A study on energy window-based scatter correction methods in 99mTc and 123I imaging

被引:2
|
作者
Can, M. [1 ,2 ]
Karadeniz, O. [2 ,3 ]
Kaya, G. Capa [2 ,4 ]
Ertay, T. [2 ,4 ]
机构
[1] Dokuz Eylul Univ, Vocat Sch Hlth Serv, Program Nucl Med Tech, Izmir, Turkiye
[2] Dokuz Eylul Univ, Inst Hlth Sci, Dept Med Phys, Izmir, Turkiye
[3] Dokuz Eylul Univ, Fac Sci, Dept Phys, Izmir, Turkiye
[4] Dokuz Eylul Univ, Fac Med, Dept Nucl Med, Izmir, Turkiye
关键词
Compton imaging; Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Image reconstruction in medical imaging; Medical-image reconstruction methods and algorithms; computer-aided diagnosis; DOWNSCATTER CORRECTION; COLLIMATOR CHOICE; I-123; COMPENSATION; ISOTOPE;
D O I
10.1088/1748-0221/18/10/P10009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Tc-99m and I-123 are radionuclides commonly used for diagnostic examination in nuclear medicine. Detection of the scattered photons by the Compton interactions in the photopeak energy window is a factor affecting the image quality. DEW and TEW scatter correction methods are used to improve the image quality degrade by Compton scattered photons. In the study, planar and SPECT images of sphere, rod and cardiac phantom containing different activities were acquired with a gamma camera system. DEW/TEW corrected and uncorrected images for Tc-99m/I-123 were evaluated qualitatively and quantitatively. Both for planar and SPECT images, the DEW and TEW scatter correction methods were found to improve the image quality at varying rates.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Model-based correction for scatter and tailing effects in simultaneous 99mTc and 123I imaging for a CdZnTe cardiac SPECT camera
    Holstensson, M.
    Erlandsson, K.
    Poludniowski, G.
    Ben-Haim, S.
    Hutton, B. F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08): : 3045 - 3063
  • [2] Scatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging
    Bai, Jingming
    Hashimoto, Jun
    Ogawa, Koichi
    Nakahara, Tadaki
    Suzuki, Takayuki
    Kubo, Atsushi
    ANNALS OF NUCLEAR MEDICINE, 2007, 21 (01) : 25 - 32
  • [3] A Phantom Study on Compton Scatter Correction Methods in 99mTc Imaging
    Can, M.
    Karadeniz, O.
    Ertay, T.
    Kaya, G. Capa
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S248 - S248
  • [4] Correction for scatter and cross-talk in simultaneous 99mTc and 123I imaging for a CZT-based cardiac SPECT scanner
    Holstensson, M.
    Erlandsson, K.
    Kacperski, K.
    Ben-Haim, S.
    Bross, S.
    Hutton, B. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S205 - S205
  • [5] Cross-talk correction for dual radionuclide brain imaging with 99mTc and 123I
    Erlandsson, K
    Visvikis, D
    Waddington, WA
    Costa, DC
    Jarritt, P
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1561 - 1565
  • [6] Physical phantom evaluation of simultaneous 99mTc/123I SPECT imaging
    Yang, Bang-Hung
    Wang, Shyh-Jen
    Lee, Jhih-Shian
    Jan, Meei-Ling
    Chang, Chia-Jung
    Chen, Jyh-Cheng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 744 - 746
  • [7] Scatter correction in 99mTc SPECT by energy window narrowing and Monte Carlo simulation
    Arvola, S.
    Seppanen, M.
    Noponen, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S658 - S658
  • [8] Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I
    Tunninen, V.
    Kauppinen, T.
    Eskola, H.
    EMBEC & NBC 2017, 2018, 65 : 245 - 249
  • [9] Optimization of acquisition energy windows in simultaneous 99mTc/123I brain SPECT
    Du, Y
    Frey, EC
    Wang, WT
    Tsui, BMW
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1018 - 1022
  • [10] Optimization of acquisition energy windows in simultaneous 99mTc/123I brain SPECT
    Du, Y
    Frey, EC
    Wang, WT
    Tsui, BMW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1556 - 1561