A comparison study of the filtration behavior of air filtering materials of masks against inert and biological particles

被引:12
|
作者
He, Weidong [1 ,2 ,3 ]
Yue, Yang [2 ,3 ]
Guo, Yinghe [2 ,3 ,4 ]
Zhao, Yi-Bo [2 ,3 ]
Liu, Jingxian [1 ]
Wang, Jing [2 ,3 ]
机构
[1] Northeastern Univ, Filter Test Ctr, Shenyang 110819, Liaoning, Peoples R China
[2] Swiss Fed Inst Technol, Inst Environm Engn, CH-8093 Zurich, Switzerland
[3] Empa, Lab Adv Analyt Technol, CH-8600 Dubendorf, Switzerland
[4] Shenyang Ligong Univ, Sch Environm & Chem Engn, Shenyang 110159, Peoples R China
基金
美国国家科学基金会;
关键词
Filtration efficiency; Inert particle; Bioaerosol; Electret filter; Aerosol generation; DIELECTRIC-CONSTANT; SHAPE; SIZE; BIOAEROSOLS; RESPIRATOR; EFFICIENCY; TRANSPORT; AEROSOLS;
D O I
10.1016/j.seppur.2023.123472
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Inert particles are widely used as surrogates for biological particles in filtration tests. However, there is always a concern that the different physical properties between inert particles and biological particles may affect the filtration efficiencies of filter media. In the present study, the inert particles, e.g. NaCl and polystyrene latex (PSL), and biological particles, e.g. E.coli, B.sublitis, bovine serum albumin (BSA), and endotoxin, were used to evaluate the filtration efficiencies of the filtering materials of a surgical mask and a N95-rated respirator. The results showed that the difference in the filtration efficiencies of the N95-rated respirator for the tested inert particles and biological particles was smaller than 0.02%. The filtration efficiency of the surgical mask for PSL particles was lower than that for E.coli and B.subtilis particles with the same aerodynamic diameter because of the larger interception lengths of E.coli and B.subtilis particles. The average filtration efficiencies of the surgical mask for the tested NaCl particles and biological particles in the size range of 20-600 nm were similar. For the monodisperse particles, the filtration efficiency of the surgical mask for NaCl, BSA and endotoxin particles in the size range of 50-250 nm decreased in the above order due to the different shapes, dielectric properties, and multiply-charged fractions of the particles. The surgical mask presented the highest filtration efficiency for BSA particles and the lowest filtration efficiency for NaCl particles when the particle size was larger than 300 nm, which could be related to the difference in the electrostatic deposition and bounce probabilities. The present work revealed that the influence of several particle characteristics such as shape, dielectric property, and charge state on filtration efficiency should be considered when using common inert particles to replace biological particles to measure efficiencies of air filters.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Comparison of the Filtration Efficiency of Different Face Masks Against Aerosols
    Stahl, Connor
    Frederick, Kevin
    Chaudhary, Sachin
    Morton, Christopher J.
    Loy, Douglas
    Muralidharan, Krishna
    Sorooshian, Armin
    Parthasarathy, Sairam
    FRONTIERS IN MEDICINE, 2021, 8
  • [2] The use of fibrous face masks as a barrier against infectious biological airborne particles
    Maduna, Lebo
    Patnaik, Asis
    JOURNAL OF INDUSTRIAL TEXTILES, 2023, 53
  • [3] HOSPITAL MASKS: THEIR BACTERIAL FILTERING EFFICIENCY AND RESISTANCE TO AIR FLOW A COMPARATIVE STUDY
    Rooks, Roland
    Cralley, Lewis J.
    Barnes, M. E.
    PUBLIC HEALTH REPORTS, 1941, 56 (28) : 1411 - 1419
  • [4] Comparison of flame inception behavior of liquid nitromethane in inert and air environments
    Schwind, Rachel A.
    Sinrud, Joshua B.
    Fuller, Casey C.
    Klassen, Michael S.
    Walker, Robert A.
    Goldsmith, C. Franklin
    COMBUSTION AND FLAME, 2022, 241
  • [5] Comparison of flame inception behavior of liquid nitromethane in inert and air environments
    Schwind, Rachel A.
    Sinrud, Joshua B.
    Fuller, Casey C.
    Klassen, Michael S.
    Walker, Robert A.
    Goldsmith, C. Franklin
    Combustion and Flame, 2022, 241
  • [6] Electrospun Nanofibre Filtration Media to Protect against Biological or Nonbiological Airborne Particles
    Karabulut, Fabrice N. H.
    Hofler, Gunther
    Chand, Naveen Ashok
    Beckermann, Gareth W.
    POLYMERS, 2021, 13 (19)
  • [7] Simple Respiratory Protection-Evaluation of the Filtration Performance of Cloth Masks and Common Fabric Materials Against 20-1000 nm Size Particles
    Rengasamy, Samy
    Eimer, Benjamin
    Shaffer, Ronald E.
    ANNALS OF OCCUPATIONAL HYGIENE, 2010, 54 (07): : 789 - 798
  • [8] Pretreated household materials carry similar filtration protection against pathogens when compared with surgical masks
    Carnino, Jonathan M.
    Ryu, Sunhyo
    Ni, Kareemah
    Jin, Yang
    AMERICAN JOURNAL OF INFECTION CONTROL, 2020, 48 (08) : 883 - 889
  • [9] Explosions of methane/air/nanoparticles mixtures: Comparison between carbon black and inert particles
    Torrado, David
    Buitrago, Valentina
    Glaude, Pierre-Alexandre
    Dufaud, Olivier
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2017, 110 : 77 - 88
  • [10] Experimental Study of Filtration Materials Used in the Car Air Intake
    Dziubak, Tadeusz
    Dziubak, Sebastian Dominik
    MATERIALS, 2020, 13 (16)