Homogeneous Bridging Induces Compact and Scalable Perovskite Thick Films for X-Ray Flat-Panel Detectors

被引:17
|
作者
Chai, Yingjun [1 ]
Jiang, Chaoyan [2 ]
Hu, Xudong [1 ]
Han, Jiguang [1 ]
Wang, Yao [1 ]
Yang, Wanqiu [1 ]
Li, Chongkang [1 ]
Zeng, Haibo [1 ]
Li, Xiaoming [1 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Mat Sci & Engn, MIIT Key Lab Adv Display Mat & Devices, Nanjing 210094, Peoples R China
[2] Ningbo Univ, Sch Mat Sci & Chem Engn, Ningbo 315211, Peoples R China
关键词
homogeneous bridging; hybrid perovskite; slurry formulation; thick films; X-ray detectors; METAL HALIDE PEROVSKITES; SENSITIVITY; PHASE;
D O I
10.1002/smll.202305357
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Solution-processed organic-inorganic hybrid perovskite polycrystalline thick films have shown great potential in X-ray detection. However, the preparation of compact perovskite thick films with large area is still challenging due to the limitation of feasible ink formulation and pinholes caused by solvent volatilization. Post-treatment and hot-pressing are usually involved to improve the film quality, which is however unsuitable for subsequent integration. In this work, a homogeneous bridging strategy is developed to prepare compact perovskite films directly. A stable perovskite slurry with suitable viscosity consisting of undissolved grains and supersaturated solution is formed by adding a weak coordination solvent to the pre-synthesized microcrystalline powders. Small perovskite grains in situ grow from the saturated solution during the annealing, filling the pinholes and connecting the surrounding original grains. As a result, large-area perovskite thick film with tight grain arrangement and ultralow current drift is blade-coated to achieve X-ray imaging. The optimal device displays an impressive mobility-lifetime product of 2.2 x 10-3 cm2 V-1 and a champion ratio of sensitivity to the dark current density of 2.23 x 1011 mu C Gyair-1 A-1. This work provides a simple and effective route to prepare high-quality perovskite thick films, which is instructive for the development of perovskite-based X-ray flat-panel detectors. In this work, the authors use a little solvent and pre-synthesized microcrystalline powders to prepare perovskite slurry, which exhibits a suitable viscosity for blade-coating. The obtained thick film shows a compact and uniform structure rivaling that after hot-pressing treatment. Finally, large-area thick film with tight grain arrangement is integrated with the thin-film transistor (TFT) substrate and achieves X-ray imaging.image
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Homogeneous Bridging Induces Compact and Scalable Perovskite Thick Films for X-Ray Flat-Panel Detectors
    Chai, Yingjun
    Jiang, Chaoyan
    Hu, Xudong
    Han, Jiguang
    Wang, Yao
    Yang, Wanqiu
    Li, Chongkang
    Zeng, Haibo
    Li, Xiaoming
    SMALL, 2023,
  • [2] Flat-panel detectors in X-ray systems
    Spahn, M
    Heer, V
    Freytag, R
    RADIOLOGE, 2003, 43 (05): : 340 - +
  • [3] Direct Ink Writing of Single-Crystal-Assembled Perovskite Thick Films for High-Performance X-ray Flat-Panel Detectors
    Wang, Yulong
    Xu, Xiuwen
    Xing, Guansheng
    Lin, Shanxiao
    Yan, Yurou
    Zhou, Quan
    Chen, Jianmei
    Zhu, Wenjuan
    Chen, Bing
    Liu, Shujuan
    Zhao, Qiang
    ADVANCED FUNCTIONAL MATERIALS, 2025,
  • [4] Scalable Fabrication of Metal Halide Perovskites for Direct X-ray Flat-Panel Detectors: A Perspective
    Haruta, Yuki
    Kawakami, Mioko
    Nakano, Yuui
    Kundu, Soumya
    Wada, Shinji
    Ikenoue, Takumi
    Miyake, Masao
    Hirato, Tetsuji
    Saidaminov, Makhsud, I
    CHEMISTRY OF MATERIALS, 2022, 34 (12) : 5323 - 5333
  • [5] Direct-conversion flat-panel X-ray image detectors
    Kasap, SO
    Rowlands, JA
    IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 2002, 149 (02): : 85 - 96
  • [6] Scintillator-based flat-panel x-ray imaging detectors
    Granfors, Paul R.
    Albagli, Douglas
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2009, 17 (06) : 535 - 542
  • [7] A semiempirical linear model of indirect, flat-panel x-ray detectors
    Huang, Shih-Ying
    Yang, Kai
    Abbey, Craig K.
    Boone, John M.
    MEDICAL PHYSICS, 2012, 39 (04) : 2108 - 2118
  • [8] Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors
    Zhao, W
    DeCrescenzo, G
    Rowlands, JA
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 9 - 20
  • [9] Close-spaced sublimation growth and characterization of polycrystalline Cd1-xZnxTe thick films for flat-panel x-ray detectors
    Okamoto, Tamotsu
    Kono, Makoto
    Jibiki, Takayuki
    Imai, Kiyokazu
    Kishihara, Hiroyuki
    Kaino, Masatomo
    Tokuda, Satoshi
    Sato, Toshiyuki
    Japanese Journal of Applied Physics, 2008, 47 (4 PART 1): : 2079 - 2082
  • [10] Close-spaced sublimation growth and characterization of polycrystalline Cd1-xZnxTe thick films for flat-panel X-ray detectors
    Okamoto, Tamotsu
    Kono, Makoto
    Jibiki, Takayuki
    Imai, Kiyokazu
    Kishihara, Hiroyuki
    Kaino, Masatomo
    Tokuda, Satoshi
    Sato, Toshiyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (04) : 2079 - 2082