the plane is 5 mm from the 6-mm diameter source surface.ConclusionMonte Carlo simulations were successfully performed to confirm the measured PDD curve of the novel Y-90 disc source. This simulation work laid a solid foundation for characterizing the full dosimetry parameters of this source for episcleral brachytherapy applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Monte Carlo Simulation and Validation of a Novel Yttrium-90 Source for Use in a Conformal Superficial Brachytherapy Device
    Rogers, B.
    Alaei, P.
    Chmura, J.
    Ehler, E.
    Lawrence, J.
    Wilke, C.
    Ferreira, C.
    MEDICAL PHYSICS, 2019, 46 (06) : E495 - E495
  • [2] Yttrium-90 Episcleral Plaque Brachytherapy for Choroidal Melanoma
    Finger, Paul T.
    JOURNAL OF VITREORETINAL DISEASES, 2024, 8 (02) : 210 - 214
  • [3] Use Monte Carlo Simulations to Investigate the Energy Dependence of EBT-3 Film Dosimetry for a Y-90 Disc Source for Episcleral Brachytherapy
    Chang, X.
    Huang, L.
    Cao, Y.
    Liu, J.
    Chang, J.
    MEDICAL PHYSICS, 2022, 49 (06) : E816 - E816
  • [4] Monte Carlo dosimetry of a new 90Y brachytherapy source
    Wu Junxiang
    You Shihu
    Huang Jing
    Long Fengxiang
    Wang Chengkai
    Wu Zhangwen
    Hou Qing
    Gou Chengjun
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (05) : 397 - 406
  • [5] A Simple Monte-Carlo Treatment Planning System for Episcleral Brachytherapy Using a Novel High-Dose-Rate Y-90 Disc Source
    Polanco, M.
    Chang, X.
    Chang, J.
    MEDICAL PHYSICS, 2024, 51 (10) : 7819 - 7819
  • [6] Optimization of Yttrium-90 Bremsstrahlung Imaging with Monte Carlo Simulations
    Rault, E.
    Vandenberghe, S.
    Staelens, S.
    Lemahieu, I.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 500 - 504
  • [7] Monte Carlo calculation of dosimetry parameters for a brachytherapy source
    A. V. Belousov
    A. A. Kalachev
    A. S. Osipov
    Moscow University Physics Bulletin, 2014, 69 : 535 - 541
  • [8] Uncertainties of Monte Carlo simulation for brachytherapy source dosimetry
    Rachabatthula, V
    Meigooni, A
    MEDICAL PHYSICS, 2004, 31 (06) : 1732 - 1732
  • [9] Monte Carlo calculation of dosimetry parameters for a brachytherapy source
    Belousov, A. V.
    Kalachev, A. A.
    Osipov, A. S.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2014, 69 (06) : 535 - 541
  • [10] Monte Carlo Simulation of Liver Dosimetry with Yttrium-90 Radionuclide Using Gate: 3D Phantom
    Karadeniz-Yildirim, Ayse
    Ozkorucuklu, Suat
    Tanyildizi-Kokkulunk, Handan
    Demir, Mustafa
    Yasar, Dogan
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2024, 51 (01) : 30 - 37