Numerical computation of pulsatile hemodynamics and diagnostic concern of coronary bifurcated artery flow for Newtonian and non-Newtonian fluid

被引:1
|
作者
Uddin, Md. Jashim [1 ,2 ,3 ]
Bangalee, M. Z. I. [1 ,2 ]
Ferdows, M. [1 ,2 ]
机构
[1] Univ Dhaka, Dept Appl Math, Dhaka 1000, Bangladesh
[2] Univ Dhaka, Dept Appl Math, Res Grp Fluid Flow Modeling & Simulat, Dhaka 1000, Bangladesh
[3] Noakhali Sci & Technol Univ, Dept Appl Math, Noakhali 3814, Bangladesh
关键词
CFD; Pulsatile flow; Pressure drop; Recirculation length; Lesion flow coefficient; Importance factor(IFc); ENDOTHELIAL SHEAR-STRESS; BLOOD-FLOW; IN-VIVO; STENOSIS; ATHEROSCLEROSIS; COEFFICIENT; PROGRESSION; SIMULATION; DISEASE;
D O I
10.1016/j.heliyon.2023.e17533
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Atherosclerotic with the high occurrence of plaque formation due to stenosis has attracted wide attention among researchers. The left coronary artery has been studied in two-dimensional and in three-dimensional (3D) bifurcation as the models of blood flow through Newtonian and nonNewtonian fluids to better understand the physical mechanism. The computational Fluid Dynamics (CFD) technique is incorporated in COMSOL Multiphysics and then it is justified by satisfactory validation. It is found that the Newtonian model shows larger recirculation zones than non-Newtonian does. The present study also focuses on the evaluations of the lesion of diagnostic and the coefficient of pressure drop assessments on the basis of the diagnostic parameter's critical values affected by the rheological model. Nevertheless, the leading concentration of the subsisting investigation works is confined to the change of importance factor (IFc) affected by arterial blockage. But the IFc of non-Newtonian fluid for 3D left coronary artery bifurcation model decreases with increasing bifurcation angle and the time-averaged inlet pressure is the least for smaller bifurcation angles. The current research further concentrates that the flow separation length reduces with developing bifurcation angle in bifurcated geometry. It is significant to mention that non-Newtonian blood flow model incorporating hemodynamic and diagnostic parameters has great impacts on instantaneous flow systems.
引用
收藏
页数:27
相关论文
共 50 条
  • [1] Multiphase non-Newtonian effects on pulsatile hemodynamics in a coronary artery
    Kim, Yong Hyun
    VandeVord, Pamela J.
    Lee, Joon Sang
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2008, 58 (07) : 803 - 825
  • [2] Modeling analysis of pulsatile non-Newtonian blood flow in a renal bifurcated artery with stenosis
    Hamidah M.A.
    Hossain S.M.C.
    International Journal of Thermofluids, 2024, 22
  • [3] Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation
    Yubo Fan
    Wentao Jiang
    Yuanwen Zou
    Jinchuan Li
    Junkai Chen
    Xiaoyan Deng
    Acta Mechanica Sinica, 2009, 25 : 249 - 255
  • [4] Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation
    Y. Fan X. Deng School of Biological Science and Medical Engineering
    Acta Mechanica Sinica, 2009, (02) : 249 - 255
  • [5] Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation
    Fan, Yubo
    Jiang, Wentao
    Zou, Yuanwen
    Li, Jinchuan
    Chen, Junkai
    Deng, Xiaoyan
    ACTA MECHANICA SINICA, 2009, 25 (02) : 249 - 255
  • [6] Non-Newtonian Flow of Blood in a Catheterized Bifurcated Stenosed Artery
    Misra, Jagadis Chandra
    Shit, Gopal Chandra
    Pramanik, Ranjan
    JOURNAL OF BIONIC ENGINEERING, 2018, 15 (01) : 173 - 184
  • [7] Non-Newtonian flow of blood in a catheterized bifurcated stenosed artery
    Jagadis Chandra Misra
    Gopal Chandra Shit
    Ranjan Pramanik
    Journal of Bionic Engineering, 2018, 15 : 173 - 184
  • [8] NUMERICAL-ANALYSIS OF PULSATILE FLOW OF A NON-NEWTONIAN FLUID IN AN ELASTIC TUBE
    PERKTOLD, K
    HILBERT, D
    SIEKMANN, J
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1992, 72 (05): : T373 - T377
  • [9] Computational Analysis of Non-Newtonian Blood Flow through Bifurcated Coronary Artery: Insights into Hemodynamics and Wall Shear Stress
    Buradi, Abdulrajak
    Khan, Md Yousuf Ahmed
    Tamilselvan, Sanjaytharan
    Kapilan, N.
    JOURNAL OF POLYMER & COMPOSITES, 2023, 11 : 160 - 168
  • [10] Non-Newtonian pulsatile flow through an artery with two stenosis
    Kumar, Gaurav
    Kumar, Hitesh
    Mandia, Kabir
    Zunaid, M.
    Ansari, N. A.
    Husain, A.
    MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 10793 - 10798