A highly sensitive immunochromatographic assay for lead ions in drinking water based on antibody-oriented probe and silver enhancement

被引:2
|
作者
Li, Yangyang [1 ]
Zhu, Zhengwei [2 ]
Qu, Wenli [1 ]
Yang, Qing [3 ,4 ]
Liu, Yan [3 ,4 ,5 ]
Wang, Qiao [3 ,4 ]
Duan, Shuo [3 ,4 ]
Wu, Jine [3 ,4 ]
Gong, Zhiyong [3 ,4 ]
Xu, Lin [3 ,4 ]
机构
[1] Wuhan Polytech Univ, Coll Food Sci & Engn, Xuefunan Rd 68, Wuhan 430023, Peoples R China
[2] Hubei Prov Inst Food Supervis & Test, Wuhan 430075, Peoples R China
[3] Minist Educ, Key Lab Deep Proc Major Grain & Oil, Wuhan 430023, Peoples R China
[4] Hubei Key Lab Proc & Transformat Agr Prod, Wuhan 430023, Peoples R China
[5] Key Res Inst Humanities & Social Sci Hubei Prov, Food Safety Res Ctr, Wuhan 430023, Peoples R China
基金
中国国家自然科学基金;
关键词
Silver enhancement; Antibody-oriented probe; Immunochromatographic assay; Lead ions; LATERAL FLOW IMMUNOASSAY; STRIP ASSAY;
D O I
10.1007/s00217-023-04351-5
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Lead ions are a toxic metal that can enter the human body through the diet and negatively impact human health. A wide variety of foods, such as vegetables, meat, aquatic product, and drinking water, can be contaminated with lead ions. In this study, a highly sensitive immunochromatographic assay (ICA) based on antibody-oriented probe and silver enhancement was established for the qualitative and quantitative determination of lead ions in drinking water. The recombinant protein A (PrA) was used in probe preparation to improve antibody bioactivity while silver enhancement method was applied to enhance the signal reporter of ICA. It was determined that the visual limit of detection and the scanning limit of quantification of the ICA based on antibody-oriented probe and silver enhancement for lead ions in drinking water were 0.2 ng/mL and 0.08 ng/mL, respectively. The results obtained from developed ICA strip and ICP-MS had no obvious difference using statistical analysis of t test. Compared to previously reported ICA methods for lead ions, the developed ICA method enabled analyzing lead ions in drinking water with a superior sensitivity and detection range.
引用
收藏
页码:3097 / 3103
页数:7
相关论文
共 23 条
  • [1] A highly sensitive immunochromatographic assay for lead ions in drinking water based on antibody-oriented probe and silver enhancement
    Yangyang Li
    Zhengwei Zhu
    Wenli Qu
    Qing Yang
    Yan Liu
    Qiao Wang
    Shuo Duan
    Jine Wu
    Zhiyong Gong
    Lin Xu
    European Food Research and Technology, 2023, 249 : 3097 - 3103
  • [2] Universal probe with oriented antibody to improve the immunochromatographic assay of lead ions in Procambarus clarkii
    Li, Yangyang
    Zhu, Zhengwei
    Qu, Wenli
    Yang, Qing
    Liu, Yan
    Wang, Qiao
    Duan, Shuo
    Wu, Jine
    Gong, Zhiyong
    Xu, Lin
    FOOD QUALITY AND SAFETY, 2023, 7
  • [3] Colloidal gold probe-based immunochromatographic assay for the rapid detection of lead ions in water samples
    Tang, Yong
    Zhai, Yi-Fan
    Xiang, Jun-Jian
    Wang, Hong
    Liu, Bin
    Guo, Chang-Wei
    ENVIRONMENTAL POLLUTION, 2010, 158 (06) : 2074 - 2077
  • [4] Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor
    Kuang, Hua
    Xing, Changrui
    Hao, Changlong
    Liu, Liqiang
    Wang, Libing
    Xu, Chuanlai
    SENSORS, 2013, 13 (04): : 4214 - 4224
  • [5] A colloidal gold probe-based silver enhancement immunochromatographic assay for the rapid detection of abrin-a
    Yang Wei
    Li Xiao-bing
    Liu Guo-wen
    Zhang Bing-bing
    Zhang Yi
    Kong Tao
    Tang Jia-jia
    Li Dong-na
    Wang Zhe
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (08): : 3710 - 3713
  • [6] A competitive immunochromatographic assay based on a novel probe for the detection of mercury (II) ions in water samples
    Zhou, Yu
    Zhang, Yuanyuan
    Pan, Fengguang
    Li, Yansong
    Lu, Shiying
    Ren, Honglin
    Shen, Qingfeng
    Li, Zhaohui
    Zhang, Junhui
    Chen, Qijun
    Liu, Zengshan
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (11): : 2534 - 2538
  • [7] A sensitive immunochromatographic assay using colloidal gold-antibody probe for rapid detection of pharmaceutical indomethacin in water samples
    Li, Dawei
    Wei, Shuang
    Yang, Hong
    Li, Yuan
    Deng, Anping
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07): : 2277 - 2280
  • [8] Colloidal gold nanoparticle probe-based immunochromatographic assay for the rapid detection of chromium ions in water and serum samples
    Liu, Xi
    Xiang, Jun-Jian
    Tang, Yong
    Zhang, Xiao-Li
    Fu, Qiang-Qiang
    Zou, Jun-Hui
    Lin, YueHe
    ANALYTICA CHIMICA ACTA, 2012, 745 : 99 - 105
  • [9] Silver nanoparticles capped with carbon dots as a fluorescent probe for the highly sensitive “off–on” sensing of sulfide ions in water
    B. Sinduja
    S. Abraham John
    Analytical and Bioanalytical Chemistry, 2019, 411 : 2597 - 2605
  • [10] Highly sensitive and selective detection of silver ions and silver nanoparticles in aqueous solution using an oligonucleotide-based fluorogenic probe
    Lin, Yen-Hsiu
    Tseng, Wei-Lung
    CHEMICAL COMMUNICATIONS, 2009, (43) : 6619 - 6621