A Pilot Study to Assess the Performance of Phase-Sensitive Breast Tomosynthesis

被引:3
|
作者
Fajardo, Laurie L. [1 ]
Hillis, Stephen L. [2 ]
Zheng, Bin [3 ,4 ]
Wong, Molly Donovan [3 ,4 ]
Ghani, Muhammad U. [3 ,4 ]
Omoumi, Farid H. [3 ,4 ]
Li, Yuhua [3 ]
Jenkins, Peter [1 ]
Peterson, Michael E. [1 ,4 ]
Wu, Xizeng [5 ]
Liu, Hong [3 ,4 ]
机构
[1] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USA
[2] Univ Iowa, Dept Radiol & Biostat, Iowa City, IA USA
[3] Univ Oklahoma, Adv Med Imaging Ctr, Norman, OK 73019 USA
[4] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
[5] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL USA
关键词
DORFMAN-BERBAUM-METZ; CONTRAST; ROC; MAMMOGRAPHY; RETRIEVAL;
D O I
10.1148/radiol.213198
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: A new modality, phase-sensitive breast tomosynthesis (PBT), may have similar diagnostic performance to conventional breast tomosynthesis but with a reduced radiation dose.Purpose: To perform a pilot study of the performance of a novel PBT system compared with conventional digital breast tomosynthesis (DBT) in patients undergoing additional diagnostic imaging workup for breast lesions.Materials and Methods: In a prospective study from June 2020 to March 2021, participants with suspicious breast lesions detected at screening DBT or MRI were recruited for additional PBT imaging before additional diagnostic workup or biopsy. In this pilot study, nine radiologists independently evaluated image quality and assessed the likelihood of lesion malignancy by retrospectively evaluating DBT and PBT images in two separate reading sessions. Image quality was rated subjectively using a Likert scale from 1 to 5. Areas under the receiver operating characteristic curve (AUCs) were used to compare the lesion classification (malignant vs benign) performance of the radiologists.Results: Images in 50 patients (mean age, 56 years +/- 12 [SD]; 49 women) with 52 evaluable lesions (28 malignant) were assessed. For image appearance and general feature visibility, DBT images had a higher total mean image quality score (3.8) than PBT images (2.9), with P <.002 for each comparison. For classification of lesions as benign or malignant, the AUCs were 0.74 for both PBT and DBT. PBT images were acquired at a 24% mean radiation dose reduction (mean, 1.78 mGy vs 2.34 mGy for DBT; P < .001).Conclusion: The phase-sensitive breast tomosynthesis system had a 24% lower mean radiation dose compared with digital breast tomo-synthesis, although with lower image quality. Diagnostic performance of the system remains to be determined in larger studies.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Phase-Sensitive Breast Tomosynthesis May Address Shortcomings of Digital Breast Tomosynthesis
    Gao, Yiming
    Moy, Linda
    RADIOLOGY, 2023, 306 (02)
  • [2] Assessing detectability improvement of a self-supervised noise reduction algorithm for phase-sensitive breast tomosynthesis phantom images
    Nelson, Jared
    Chen, Xuxin
    Li, Yuhua
    Omoumi, Farid H.
    Wong, Molly Donovan
    Liu, Hong
    BIOPHOTONICS AND IMMUNE RESPONSES XIX, 2024, 12843
  • [3] Digital breast tomosynthesis: A pilot observer study
    Good, Walter F.
    Abrams, Gordon S.
    Catullo, Victor J.
    Chough, Denise M.
    Ganott, Marie A.
    Hakim, Christiane M.
    Gur, David
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) : 865 - 869
  • [4] HIGH-PERFORMANCE PHASE-SENSITIVE DETECTOR
    MARZETTA, LA
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1971, IM20 (04) : 296 - &
  • [5] A HIGH-PERFORMANCE PHASE-SENSITIVE DETECTOR
    FAULKNER, EA
    HARDING, DW
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (02): : 97 - &
  • [6] Study of Phase-Sensitive Heterodyne Locking
    Yang, Peng
    Ke, Xuezhi
    Zhang, Lei
    Hu, Guozhen
    TWELFTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2021), 2021, 12057
  • [7] NEW HIGH-PERFORMANCE PHASE-SENSITIVE DETECTOR
    GRIMBLEBY, JB
    HARDIN, DW
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1971, 4 (NDEC): : 941 - +
  • [8] Experimental study of a phase-sensitive heterodyne detector
    Fan, Heng
    He, Dechao
    Feng, Sheng
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2015, 32 (10) : 2172 - 2177
  • [9] Imaging study of a phase-sensitive breast-CT system in continuous acquisition mode
    Delogu, P.
    Golosio, B.
    Fedon, C.
    Arfelli, F.
    Bellazzini, R.
    Brez, A.
    Brun, F.
    Di Lillo, F.
    Dreossi, D.
    Mettivier, G.
    Minuti, M.
    Oliva, P.
    Pichera, M.
    Rigon, L.
    Russo, P.
    Sarno, A.
    Spandre, G.
    Tromba, G.
    Longo, R.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [10] PHASE-SENSITIVE RECTIFIER
    POPOV, VS
    DZHANGOZIN, AD
    MEASUREMENT TECHNIQUES USSR, 1982, 25 (01): : 80 - 83