Electrochemical lateral-flow device for rapid COVID-19 antigen-diagnostic testing

被引:21
|
作者
Deenin, Wanwisa [1 ,2 ]
Yakoh, Abdulhadee [2 ,3 ]
Pimpitak, Umaporn [2 ]
Pasomsub, Ekawat [4 ]
Rengpipat, Sirirat [5 ]
Crespo, Gaston A. [6 ,7 ]
Chaiyo, Sudkate [2 ,3 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Program Biotechnol, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Inst Biotechnol & Genet Engn, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Vet Sci, Ctr Excellence Food & Water Risk Anal FAWRA, Dept Vet Publ Hlth, Bangkok, Thailand
[4] Mahidol Univ, Fac Med, Dept Pathol, Ramathibodi Hosp, Bangkok 10400, Thailand
[5] Chulalongkorn Univ, Qualified Diagnost Dev Ctr QDD, Bangkok 10330, Thailand
[6] KTH Royal Inst Technol, Sch Engn Sci Chem Biotechnol & Hlth, Dept Chem, Tekn Ringen 30SE-100 44, Stockholm, Sweden
[7] Univ Catolica San Antonio Murcia, UCAM SENS, UCAM HiTech, Murcia 30107, Spain
关键词
COVID-19; SARS-CoV-2; Antigen test kits; ACE2; Electrochemical detection; Lateral -flow immunosensor; SARS-COV-2;
D O I
10.1016/j.bioelechem.2023.108438
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Antigen test kits (ATK) are extensively utilized for screening and diagnosing COVID-19 because they are easy to operate. However, ATKs exhibit poor sensitivity and cannot detect low concentrations of SARS-CoV-2. Herein, we present a new, highly sensitive, and selective device obtained by combining the principle of ATKs with elec-trochemical detection for COVID-19 diagnosis, which can be quantitatively assessed using a smartphone. An electrochemical test strip (E-test strip) was constructed by attaching a screen-printed electrode inside a lateral -flow device to exploit the remarkable binding affinity of SARS-CoV-2 antigen to ACE2. The ferrocene carboxylic acid attached to SARS-CoV-2 antibody acts as an electroactive species when it binds to SARS-CoV-2 antigen in the sample before it flows continuously to the ACE2-immobilization region on the electrode. Electrochemical-assay signal intensity on smartphones increased proportionally to the concentration of SARS-CoV-2 antigen (LOD = 2.98 pg/mL, under 12 min). Additionally, the application of the single-step E-test strip for COVID-19 screening was demonstrated using nasopharyngeal samples, and the results were consistent with those obtained using the gold standard (RT-PCR). Therefore, the sensor demonstrated excellent performance in assessing and screening COVID-19, and it can be used professionally to accurately verify diagnostic data while remaining rapid, simple, and inexpensive.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Rapid antigen testing in COVID-19 responses
    Garcia-Finana, Marta
    Buchan, Iain E.
    SCIENCE, 2021, 372 (6542) : 571 - 572
  • [2] A Lateral-Flow Device for the Rapid Detection of Scedosporium Species
    Davies, Genna E.
    Thornton, Christopher R.
    DIAGNOSTICS, 2024, 14 (08)
  • [3] Falsification of home rapid antigen lateral flow tests during the COVID-19 pandemic
    Devashish Ray
    Raenhha Dhami
    Jan Lecouturier
    Laura J. McGowan
    Aritra Mukherjee
    Ivo Vlaev
    Michael P. Kelly
    Falko F. Sniehotta
    Scientific Reports, 14
  • [4] Falsification of home rapid antigen lateral flow tests during the COVID-19 pandemic
    Ray, Devashish
    Dhami, Raenhha
    Lecouturier, Jan
    Mcgowan, Laura J.
    Mukherjee, Aritra
    Vlaev, Ivo
    Kelly, Michael P.
    Sniehotta, Falko F.
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [5] Performance of antigen testing for diagnosis of COVID-19: a direct comparison of a lateral flow device to nucleic acid amplification based tests
    Kahn, Maria
    Schuierer, Lukas
    Bartenschlager, Christina
    Zellmer, Stephan
    Frey, Ramona
    Freitag, Marie
    Dhillon, Christine
    Heier, Margit
    Ebigbo, Alanna
    Denzel, Christian
    Temizel, Selin
    Messmann, Helmut
    Wehler, Markus
    Hoffmann, Reinhard
    Kling, Elisabeth
    Roemmele, Christoph
    BMC INFECTIOUS DISEASES, 2021, 21 (01)
  • [6] Performance of antigen testing for diagnosis of COVID-19: a direct comparison of a lateral flow device to nucleic acid amplification based tests
    Maria Kahn
    Lukas Schuierer
    Christina Bartenschlager
    Stephan Zellmer
    Ramona Frey
    Marie Freitag
    Christine Dhillon
    Margit Heier
    Alanna Ebigbo
    Christian Denzel
    Selin Temizel
    Helmut Messmann
    Markus Wehler
    Reinhard Hoffmann
    Elisabeth Kling
    Christoph Römmele
    BMC Infectious Diseases, 21
  • [7] Evaluation of COVID-19 antigen rapid diagnostic tests for self-testing in Lesotho and Zambia
    Bresser, Moniek
    Erhardt, Rahel Milena
    Shanaube, Kwame
    Simwinga, Musonda
    Mahlatsi, Palesa Agnes
    Belus, Jennifer
    Schaap, Albertus
    Amstutz, Alain
    Gachie, Thomas
    Glass, Tracy Renee
    Kangololo, Bxyn
    'Mota, John
    Floyd, Sian
    Katende, Bulemba
    Klinkenberg, Eveline
    Ayles, Helen
    Reither, Klaus
    Ruperez, Maria
    PLOS ONE, 2024, 19 (02):
  • [8] Diagnostic Performance of Rapid Antigen Testing for SARS-CoV-2: The COVid-19 AntiGen (COVAG) study
    Wertenauer, Christoph
    Brenner Michael, Geovana
    Dressel, Alexander
    Pfeifer, Caroline
    Hauser, Ulrike
    Wieland, Eberhard
    Mayer, Christian
    Mutschmann, Caren
    Roskos, Martin
    Wertenauer, Hans-Joerg
    Moissl, Angela P.
    Lorkowski, Stefan
    Maerz, Winfried
    FRONTIERS IN MEDICINE, 2022, 9
  • [9] Development of an immunochromatographic lateral-flow device for rapid serodiagnosis of invasive aspergillosis
    Thornton, Christopher R.
    CLINICAL AND VACCINE IMMUNOLOGY, 2008, 15 (07) : 1095 - 1105
  • [10] Rapid Antigen Diagnostics as Frontline Testing in the COVID-19 Pandemic
    Xu, Jiang
    Kerr, Liam
    Jiang, Yue
    Suo, Wenhao
    Zhang, Lei
    Lao, Taotao
    Chen, Yuxin
    Zhang, Yan
    SMALL SCIENCE, 2022, 2 (08):