A fast temperature compensation method for digital oscilloscope amplitude calibration

被引:0
|
作者
Huang, Wuhuang [1 ]
Zuo, Zhipeng [1 ]
Zhu, Guibing [1 ]
Chen, Aijun [1 ]
Meng, Jie [2 ]
Qiu, Duyu [1 ]
Pan, Huiqing [1 ]
Li, Chengyang [1 ]
Wang, Houjun [2 ]
机构
[1] Univ Elect Sci & Technol China, Sch Automat Engn, Chengdu, Peoples R China
[2] Univ Elect Sci & Technol China, Shenzhen Inst Adv Study, Shenzhen, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Digital oscilloscope; Amplitude calibration; Fast temperature compensation; Quadratic curve fitting;
D O I
10.1109/AUTOTESTCON47464.2023.10296322
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With the rapid development of modern science and technology, the demand for accurate observation of complex signals is increasing vastly, which makes the digital oscilloscope develops towards a higher sampling rate and resolution. However, the amplitude measurement accuracy of the digital oscilloscope is not only affected by the realization circuit complexity but also by a variety of unstable factors such as temperature in the environment. Therefore, a lot of complex amplitude calibration processes are needed before practical use, and the calibration accuracy is also difficult to reach a stable level. This paper presents a fast temperature compensation method based on quadratic curve fitting for digital oscilloscope amplitude calibration. First, an automatic amplitude calibration system is set up with an oscilloscope to be calibrated, a calibrator and a temperature-humidity test chamber. Then an automatic data recording and processing method based on quadratic curve fitting is proposed, and the specific expressions are given for the calibration process. Finally, the automatic amplitude calibration is realized and verified in the digital oscilloscope with 8GHz bandwidth and 2mV/div similar to 1V/div vertical sensitivity. The test results show that the proposed method can automatically calibrate the amplitude accuracy of 0.5%FS at 0 degrees C similar to 40 degrees C, and the whole process only needs two temperature cycles. This greatly improves the efficiency of amplitude temperature calibration, reduces tedious human work, and provides greater convenience for the accurate measurement of digital oscilloscopes.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A fast baseline and trigger level calibration method in digital oscilloscope
    Yang Kuojun
    Pan Zhixiang
    Shi Jiali
    Ye Peng
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 1058 - 1063
  • [2] A fast TIADC calibration method for 5GSPS digital storage oscilloscope
    Yang, Kuojun
    Wei, Wentao
    Shi, Jiali
    Zhao, Yu
    Huang, Wuhuang
    IEICE ELECTRONICS EXPRESS, 2018, 15 (09):
  • [3] A TIADC mismatch calibration method for digital storage oscilloscope
    Yang Kuojun
    Shi Jiali
    Yang Huizhi
    PROCEEDINGS OF 2017 13TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL 1, 2017, : 379 - 383
  • [4] A fast pulse oscilloscope calibration system
    Deyst, JP
    Paulter, NG
    Daboczi, T
    Stenbakken, GN
    Souders, TM
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 166 - 171
  • [5] Design of automatic calibration in digital oscilloscope
    Wen Weifeng
    Zhao Yijiu
    Yu Zhonghao
    He Hui
    Zhang Shanshan
    PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 79 - 85
  • [6] Fast-pulse oscilloscope calibration system
    Natl Inst of Standards and, Technology, Gaithersburg, United States
    IEEE Trans Instrum Meas, 5 (1037-1041):
  • [7] A fast-pulse oscilloscope calibration system
    Deyst, JP
    Paulter, NG
    Dabóczi, T
    Stenbakken, GN
    Souders, TM
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (05) : 1037 - 1041
  • [8] Timing Skew Calibration Method for TIADC-Based 20 GSPS Digital Storage Oscilloscope
    Yang, Kuojun
    Shi, Jiali
    Tian, Shulin
    Huang, Wuhuang
    Ye, Peng
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2016, 25 (02)
  • [9] Fast Amplitude-Only Measurement Method for Phased Array Calibration
    Long, Rui
    Ouyang, Jun
    Yang, Feng
    Han, Wangwang
    Zhou, Longjian
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2017, 65 (04) : 1815 - 1822
  • [10] Auto-calibration system of digital oscilloscope based IVI
    Li Xunbo
    Yuan Taiwen
    Zhao Ruhe
    Qin Guangxu
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 6463 - 6466